Effects of Examiner Strength on Reliability of Hip-Strength Testing Using a Handheld Dynamometer

被引:1
|
作者
Krause, David A. [1 ]
Neuger, Mathew D. [1 ]
Lambert, Kimberly A. [1 ]
Johnson, Amanda E. [1 ]
DeVinny, Heather A. [1 ]
Hollman, John H. [1 ]
机构
[1] Mayo Clin, Program Phys Therapy, Rochester, MN 55905 USA
关键词
hip; muscle strength; physical examination; PATELLOFEMORAL PAIN SYNDROME; MUSCLE STRENGTH; EXTREMITY STRENGTH; BREAK TESTS; RUNNERS; FEMALES; WEAKNESS;
D O I
10.1123/JSR.2012-0070
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Hip-muscle impairments are associated with a variety of lower-extremity dysfunctions. Accurate assessment in the clinical setting can be challenging due to the strength of hip muscles relative to examiner strength. Objective: To examine the influence of examiner strength and technique on manual hip-strength testing using a handheld dynamometer. Design: Repeated measures. Setting: Research laboratory. Participants: 30 active adults (age 24 +/- 1.4 y). Interventions: Three examiners of different strength performed manual muscle tests (MMT) in 2 different positions for hip extension, abduction, and external rotation using a MicroFet handheld dynamometer. Examiner strength was quantified via a 1-repetition-maximum leg press and chest press with a Keiser A420 pneumatic resistance machine. Main Outcome Measures: Intrarater reliability (ICC3,1), interrater reliability (ICC2,1), and measured torque values. Results: Intrarater reliability for all measurements ranged from .82 to .97. Interrater reliability ranged from .81 to .98. Main effects for hip extension revealed a significant difference in torque values between examiners and between techniques. For the short-lever hip-abduction and seated hip-external-rotation tests, there was a significant difference between examiners. There was no significant difference in measured torque values between examiners with the long-lever hip-abduction or the prone hip-external-rotation tests. Conclusions: MMT of the hip may be performed with high reliability by examiners of different strength. To obtain valid MMT measurements of hip muscles, examiners must consider their own strength and testing techniques employed. The authors recommend a long-lever technique for hip abduction and a prone position for testing hip external rotation to minimize the influence of examiner strength. Both positions appear to provide mechanical advantages to the examiner compared with the alternative techniques. The authors are unable to recommend a preferred hip-extension-testing technique to minimize the influence of examiner strength.
引用
收藏
页码:56 / 64
页数:9
相关论文
共 50 条
  • [1] INFLUENCE OF TESTING POSITION ON THE RELIABILITY OF HIP EXTENSOR STRENGTH MEASURED BY A HANDHELD DYNAMOMETER
    Lue, Yi-Jing
    Hsieh, Ching-Lin
    Liu, Mei-Fang
    Hsiao, Shih-Fen
    Chen, Shu-Mei
    Lin, Jau-Hong
    Lu, Yen-Mou
    [J]. KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2009, 25 (03): : 126 - 132
  • [2] Testing the Hip Abductor Muscle Strength of Older Persons Using a Handheld Dynamometer
    Awwad, Daniel H.
    Buckley, Jonathan D.
    Thomson, Rebecca L.
    O'Connor, Matthew
    Carbone, Tania A.
    Chehade, Mellick J.
    [J]. GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2017, 8 (03) : 166 - 172
  • [3] THE RELATIVE AND ABSOLUTE RELIABILITY OF LEG MUSCLE STRENGTH TESTING BY A HANDHELD DYNAMOMETER
    Lu, Yen-Mou
    Lin, Jau-Hong
    Hsiao, Shih-Fen
    Liu, Mei-Fang
    Chen, Shu-Mei
    Lue, Yi-Jing
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (04) : 1065 - 1071
  • [4] Measuring seated hip extensor strength using a handheld dynamometer: an examination of the reliability and validity of the protocol
    Seko, Toshiaki
    Kumamoto, Tsuneo
    Miura, Sayo
    Kobayashi, Takumi
    Takahashi, Yui
    Kaneko, Ryousuke
    Morino, Akira
    Ito, Toshikazu
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (07) : 2179 - 2182
  • [5] Reliability and Validity of Seated Hip Extensor Strength Measurement by Handheld Dynamometer in Older Adults
    Seko, Toshiaki
    Mori, Mitsuru
    Ohnishi, Hirofumi
    Himuro, Nobuaki
    Takahashi, Yui
    Kumamoto, Tsuneo
    Ito, Toshikazu
    [J]. JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2019, 42 (04) : E39 - E44
  • [6] A Comparison of Various Cervical Muscle Strength Testing Methods Using a Handheld Dynamometer
    Krause, David A.
    Hansen, Kelsey A.
    Hastreiter, Matthew J.
    Kuhn, Taylor N.
    Peichel, Molly L.
    Hollman, John H.
    [J]. SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2019, 11 (01): : 59 - 63
  • [7] Validity of the Handheld Dynamometer Compared with an Isokinetic Dynamometer in Measuring Peak Hip Extension Strength
    Keep, Heather
    Luu, Levana
    Berson, Ayli
    Garland, S. Jayne
    [J]. PHYSIOTHERAPY CANADA, 2016, 68 (01) : 15 - 22
  • [8] The intra- and interrater reliability of hip muscle strength assessments using a handheld versus a portable dynamometer anchoring station
    Scott, DA
    Bond, EQ
    Sisto, SA
    Nadler, SF
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (04): : 598 - 603
  • [9] Assessment of isometric strength of the shoulder rotators in swimmers using a handheld dynamometer: a reliability study
    Conceicao, Ana
    Parraca, Jose
    Marinho, Daniel
    Costa, Mario
    Louro, Hugo
    Silva, Antonio
    Batalha, Nuno
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2018, 20 (04) : 113 - 119
  • [10] Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity
    Johansson, Fredrik R.
    Skillgate, Eva
    Lapauw, Mattis L.
    Clijmans, Dorien
    Deneulin, Valentijn P.
    Palmans, Tanneke
    Cools, Ann M.
    [J]. JOURNAL OF ATHLETIC TRAINING, 2015, 50 (07) : 719 - 725