Precision tunable infrared source at 10 μm:: Co2-laser/microwave-sideband system with an Evenson Co2 laser and a Cheo waveguide modulator

被引:7
|
作者
Sun, ZD
Lees, RM
Xu, LH [1 ]
Tretyakov, MY
Yakovlev, I
机构
[1] Univ New Brunswick, Canadian Inst Photon Innovat, St John, NB E2L 4L5, Canada
[2] Univ New Brunswick, Dept Phys Sci, St John, NB E2L 4L5, Canada
关键词
CO2; laser; microwave sidebands; Lamb dip; tunable infrared; high-resolution spectroscopy;
D O I
10.1023/A:1020715616270
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A CO2-laser/microwave-sideband tunable infrared source system has been newly built at the University of New Brunswick (UNB) in Canada. The system employs a high-resolution CO2 laser of Evenson design that lases on a wide range of lines including hot and sequence band lines as well as high-J lines of the regular 9.6 and 10.6 mum bands. The frequency of the CO2 laser is stabilized to the Lamb dip in the 4.3 mum fluorescence signal in an external CO2 cell. Microwave (MAT) sidebands are generated in a Cheo-type infrared waveguide modulator driven by a synthesized sweeper and a traveling wave tube (TWT) amplifier. The MW sidebands appear on either side of the CO2 laser line, and are individually separated from the carrier by a tunable Fabry-Perot etalon. The sidebands currently have a typical power of about 1.4 mW and a continuous frequency tuning range of 22 GHz (from +/-7 to +/-18 GHz) when 5 W laser power and 15 W microwave power are delivered to the modulator. Details are given on the source construction and measured performance characteristics. Features of the source and its planned applications are discussed.
引用
收藏
页码:1557 / 1574
页数:18
相关论文
共 50 条
  • [1] Precision Tunable Infrared Source at 10 μM: CO2-Laser/Microwave-Sideband System with an Evenson CO2 Laser and a Cheo Waveguide Modulator
    Zhen-Dong Sun
    R. M. Lees
    Li-Hong Xu
    M. Yu. Tretyakov
    Ivan Yakovlev
    International Journal of Infrared and Millimeter Waves, 2002, 23 : 1557 - 1574
  • [2] CO2-laser/microwave-sideband tunable IR source for molecular spectroscopy with environmental and biomolecular applications
    Sun, ZD
    Lees, RM
    Xu, LH
    Tretyakov, MY
    Yakovlev, I
    TWENTY SEVENTH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES, CONFERENCE DIGEST, 2002, : 133 - 134
  • [3] A TUNABLE CO2-LASER SIDEBAND SPECTROMETER
    MAGERL, G
    SCHUPITA, W
    BONEK, E
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1982, 18 (08) : 1214 - 1220
  • [4] GIGAHERTZ TUNABLE WAVEGUIDE CO2-LASER
    ABRAMS, RL
    APPLIED PHYSICS LETTERS, 1974, 25 (05) : 304 - 306
  • [5] Saturation-dip measurements in the 2ν2 overtone band of OCS with a CO2-laser/microwave-sideband spectrometer
    Z.-D. Sun
    Q. Liu
    R.M. Lees
    L.-H. Xu
    M.Y. Tretyakov
    V.V. Dorovskikh
    Applied Physics B, 2004, 78 : 791 - 795
  • [6] Saturation-dip measurements in the 2ν2 overtone band of OCS with a CO2-laser/microwave-sideband spectrometer
    Sun, ZD
    Liu, Q
    Lees, RM
    Xu, LH
    Tretyakov, MY
    Dorovskikh, VV
    APPLIED PHYSICS B-LASERS AND OPTICS, 2004, 78 (06): : 791 - 795
  • [7] 2.75-GHZ TUNABLE CO2-LASER INFRARED SOURCE
    MAGERL, G
    BONEK, E
    JOURNAL OF APPLIED PHYSICS, 1976, 47 (11) : 4901 - 4903
  • [8] Precision Lamb-dip infrared spectra of the C-N stretching band of CH3NH2 with a CO2-laser/microwave-sideband spectrometer
    Sun, Zhen-Dong
    Lees, Ronald M.
    Xu, Li-Hong
    JOURNAL OF CHEMICAL PHYSICS, 2010, 132 (19):
  • [9] SubDoppler spectroscopy with a tunable sideband CO2 laser
    Rusinek, E
    Khelkhal, M
    Fichoux, H
    Legrand, J
    Herlemont, F
    12TH SYMPOSIUM AND SCHOOL ON HIGH-RESOLUTION MOLECULAR SPECTROSCOPY, 1997, 3090 : 42 - 50
  • [10] WAVEGUIDE LASER FOR FAR INFRARED (FIR) PUMPED BY A CO2-LASER
    HODGES, DT
    HARTWICK, TS
    APPLIED PHYSICS LETTERS, 1973, 23 (05) : 252 - 253