Top-up operation at Pohang Light Source-II

被引:17
|
作者
Hwang, I. [1 ]
Huang, J. Y. [1 ]
Kim, M. [1 ]
Lee, B. -J. [1 ]
Kim, C. [1 ]
Choi, J. -Y. [1 ]
Kim, M. -H. [1 ]
Lee, H. S. [1 ]
Moon, D. [1 ]
Lee, E. H. [1 ]
Kim, D. -E. [1 ]
Nam, S. H. [1 ]
Shin, S. [1 ]
Cho, Moohyun [2 ]
机构
[1] Pohang Accelerator Lab, Pohang 790834, Kyungbuk, South Korea
[2] POSTECH, Dept Phys, Pohang 790834, Kyungbuk, South Korea
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 05期
关键词
549.3; Others; including Bismuth; Boron; Cadmium; Cobalt; Mercury; Niobium; Selenium; Silicon; Tellurium and Zirconium - 932.1.1 Particle Accelerators;
D O I
10.1063/1.4878256
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
After three years of upgrading work, PLS-II (S. Shin, Commissioning of the PLS-II, JINST, January 2013) is now successfully operating. The top-up operation of the 3 GeV linear accelerator had to be delayed because of some challenges encountered, and PLS-II was run in decay mode at the beginning in March 2012. The main difficulties encountered in the top-up operation of PLS-II are different levels between the linear accelerator and the storage ring, the 14 narrow gap in-vacuum undulators in operation, and the full energy injection by 3 GeV linear accelerator. Large vertical emittance and energy jitter of the linac were the major obstacles that called for careful control of injected beam to reduce beam loss in the storage ring during injection. The following measures were taken to resolve these problems: (1) The high resolution Libera BPM (see http://www.i-tech.si) was implemented to measure the beam trajectory and energy. (2) Three slit systems were installed to filter the beam edge. (3) De-Qing circuit was applied to the modulator system to improve the energy stability of injected beam. As a result, the radiation by beam loss during injection is reduced drastically, and the top-up mode has been successfully operating since 19th March 2013. In this paper, we describe the experimental results of the PLS-II top-up operation and the improvement plan. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Reduction of RF accelerating voltage of Pohang Light Source-II superconducting RF cavity for stable top-up mode operation
    Joo, Y.
    Yu, I.
    Park, I.
    Chun, M. H.
    Sohn, Y.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [2] Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA
    Joo, Youngdo
    Yu, Inha
    Park, Insoo
    Chun, Myunghwan
    Lee, Byung-Joon
    Hwang, Ilmoon
    Ha, Taekyun
    Shin, Seunghwan
    Sohn, Younguk
    [J]. JOURNAL OF APPLIED PHYSICS, 2014, 116 (23)
  • [3] Improvement of the Micro-pulse Structure for Top-up Operation at the Pohang Light Source
    Hwang, Ilmoon
    Kim, Changbum
    Son, Yoon-Kyoo
    Chun, Myung-Hwan
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 590 - 593
  • [4] A preliminary study of beam instabilities in top-up operation at Taiwan light source
    Chou, P. J.
    Chang, H. P.
    Hsu, K. T.
    Hu, K. H.
    Kuo, C. C.
    Luo, G. H.
    Wang, M. H.
    [J]. 2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 244 - 246
  • [5] Radiological implications of top-off operation at national synchrotron light source-II
    Job, P. K.
    Casey, W. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 (01): : 15 - 21
  • [6] Overview of top-up injection at Taiwan light source
    Luo, G. H.
    Chang, H. P.
    Chang, J. C.
    Chen, C. T.
    Chen, Jenny
    Chen, J. R.
    Fann, C. S.
    Hsu, K. T.
    Hwang, C. S.
    Kuo, C. C.
    Liu, K. B.
    Liu, Y. C.
    Sheu, R. J.
    Ueng, T. S.
    Wang, D. J.
    Wang, M. H.
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 13 - +
  • [7] Full Energy Injection and Top-up Operation at UVSOR-II
    Katoh, Masahiro
    Adachi, Masahiro
    Zen, Heishun
    Yamazaki, Jun-ichiro
    Hayashi, Kenji
    Mochihashi, Akira
    Shimada, Miho
    Hosaka, Masahito
    [J]. SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 531 - 534
  • [8] Energy-efficient operation of a booster RF system for Taiwan light source operated in top-up mode
    Yeh, Meng-Shu
    Wang, Chaoen
    Chang, Lung-Hai
    Chung, Fu-Tsai
    Yu, Tsung-Chi
    Lin, Ming-Chyuan
    Chen, Ling-Jhen
    Yang, Tz-Te
    Chang, Mei-Hsia
    Lin, Yu-Han
    Tsai, Ming-Hsun
    Lo, Chih-Hung
    Liu, Zong-Kai
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 775 : 46 - 53
  • [9] Multimodal X-ray probe station at 9C beamline of Pohang Light Source-II
    Ham, Daseul
    Lee, Su Yong
    Choi, Sukjune
    Oh, Ho Jun
    Noh, Do Young
    Kang, Hyon Chol
    [J]. Journal of Synchrotron Radiation, 2022, 29 : 1114 - 1121
  • [10] Observation of the Talbot Effect at Beamline 6C Bio Medical Imaging of the Pohang Light Source-II
    Youngju Kim
    Seung Wook Lee
    Jae-Hong Lim
    [J]. Journal of the Korean Physical Society, 2019, 74 : 935 - 940