Rapid and sensitive liquid chromatography-tandem mass spectrometric method for the quantitation of metformin in human plasma

被引:88
|
作者
Wang, YW
Tang, YB
Gu, JK [1 ]
Fawcett, JP
Bai, X
机构
[1] Jilin Univ, Res Ctr Drug Metab, Changchun 130023, Peoples R China
[2] Univ Otago, Sch Pharm, Dunedin, New Zealand
基金
中国国家自然科学基金;
关键词
metformin;
D O I
10.1016/j.jchromb.2004.05.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS-MS) method for the determination of metformin in human plasma using phenformin as internal standard has been developed and validated. Sample preparation of plasma involved acidification with acetic acid, deproteination with acetonitrile and washing with dichloromethane. Samples were then analyzed by HPLC on a short Nucleosil C-18 column (5 mum, 50 mm x 4.6 turn i.d.) using a mobile phase consisting of acetonitrile:methanol: 10 mM ammonium acetate pH 7.0 (20:20:60, v/v/v) delivered at 0.65 ml/min. Detection was performed using an Applied Biosystems Sciex API 4000 mass spectrometer set at unit resolution in the multiple reaction monitoring (MRM) mode. Atmospheric pressure chemical ionization (A-PCI) was used for ion production. The assay was linear over the range 1-2000 ng/ml with intra- and inter-day precision of <8.6% and accuracy in the range 91-110%. The limit of detection was 250 pg/ml in plasma. The method was successfully applied to a clinical pharmacokinetic study of an extended-release tablet of metformin hydrochloride (500 mg) administered as a single oral dose. (C) 2004 Elsevier B.V. All fights reserved.
引用
收藏
页码:215 / 219
页数:5
相关论文
共 50 条
  • [1] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of domperidone in human plasma
    Smit, MJ
    Sutherland, FCW
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 949 (1-2) : 65 - 70
  • [2] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of colchicine in human plasma
    Jiang, Yao
    Wang, Jiang
    Wang, Yingwu
    Li, Hao
    Fawcett, J. Paul
    Gu, Jingkai
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 564 - 568
  • [3] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of levodropropizine in human plasma
    Tang, YB
    Zhao, LM
    Wang, YW
    Fawcett, JP
    Gu, JK
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 185 - 189
  • [4] Sensitive and specific liquid chromatography-tandem mass spectrometric method for the quantitation of dexmedetomidine in pediatric plasma
    Lee, James I.
    Su, Felice
    Shi, Heng
    Zuppa, Athena F.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 195 - 201
  • [6] Determination of metformin in human plasma by liquid chromatography-tandem mass spectrometric assay
    Wang, J
    Wang, YW
    Gu, JK
    Wu, Y
    Wang, Y
    [J]. CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2005, 21 (02) : 246 - 250
  • [7] Rapid determination of metformin in human plasma by liquid chromatography-tandem mass spectrometry method
    Chen, XY
    Gu, Q
    Qiu, F
    Zhong, DF
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02): : 377 - 381
  • [8] Sensitive, Accurate and Simple Liquid Chromatography-Tandem Mass Spectrometric Method for the Quantitation of Amphotericin B in Human or Minipig Plasma
    Qin, WeiGe
    Tao, Hui
    Chen, Yoryu
    Chen, Zhaoyuan
    Wu, Nian
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (07) : 636 - 643
  • [9] Pentafluorophenylprophyl Ligand-based Liquid Chromatography-Tandem Mass Spectrometric Method for Rapid and Reproducible Determination of Metformin in Human Plasma
    Yang, Jeong Soo
    Oh, Hyeon Ju
    Jung, Jin Ah
    Kim, Jung-Ryul
    Kim, Tae-Eun
    Ko, Jae-Wook
    Lee, Soo-Youn
    Huh, Wooseong
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (11) : 3284 - 3288
  • [10] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the estimation of nicorandil in human plasma
    Bhatt, Jignesh
    Jangid, Arvind
    Shah, Bhavin
    Shetty, Raghavendra
    Kambli, Sandeep
    Subbaiah, Gunta
    Singh, Sadhana
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (09) : 864 - 869