Combination Weight COD Concentration Prediction Model Based on BiPLS and SiPLS

被引:7
|
作者
Chen Ying [1 ]
Di Yuan-jian [1 ]
Tang Xin-liang [2 ]
Cui Xing-ning [1 ]
Gao Xin-bei [1 ]
Cao Jing-gang [1 ]
Li Shao-hua [3 ]
机构
[1] Yanshan Univ, Sch Elect Engn, Hebei Prov Key Lab Test Measurement Technol & Ins, Qinhuangdao 066004, Hebei, Peoples R China
[2] Hebei Univ Sci & Technol, Sch Informat Sci & Engn, Shijiazhuang 050018, Hebei, Peoples R China
[3] Hebei Sailhero Environm Protect Hitech Co Ltd, Shijiazhuang 050000, Hebei, Peoples R China
关键词
UV spectrum; Screen and combination of intervals; Interval weight; COD concentration prediction model; CHEMICAL OXYGEN-DEMAND; CALIBRATION; TSS;
D O I
10.3964/j.issn.1000-0593(2019)07-2176-06
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The excessively high concentration of organic matter in water poses a great harm, which not only causes serious environmental pollution, but also harms human health. The traditional chemical method for detecting COD(Chemical oxygen denmand, COD) in water usually takes a long time, which is not conducive to rapid quantitative detection of COD in water. In order to solve these problems, a rapid and quantitative detection of COD using a combination of UV spectroscopy and combined weight models is proposed in this paper, the prediction model is based on the backward interval partial least squares (BiPLS) and synergy interval partial least squares (SiPLS) algorithm for screening the characteristic Intervals of UV spectra, and then based on the weights of the characteristic Intervals, a combination weight concentration prediction model is established. In this paper, 45 samples of COD standard solution are experimented ; The first derivative and S-G screening of COD UV spect rum date are preprocessed to eliminate baseline drift and environmental noise ; The SPXY algorithm is used to divide the experimental data sets into calibration sets and prediction sets. Then, the wavelength of the whole spectral range is screened based on the BiPLS algorithm. In the process of BiPLS screening, the selection of the number of target interval division will have a great influence on the model, so the number of Interval divisions is optimized, subintervals are divided into 15 to 25, and PLS modeling is performed under different interval numbers. The optimal subinterval number is selected by cross-validating root mean square error (RMSECV). When the number of intervals is 18, the effect of the model is the best. 6 characteristic wavelengths are selected from 18 wavelengths. The selected Intervals are 2, 1, 3, 11, 7, 6, and the corresponding wavelengths are 234 similar to 240, 262 similar to 268, 269 similar to 275, 290 similar to 296, 297 similar to 303, 304 similar to 310 nm, respectively. These 6 characteristic wavelength ranges cover a large amount of spectral information and contribute greatly to the final prediction model. Then, these 6 regions are further screened and combined through the SiPLS algorithm, PLS models with different characteristic intervals are constructed using different combinations under the same combination number, the optimal results of an interval combination number are screened out, and the error and correlation of the prediction models under different combinations are compared, the 6 interval are combined into 3 characteristic wavelength intervals, which are 234 similar to 240, 262 similar to 275 and 290 similar to 310 nm respectively. The optimal factor of the optimal PLS model for these three characteristic intervals is 4, 4 and 3, respectively. The characteristic interval combination method of the traditional SiPLS is improved, and the three characteristic intervals are linearly combined based on the weight value instead of the previous direct combination of characteristic intervals. The weights of these three characteristic intervals are calculated by the weight formula as 0. 509, 0. 318 and 0. 173 respectively. Finally, a linear combination weight COD concentration prediction model is established. In order to verify the accuracy of the combined weight prediction model, a PLS prediction model over the full wavelength range, a PLS prediction model with a single characteristic wavelength interval, and a PLS model directly combining characteristic wavelength intervals are established, and the square of the correlation coefficient of the evaluation parameter (R-2) , the root mean square error of the predicted value and the true concentration value (RMSEC) as well as the Predicted recovery (T) are used to evaluate the model. Compared with other predictive models, the verification results show that the square of the correlation coefficient of the combined weight model reaches 0. 999 7, which is obviously higher than the 0. 968 0 of the direct combined characteristic interval model, the prediction root mean square error is 0. 532, which is more than the prediction of the direct combination characteristic intervals. The model error is reduced by 29. 3% , the predicted recovery rate is 96. 4% similar to 103. 1% , which significantly improves the prediction accuracy. The method is simple and feasible without generating twice pollution, which can provide some technical support for on-line monitoring of COD concentration in water.
引用
收藏
页码:2176 / 2181
页数:6
相关论文
共 13 条
  • [1] Agustsson J, 2014, ENVIRON SCI-PROC IMP, V16, P1897, DOI [10.1039/c3em00707c, 10.1039/C3EM00707C]
  • [2] Study on Fano resonance regulating mechanism of Si contained metal-dielectric-metal waveguide coupled rectangular cavity
    Chen, Ying
    Luo, Pei
    Zhao, Zhi-yong
    He, Lei
    Cui, Xing-ning
    [J]. PHYSICS LETTERS A, 2017, 381 (40) : 3472 - 3476
  • [3] Application of surrogate parameters in characteristic UV-vis absorption bands for rapid analysis of water contaminants
    Hu, Yingtian
    Wang, Xiaoping
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 : 718 - 726
  • [4] Novel method of turbidity compensation for chemical oxygen demand measurements by using UV-vis spectrometry
    Hu, Yingtian
    Wen, Yizhang
    Wang, Xiaoping
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 227 : 393 - 398
  • [5] Leardi R, 2010, J CHEMOMETR, V18, P486
  • [6] Calibration of UV/Vis spectrophotometers: A review and comparison of different methods to estimate TSS and total and dissolved COD concentrations in sewers, WWTPs and rivers
    Lepot, Mathieu
    Torres, Andres
    Hofer, Thomas
    Caradot, Nicolas
    Gruber, Guenter
    Aubin, Jean-Baptiste
    Bertrand-Krajewski, Jean-Luc
    [J]. WATER RESEARCH, 2016, 101 : 519 - 534
  • [7] Multivariate Calibration of a UV-Vis Spectrophotometer Used for Online Measurements of Chemical Oxygen Demand in Dyeing Wastewater
    Mai Wei
    Zhao Xiao-ming
    Zhang Jian-fei
    Xu Zhi-wei
    Li Zheng
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (07) : 2105 - 2109
  • [8] In situ UV-Vis spectroscopy to estimate COD and TSS in wastewater drainage systems
    Salgado Brito, R.
    Pinheiro, H. M.
    Ferreira, F.
    Saldanha Matos, J.
    Lourenco, N. D.
    [J]. URBAN WATER JOURNAL, 2014, 11 (04) : 261 - 273
  • [9] Development of Ultra-violet Light-emitting Diode Based Portable Fluorometer and Its Application to Estimations of COD
    Suzuki, Yasutada
    Kikuta, Yoshihiro
    Yamada, Kazuhiro
    Kitade, Kazuhisa
    Maruta, Toshihisa
    Ichida, Junichi
    Kawakubo, Susumu
    [J]. BUNSEKI KAGAKU, 2014, 63 (11) : 895 - 902
  • [10] Tang Bin Tang Bin, 2015, China Environmental Science, V35, P478