摘要
With the increasing integration into power grids, wind power plants play an important role in the power system. Many requirements for the wind power plants have been proposed in the grid codes. According to these grid codes, wind power plants should have the ability to perform voltage control and reactive power compensation at the point of common coupling (PCC). Besides the shunt flexible alternating current transmission system (FACTS) devices such as the static var compensator (SVC) and the static synchronous compensator (STATCOM), the wind turbine itself can also provide a certain amount of reactive power compensation, depending on the wind speed and the active power control strategy. This paper analyzes the reactive power capability of Doubly Fed Induction Generator (DFIG) based wind turbine, considering the rated stator current limit, the rated rotor current limit, the rated rotor voltage limit, and the reactive power capability of the grid side convertor (GSC). The boundaries of reactive power capability of DFIG based wind turbine are derived. The result was obtained using the software MATLAB.
引用
收藏
页码:5312 / 5317
页数:6
相关论文
共 50 条
  • [1] Reactive power capability of a wind turbine with doubly fed induction generator
    Lund, Torsten
    Sorensen, Poul
    Eek, Jarle
    [J]. WIND ENERGY, 2007, 10 (04) : 379 - 394
  • [2] Mining and Utilization of Reactive Power Capability of Doubly fed Induction Generator Systems for Wind Turbines
    Huang Ya-feng
    Yan Gan-gui
    Chao Chu-yan
    Mu Gang
    Zhang Zhen-qing
    Xu Fei
    Zhang Cheng-xin
    [J]. 2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 1579 - +
  • [3] A comparative study for reactive power capability of doubly fed induction generator and synchronous generator
    Kumar, Sanjeev
    Singh, Omveer
    Aggarwal, S. K.
    [J]. 2016 2ND IEEE INTERNATIONAL CONFERENCE ON CONTROL, COMPUTING, COMMUNICATION AND MATERIALS (ICCCCM), 2016,
  • [4] Intelligent Approach for Active and Reactive Power Control in Doubly Fed Induction Generator Wind Turbine System
    Pandey, Kamlesh
    Bharath, KurukuruVarahaSatya
    [J]. 2016 7TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2016,
  • [5] A direct torque and reactive power control approach for doubly fed induction generator in wind turbine applications
    Liu, Qian
    Hameyer, Kay
    [J]. 2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2012, : 804 - 809
  • [6] Analysis, simulation and testing of the ZVRT capability of a wind turbine with a doubly fed induction generator
    Cai, Enyu
    Liao, Xiaozhong
    Dong, Lei
    Li, Yongzhan
    Jiao, Chong
    [J]. IET RENEWABLE POWER GENERATION, 2020, 14 (14) : 2738 - 2749
  • [7] Wind turbine with doubly fed induction generator operating at limited power point
    Lazarov, V. D.
    Stoyanov, L. S.
    Zarkov, Z. J.
    Notton, G.
    [J]. 2012 15TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE/PEMC), 2012,
  • [8] Power Smoothing of Doubly Fed Induction Generator for Wind Turbine Using Ultracapacitors
    Luu, T.
    Nasiri, A.
    [J]. IECON 2010 - 36TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2010,
  • [9] Reactive Power Capability of Wind Turbines Based on Doubly Fed Induction Generators
    Engelhardt, Stephan
    Erlich, Istvan
    Feltes, Christian
    Kretschmann, Joerg
    Shewarega, Fekadu
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 364 - 372
  • [10] Reduced Cost of Reactive Power in Doubly Fed Induction Generator Wind Turbine System With Optimized Grid Filter
    Zhou, Dao
    Blaabjerg, Frede
    Franke, Toke
    Tonnes, Michael
    Lau, Mogens
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (10) : 5581 - 5590