Research on an Accident of 500 kV Gas Insulated Transmission Line

被引:2
|
作者
Xiong, Hao [1 ]
Jiang, Hao [1 ]
Zhou, Bin [1 ]
Zhou, Gang [1 ]
机构
[1] Chongqing Elect Power Maintenance Branch, Chongqing 400014, Peoples R China
来源
关键词
Gas insulated transmission lines; SF6; gas; Free metal particle defect;
D O I
10.4028/www.scientific.net/AMM.492.178
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Gas insulated transmission line (GIL) is increasingly being utilized in the power system because of its advantages, such as large transportation capacity, no insulation ageing, low loss, and low electromagnetic radiation. However, even GIL equipment in operation can go wrong under the influence of various factors. This paper is an in-depth analysis on a 500kV GIL fault resulting in the tripping operation of a substation chief transformer. The causes of the accident are discussed from several aspects, such as insulation defect, design of gas inlet port, and effect of temperature on the water in the GIL. Some suggestions are given for the structure design, manufacture, installation, and operation of GIL.
引用
收藏
页码:178 / 181
页数:4
相关论文
共 50 条
  • [1] CONSTRUCTION OF COMPACT 500 kV GAS INSULATED TRANSMISSION LINE.
    Uchida, Keiji
    Yamada, Kazuo
    Kazama, Yohji
    Itoi, Hiroshi
    Sasaki, Tatsuo
    Oka, Yohichiro
    Itaka, Kohshi
    Araki, Tomoo
    Kawai, Kohei
    Hara, Takushi
    Yoshimura, Fumihiko
    Sugiyama, Noriyuki
    Satoh, Norio
    [J]. Sumitomo Electric Technical Review, 1987, (26): : 242 - 251
  • [2] Design of insulation dimension for ±500 kV DC gas insulated transmission line
    Jia, Zhijie
    Gan, Degang
    Li, Jing
    [J]. Dianwang Jishu/Power System Technology, 2011, 35 (08): : 192 - 196
  • [3] DEVELOPMENT OF COMPACT 500 KV 8,000 A GAS INSULATED TRANSMISSION LINE.
    Kobayashi, Takeshi
    Mori, Sadao
    Koshiishi, Masaaki
    Oka, Yoichiro
    Itaka, Koshi
    Araki, Tomoo
    Kawai, Kohei
    Hara, Takushi
    Sugiyama, Noriyuki
    [J]. Sumitomo Electric Technical Review, 1985, (24): : 80 - 89
  • [4] DEVELOPMENT OF COMPACT 500 kv 8000 A GAS INSULATED TRANSMISSION LINE - STUDY ON INSULATION DESIGN.
    Kobayashi, T.
    Mori, S.
    Koshiishi, M.
    Ninomiya, K.
    Matsuki, M.
    Yokoyama, H.
    Hara, T.
    [J]. IEEE transactions on power apparatus and systems, 1984, PAS-103 (11): : 3154 - 3164
  • [5] DEVELOPMENT AND APPLICATION OF 500 kV GAS INSULATED TRANSMISSION LINES.
    Araki, Tomoo
    [J]. 1600, (25):
  • [6] DEVELOPMENT OF COMPACT 500 KV 8000 A GAS INSULATED TRANSMISSION-LINE - STUDY ON INSULATION DESIGN
    KOBAYASHI, T
    MORI, S
    KOSHIISHI, M
    NINOMIYA, K
    MATSUKI, M
    YOKOYAMA, H
    HARA, T
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (11): : 3154 - 3164
  • [7] Research on lightning performance of insulated ground wire in 500kV extra high voltage transmission line
    Ma, Yutang
    Chen, Kui
    Ma, Yi
    Wang, Lei
    Cao, Xiaobin
    [J]. 2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 768 - 771
  • [8] The DC Melting Technology Research of the 500 kV Transmission Line
    Zhi, Li
    Hao, Bing
    Ran, Shuangwu
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 474 - 477
  • [9] Research and Application of UHVAC Gas-Insulated Transmission Line
    Li P.
    Yan X.
    Wang H.
    Zhang Q.
    Jin G.
    Gao Y.
    Mu S.
    [J]. 1600, Power System Technology Press (41): : 3161 - 3167
  • [10] 220 kV gas-insulated transmission line - Palexpo Geneva Switzerland
    Renaud, F
    [J]. 2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 2476 - 2479