摘要
In this study, a series of shaking table tests of a ten storey concrete suspended structure equipped with viscous dampers were carried out to evaluate the dynamic responses and vibration damping performance of suspended structures. The effects of link types between the primary structure and suspended floors and different seismic excitations on the response of suspended structure models was verified. The responses include the damping ratio, the frequency, maximum relative displacements, accelerations and maximum strains of the suspended structures. Test results showed that the damping ratio and the frequency of suspended structures installed with dampers (called damping suspended structure) are adjusted compared with a conventional suspended structure with rigid-bar links (conventional suspended structure). Maximum relative displacements of the primary structure of the damping suspended structure were distinctly smaller than those of the conventional suspended structure. However, the maximum relative displacement between the primary structure and the suspended floors of the damping suspended structure was significantly larger than that of the conventional structure, indicating that the swing of the suspended floor can help dissipate seismic energy. The peak acceleration and acceleration amplification factors of the damping suspended structure were less than the conventional suspended structure. Moreover, the peak acceleration response of the damping suspended structure was slightly behind the conventional suspended structure. The damping suspended structure certainly had a considerable and stable reduction for strain response, and the maximum strain response was decreased by 42.3%-72.7% for the damping suspended structure compared with the conventional suspended structure.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Shaking table tests for structures with viscous dampers considering SSI effect
    Zhao, Xuefei
    Wang, Shuguang
    Wang, Hai
    Du, Dongsheng
    Liu, Weiqing
    Zhendong yu Chongji/Journal of Vibration and Shock, 2017, 36 (13): : 146 - 154
  • [2] Shaking Table Tests of a Structure Equipped with Superelastic Dampers
    Branco, M.
    Guerreiro, L.
    Campos Costa, A.
    Candeias, P.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (05) : 674 - 695
  • [3] Shaking table tests and dynamic reliability analysis for aseismic structures with viscous dampers
    Mei Z.
    Hou W.
    Guo Z.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2018, 37 (03): : 136 - 142
  • [4] Shaking table experiment of vibration-controlling suspended-floor structure equipped with viscous dampers
    Wang, Chunlin
    Lü, Zhitao
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2012, 33 (10): : 32 - 38
  • [5] Shaking table tests for a continuous girder bridge's aseismic control with viscous dampers
    Li Y.
    Wang W.
    Yan W.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2018, 37 (23): : 91 - 97
  • [6] Shaking table tests for base-suspended pendulum isolation structures
    Lu, Liang
    Hu, Yufei
    Zhang, Huihui
    Luo, Jianwen
    He, Yanqing
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (05): : 71 - 79
  • [7] Shaking table tests and numerical studies on the effect of viscous dampers on an isolated RC building by friction pendulum bearings
    Zhou, Ying
    Chen, Peng
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2017, 100 : 330 - 344
  • [8] Shaking table test and numerical analysis of RC frames with viscous wall dampers
    Lu, Xilin
    Zhou, Ying
    Yan, Feng
    JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (01) : 64 - 76
  • [9] Shaking table tests on seismic response of discontinuous suspended ceilings
    Zhou, Tiegang
    Wang, Xin
    Liu, Wenhui
    Zhang, Zaiyu
    Ma, Ben
    Tan, Wei
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [10] Shaking table tests on seismic response of discontinuous suspended ceilings
    Zhou, Tiegang
    Wang, Xin
    Liu, Wenhui
    Zhang, Zaiyu
    Ma, Ben
    Tan, Wei
    Journal of Building Engineering, 2021, 43