Two-year Clinical Evaluation of Self-etching Adhesives in Posterior Restorations

被引:0
|
作者
Perdigao, Jorge [1 ]
Dutra-Correa, Maristela [2 ]
Anauate-Netto, Camillo [3 ,4 ]
Castilhos, Natalia [4 ]
Carmo, Andre R. P.
Lewgoy, Hugo R. [4 ]
Amore, Ricardo [3 ]
Cordeiro, Hiram J. D. [5 ]
机构
[1] Univ Minnesota, Dept Restorat Sci, Div Operat Dent, Minneapolis, MN 55455 USA
[2] Univ Sao Paulo, Phys Inst Sao Carlos, Sao Carlos, SP, Brazil
[3] Univ Bandeirante Sao Paulo, Res Grp Dent, Sao Paulo, SP, Brazil
[4] Univ Mogi das Cruzes, Dept Operat Dent, Mogi Das Cruzes, SP, Brazil
[5] UNIBAN Sao Paulo, Dept Operat Dent, Sao Paulo, SP, Brazil
来源
JOURNAL OF ADHESIVE DENTISTRY | 2009年 / 11卷 / 02期
关键词
clinical trial; dental bonding; self-etching; MICROTENSILE BOND STRENGTH; IN-ONE ADHESIVES; ONE-STEP; FUNCTIONAL MONOMERS; DENTIN; ENAMEL; SYSTEMS; PERFORMANCE; PRIMER; SPECTRUM;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the 2-year clinical performance of three self-etching adhesives and one etch-and-rinse adhesive (control) in posterior composite restorations. Materials and Methods: Upon approval by the Institutional Review Board, 121 restorations were inserted in 38 subjects. The adhesives were applied as per manufacturers' instructions. Preparations were restored with a nanofilled composite resin (Filtek Supreme, 3M ESPE) and evaluated at baseline, 6 months, 1 year, and 2 years. Statistical analyses included the McNemar and the Mann-Whitney non-parametric tests (p < 0.05). Results: At 2 years, 91 out of 121 restorations were evaluated using the USPHS modified criteria. The number of alpha ratings decreased significantly from baseline to 2 years for Adper Prompt L-Pop, Clearfil S-3 Bond, and iBond in the categories color match, marginal staining, and marginal adaptation. For One-Step Plus, only marginal staining was significantly worse at 2 years than at baseline. Postoperative sensitivity to air improved significantly for One-Step Plus at 2 years, but this improvement was already detected at 1 year. When the 2-year evaluation criteria were pooled by pairs of adhesives, One-Step Plus resulted in a significantly greater number of alfa ratings for marginal adaptation than the other three adhesives. On the other hand, iBond resulted in a significantly lower number of alfa ratings than any of the other 3 adhesives for color match and marginal staining. Adper Prompt L-Pop, Clearfil S3 Bond, and One-Step Plus resulted in a statistically similar number of alfa ratings for marginal staining and color match. There were no significant differences in any of the evaluation criteria between Clearfil S3 Bond and Adper Prompt L-Pop. Conclusion: Only One-Step Plus, the etch-and-rinse adhesive, resulted in good marginal adaptation at 2 years. One of the self-etching adhesives, iBond, resulted in unacceptable clinical performance.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 50 条
  • [1] Two-year Randomized Clinical Trial of Self-etching Adhesives and Selective Enamel Etching
    Pena, C. E.
    Rodrigues, J. A.
    Ely, C.
    Giannini, M.
    Reis, A. F.
    [J]. OPERATIVE DENTISTRY, 2016, 41 (03) : 249 - 257
  • [2] Two-year clinical evaluation of a self-etching primer/adhesive in posterior composites.
    Denehy, G
    Cobb, D
    Bouschlicher, M
    Vargas, M
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : A80 - A80
  • [3] One year clinical evaluation of two self-etching adhesives.
    Kiremitci, A
    Gokalp, S
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : 523 - 523
  • [4] Two-year Clinical Performance of Self-etching Adhesive Systems in Composite Restorations of Anterior Teeth
    Barcellos, D. C.
    Batista, G. R.
    Silva, M. A.
    Pleffken, P. R.
    Rangel, P. M.
    Fernandes, V. V. B., Jr.
    Di Nicolo, R.
    Torres, C. R. G.
    [J]. OPERATIVE DENTISTRY, 2013, 38 (03) : 258 - 266
  • [5] Two-year bonding durability of self-etching adhesives to enamel and dentin.
    Ikemura, K
    Shinno, K
    Fujii, A
    Kimoto, FK
    Kouro, Y
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : A160 - A160
  • [6] Two-year clinical performance of two one-step self-etching adhesives in the restoration of cervical lesions
    Schattenberg, A.
    Werling, U.
    Willershausen, B.
    Ernst, C. -P.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2008, 12 (03) : 225 - 232
  • [7] Two-year clinical performance of two one-step self-etching adhesives in the restoration of cervical lesions
    A. Schattenberg
    U. Werling
    B. Willershausen
    C.-P. Ernst
    [J]. Clinical Oral Investigations, 2008, 12 : 225 - 232
  • [8] Two-year Water Degradation of Self-etching Adhesives Bonded to Bur Ground Enamel
    Abdalla, A. I.
    Feilzer, A. J.
    [J]. OPERATIVE DENTISTRY, 2009, 34 (06) : 732 - 740
  • [9] Microleakage evaluation restorations in posterior teeth restorations hybridized with self-etching adhesive after storage
    do Couto, Aline Maria
    Alevato, Allice Banni
    de Andrade, Carolina Oliveira
    Devito, Karina Lopes
    Salvio, Luciana Andrea
    [J]. REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2016, 57 (01): : 46 - 50
  • [10] Two-year clinical evaluation of direct and indirect composite restorations in posterior teeth
    Scheibenbogen-Fuchsbrunner, A
    Manhart, J
    Kremers, L
    Kunzelmann, KH
    Hickel, R
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (04): : 391 - 397