Voltage Ride-Through Capability Verification of Wind Turbines With Fully-Rated Converters Using Reachability Analysis

被引:24
|
作者
Pico, Hugo N. Villegas [1 ]
Aliprantis, Dionysios C. [1 ]
机构
[1] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
关键词
Converters; permanent magnet machines; power system faults; reachability analysis; wind power generation; COMPUTATIONAL TECHNIQUES; HYBRID;
D O I
10.1109/TEC.2013.2295168
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind turbines are required to meet grid interconnection codes for voltage ride-through, which mandate that they should not disconnect during a specified range of grid disturbances. One of the tasks of a turbine's design verification process is to ensure that it will be able to withstand any such event. This paper sets forth a powerful computational technique for design verification of Type-4 permanent-magnet synchronous generator-based turbines with fully-rated grid-side converters. The proposed method can provide assurance as to whether the currents and voltages will remain within acceptable bounds. To this end, reachability theory is employed to find sets that enclose all possible trajectories for the system states caused by a given set of unknown-but-bounded disturbances. The computation of the reachable sets is carried out by using on-the-fly linearization of the nonlinear system dynamics, zonotopes, and interval analysis.
引用
收藏
页码:392 / 405
页数:14
相关论文
共 50 条
  • [1] Voltage ride-through capability verification of wind turbines with fully-rated converters using reachability analysis
    Pico, Hugo Villegas
    Aliprantis, Dionysios
    [J]. 2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [2] Voltage Ride-Through Capability Verification of DFIG-Based Wind Turbines Using Reachability Analysis
    Pico, Hugo N. Villegas
    Aliprantis, Dionysios C.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) : 1387 - 1398
  • [3] High-voltage ride-through strategy for wind turbine with fully-rated converter based on current operating range
    Liu, Peilin
    Zhu, Guofang
    Ding, Lei
    Gao, Xuesong
    Jia, Chunjiang
    Ng, Chong
    Terzija, V.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [4] Feasibility Analysis on High Voltage Ride-Through of Wind Turbines
    Song, Fei
    Wang, Tong
    Tang, Kan
    Zhu, Dan
    [J]. ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING, PTS 1-3, 2013, 278-280 : 134 - 138
  • [5] Fault ride-through capability of DFIG wind turbines
    Hansen, Anca D.
    Michalke, Gabriele
    [J]. RENEWABLE ENERGY, 2007, 32 (09) : 1594 - 1610
  • [6] Blackstart Capability and Survivability of Wind Turbines With Fully Rated Converters
    Pico, Hugo N. Villegas
    Gevorgian, Vahan
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (04) : 2482 - 2497
  • [7] Blackstart Capability and Survivability of Wind Turbines with Fully Rated Converters
    Villegas, Hugo
    Gevorgian, Vahan
    [J]. 2023 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM, 2023,
  • [8] Analysis of low voltage ride-through capability for Variable speed wind turbines using experimental and measured data
    Lv Xiangyu
    Gao Bo
    Caiguowei
    Li Dexin
    [J]. RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 1865 - 1870
  • [9] Low and high voltage ride-through of DFIG wind turbines using hybrid current controlled converters
    Mohseni, Mansour
    Masoum, Mohammad A. S.
    Islam, Syed M.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) : 1456 - 1465
  • [10] Fault ride-through capability test unit for wind turbines
    Ausin, Juan Carlos
    Gevers, Daniel Navarro
    Andresen, Bjorn
    [J]. WIND ENERGY, 2008, 11 (01) : 3 - 12