Determination of microfibril angle distribution by X-ray diffraction

被引:28
|
作者
Saren, Matti-P.
Serimaa, Ritva
机构
[1] Univ Oulu, Measurement & Sensor Lab, Kajaani 87400, Finland
[2] Univ Helsinki, Div Xray Phys, Dept Phys Sci, FIN-00014 Helsinki, Finland
关键词
D O I
10.1007/s00226-005-0052-7
中图分类号
S7 [林业];
学科分类号
0829 ; 0907 ;
摘要
X-ray diffraction is a well-established method for the determination of the mean microfibril angle (MFA). When the sample is a slice of wood variations in the fibre orientation, the shape of the cells, and the measurement geometry affect the intensity curve. A general form for diffraction conditions in terms of angles describing the fibre orientation and the shape of the cell was derived. Intensity curves were calculated by using Monte Carlo method and compared with experimental ones. Both peak fitting and variance methods were used for determining the mean MFA from the intensity curves. Norway spruce was used as an example. Results indicate that deviations in the fibre orientation, the spiral grain, do not affect the mean MFA considerably when using the symmetrical transmission geometry. When using the perpendicular transmission geometry large deviations in spiral grain or tips tend to increase the MFA determined with the variance method and decrease the MFA determined with the fitting method. The shape of the cell should be considered when using the reflection 200 and the fitting method. The variance method is insensitive to the shape of the cell.
引用
收藏
页码:445 / 460
页数:16
相关论文
共 50 条
  • [1] Determination of microfibril angle distribution by X-ray diffraction
    Matti-P. Sarén
    Ritva Serimaa
    Wood Science and Technology, 2006, 40 : 445 - 460
  • [3] Microfibril angle variation by scanning X-ray diffractometry
    Evans, R
    Hughes, N
    Menz, D
    APPITA JOURNAL, 1999, 52 (05): : 363 - 367
  • [4] Microfibril angle variation by scanning x-ray diffractometry
    Evans, R
    Hughes, M
    Menz, D
    52ND APPITA ANNUAL GENERAL CONFERENCE, 1998 PROCEEDINGS, VOLS 1 AND 2, 1998, : 27 - 32
  • [6] Investigation of Microfibril Angle of Flax Fibers Using X-Ray Diffraction and Scanning Electron Microscopy
    Wang, Chunhong
    Wang, Ni
    Liu, Shuhan
    Choo-Simth, Lin-P'ing
    Zhang, Hongxia
    Zhi, Zhongxiang
    JOURNAL OF NATURAL FIBERS, 2020, 17 (07) : 1001 - 1010
  • [7] Application of X-ray diffraction to assess the microfibril angle of green and dry Eucalyptus grandis wood
    Marques de Souza, Naiara Conceicao
    Lima, Jose Tarcisio
    Dias Soares, Bruno Charles
    TREES-STRUCTURE AND FUNCTION, 2022, 36 (01): : 191 - 197
  • [8] Application of X-ray diffraction to assess the microfibril angle of green and dry Eucalyptus grandis wood
    Naiara Conceição Marques de Souza
    José Tarcísio Lima
    Bruno Charles Dias Soares
    Trees, 2022, 36 : 191 - 197
  • [9] The possible role of microfibril angle of Hemp fibre during fatigue tests and its determination using Wide-Angle X-ray diffraction
    Placet, V.
    Bouali, A.
    Perre, P.
    MATERIAUX & TECHNIQUES, 2011, 99 (06): : 683 - 689
  • [10] NOMOGRAPHS FOR THE DETERMINATION OF WAVELENGTH FOR HIGHEST ANGLE X-RAY DIFFRACTION