Gunshot residue on dark materials: a comparison between infrared photography and the use of an alternative light source

被引:6
|
作者
Barrera, V [1 ]
Fliss, B. [1 ]
Panzer, S. [2 ]
Bolliger, S. A. [1 ]
机构
[1] Univ Zurich, Inst Forens Med, Wintcrthurcrstr 190-52, CH-8057 Zurich, Switzerland
[2] Julius Maximilian Univ Wurzburg, Dept Biotechnol & Biophys, D-97074 Wurzburg, Germany
关键词
Shooting distance; Infrared photography; Crime scene investigation; Gunshot residue GSR; Forensic light source; Alternative light source; PATTERNS; FABRICS;
D O I
10.1007/s00414-018-1965-7
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The pattern of gunshot residue (GSR) includes important information about muzzle-target distance since a larger GSR distribution diameter indicates a larger shooting distance. GSR may not be visible to the naked eye when, for example, it is located on dark textiles. In such cases, further procedures need to be performed in order to visualize the pattern of GSR. Besides chemical procedures, an alternative light source or infrared photography can be utilized for non-destructive GSR visualization. In the work presented, these two techniques are compared based on shooting experiments using 26 different dark textiles. Within the range of the alternative light source, the use of a 440-nm light in combination with an orange-colored filter led to the best visualization of GSR in the form of fluorescent particles. Infrared photography, on the other hand, visualized GSR as dark particles, whereasideallythe dark textile reflected the infrared light and appeared bright. The comparison of both techniques revealed that the GSR distribution visualized by infrared photography was not identical to the GSR distribution visualized with 440-nm illumination in combination with an orange-colored filter. We concluded that infrared photography visualizes the inner powder soot zone, whereas illumination at 440nm leads to fluorescence of the outer powder soot zone, which can be visualized using an orange-colored filter. Knowledge of this difference in visualization of the two powder soot zones is important for forensic practitioners assessing firing distances. In the literature, however, this difference is not noted as clearly.
引用
收藏
页码:1115 / 1120
页数:6
相关论文
共 50 条
  • [1] Gunshot residue on dark materials: a comparison between infrared photography and the use of an alternative light source
    V. Barrera
    B. Fliss
    S. Panzer
    S. A. Bolliger
    International Journal of Legal Medicine, 2019, 133 : 1115 - 1120
  • [5] Comparison of near infrared light photography and middle infrared light photography for deciphering obliterated writings
    Sugawara, S
    JOURNAL OF FORENSIC SCIENCES, 2004, 49 (06) : 1349 - 1352
  • [6] Searching for biological traces on different materials using a forensic light source and infrared photography
    Sterzik, V.
    Panzer, S.
    Apfelbacher, M.
    Bohnert, M.
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2016, 130 (03) : 599 - 605
  • [7] Searching for biological traces on different materials using a forensic light source and infrared photography
    V. Sterzik
    S. Panzer
    M. Apfelbacher
    M. Bohnert
    International Journal of Legal Medicine, 2016, 130 : 599 - 605
  • [8] Surveys of organic gunshot residue prevalence: Comparison between civilian and police populations
    Manganelli, Manuela
    Weyermann, Celine
    Gassner, Anne-Laure
    FORENSIC SCIENCE INTERNATIONAL, 2019, 298 : 48 - 57
  • [9] Comparison of visible-light and infrared photography for visualizing hematomas postmortem
    Bottoni, Joel
    Rost, Thomas
    Wittig, Holger
    Bauer, Melanie
    Scheurer, Eva
    Lenz, Claudia
    FORENSIC SCIENCE INTERNATIONAL, 2025, 366
  • [10] Bioconversion of soybean residue for use as alternative nutrient source for ethanol fermentation
    Salakkam, Apilak
    Kingpho, Yulada
    Najunhom, Siriporn
    Aiamsonthi, Khwanchanok
    Kaewlao, Sukanya
    Reungsang, Alissara
    BIOCHEMICAL ENGINEERING JOURNAL, 2017, 125 : 65 - 72