Numerical analysis of the effect of solid rod on the flow field and separation performance of thick-walled overflow pipe hydrocyclone

被引:34
|
作者
Li, Feng [1 ]
Liu, Peikun [1 ]
Yang, Xinghua [1 ]
Zhang, Yuekan [1 ]
Jiang, Lanyue [1 ]
Wang, Hui [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Mech & Elect Engn, Qingdao 266590, Peoples R China
关键词
Thick-walled overflow pipe; Solid rod; Air core; Cutting size; Separation accuracy; AIR-CORE SIZE; OPERATING PARAMETERS; FLUID-FLOW; SIMULATION; CYCLONE; DESIGN; MODELS;
D O I
10.1016/j.powtec.2021.04.077
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Hydrocyclone is one of the common equipment for solid-liquid separation. Although the hydrocyclone has a simple structure, it has many shortcomings. Among them, short-circuit flow and air core are two important factors that affect the separation performance. Many researchers have tried to weaken the short-circuit flow by changing the structure of the overflow pipe and the trajectory of the particles. This is certainly a feasible method to reduce the short-circuit flow. Is it possible to reduce the short-circuit flow by increasing the movement distance of the short-circuit flow and re-entering the short-circuit flow into the separation area without changing the structure of the overflow pipe? The answer is yes. In this paper, a thick-walled overflow pipe structure was proposed to increase the distance of the short-circuit flow into the bottom end of the overflow pipe.In the proposed structure, the particles in the short-circuit flow can be brought back into the separation area through the circulating flow at the bottom of the overflow pipe. During the working process, the hydrocyclone produces a unique phenomenon air core. Although the air core does not participate in particle separation, it consumes energy and compresses the separation area. In order to further improve the separation performance of the thick-walled overflow pipe hydrocyclone, a central solid rod was traversed throughout the hydrocyclone to weaken the air core. In addition, FLUENT was used to numerically analyze the thick-walled overflow pipe hydrocyclone with an inserted solid rod in the center. Moreover, we investigated the effect of the solid rod with different diameters on the separation performance of the hydrocyclone. The numerical simulation was verified by comparing the simulation data with the classic data. The results showed that the pressure distribution of the thick-walled overflow pipe hydrocyclonewas more reasonable. The inserted solid rod significantly improved, the pressure distribution. Compared with the conventional hydrocyclone, the short-circuit flow rate of the thick-walled overflow pipe hydrocyclone was reduced by 8.09%. The cutting size of the particles can be adjusted by changing the diameter of the solid rod. When the diameter of the solid rod was 5-6 mm, the cutting size was in the range of 11.6-12.2 mu m. When the diameter of the solid rod exceeded 6 mm, the cutting size gradually increased. The appropriate diameter of the solid rod can improve the separation accuracy of thick-walled overflow pipe hydrocyclone, resulting in thinner and higher quality products. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 273
页数:13
相关论文
共 20 条
  • [1] Effect of the Axially Inserted Solid Rod on the Flow Field Characteristics and Separation Performance of a Hydrocyclone
    Su, Tenglong
    Zhang, Yifei
    ACS OMEGA, 2022, 7 (28): : 24208 - 24218
  • [2] Numerical analysis on the effect of the length of arc-shaped vortex finder on the hydrocyclone's flow field and separation performance
    Li, Feng
    Liu, Peikun
    Yang, Xinghua
    Zhang, Yuekan
    Li, Xiaoyu
    Jiang, Lanyue
    Wang, Hui
    Fu, Wenxiu
    MINERALS ENGINEERING, 2021, 172
  • [3] AN ANALYSIS OF THE FLOW OF BLOOD THROUGH THICK-WALLED VESSELS, CONSIDERING THE EFFECT OF TETHERING
    MISRA, JC
    CHOUDHURY, KR
    RHEOLOGICA ACTA, 1984, 23 (05) : 548 - 555
  • [4] Numerical simulation on the effects of different inlet pipe structures on the flow field and seperation performance in a hydrocyclone
    Li, Feng
    Liu, Peikun
    Yang, Xinghua
    Zhang, Yuekan
    POWDER TECHNOLOGY, 2020, 373 : 254 - 266
  • [5] Numerical Simulation of Flow Field Characteristics and Separation Performance Test of Multi-Product Hydrocyclone
    Zhang, Yuekan
    Liu, Peikun
    Jiang, Lanyue
    Yang, Xinghua
    Yang, Junru
    MINERALS, 2019, 9 (05):
  • [6] Effect of Overflow Pipe on the Internal Flow Fields and Separation Performance of W-Shaped Hydrocyclones
    Jiang, Lanyue
    Liu, Peikun
    Yang, Xinghua
    Zhang, Yuekan
    Li, Xiaoyu
    Zhang, Yulong
    Wang, Hui
    MINERALS, 2020, 10 (04)
  • [7] Numerical analysis of non-Newtonian rheology effect on hydrocyclone flow field
    Lin Yang
    Jialin Tian
    Zhi Yang
    You Li
    Chuanhong Fu
    Yonghao Zhu
    Xiaolin Pang
    Petroleum, 2015, 1 (01) : 68 - 74
  • [8] Prediction of Liquid Viscosity Effect on Flow Field and Performance in a Solid-Liquid Hydrocyclone
    Feng, Ding
    Huang, Si
    Luo, Li
    Ma, Weiguo
    EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 401 - +
  • [9] Numerical Analysis of the Effect of the Vortex Finder on the Hydrocyclone's Split Water Ratio and Separation Performance
    Hashe, Vuyo T.
    Kunene, Thokozani J.
    MATHEMATICAL AND COMPUTATIONAL APPLICATIONS, 2023, 28 (02)
  • [10] Effect of column segment diameter ratio on flow field and separation performance of the composite column-cone hydrocyclone
    Liu, Peikun
    Xu, Xiangxi
    Yang, Xinghua
    Li, Anjun
    Chen, Bo
    Liu, Gang
    Gao, Yunzhu
    PHYSICOCHEMICAL PROBLEMS OF MINERAL PROCESSING, 2025, 61 (01):