Non-destructive detection of surface-bond defects in carbon composite-strengthened concrete structures

被引:2
|
作者
Helmerich, Rosemarie [1 ]
Milmann, Boris [1 ]
Woestmann, Jens [1 ]
机构
[1] BAM Fed Inst Mat Res & Testing, D-12205 Berlin, Germany
关键词
non-destructive testing; composite materials; durability; concrete bridges; strengthening; inspection;
D O I
10.1080/15732479.2013.879322
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For almost 15 years, carbon fibre-reinforced polymer (CFRP) plates and sheets have been used for strengthening and repair of civil engineering structures. CFRP plates were applied to upgrade structures for change in use or increasing traffic load. CFRP laminates have also been used to repair deteriorated structures such as multi-storey parking or bridges. The execution quality and condition of the strengthening measure in terms of bond integrity were neither monitored nor tested systematically. Inspectors eventually applied simple hammer knocking during regular main inspection for subjective noise distinction as a measure for eventual insufficient bond. This paper presents the feasibility and the limitations of low-frequency transversal ultrasonic waves with dry-coupling point-contact sensors for inspection and defect detection between CFRP laminate and concrete surfaces. The German Centre of Competence in Civil Engineering (DIBt) has initiated a national research project [Helmerich et al. (2012). Condition analysis of bonded CFRP-applications on concrete structures by means of non-destructive testing [in German: Zustandsuntersuchung von CFK-Klebeverstarkungen an Betonbauteilen mittels zerstorungsfreier Prufung (ZfP)]. Final, internal project report], carried out at the Federal Institute for Materials Research and Testing (BAM), Germany. The aim of the project was to present a potential non-destructive testing method for bond defect detection as a measure for the durability of the strengthening system more than 10years after application.
引用
收藏
页码:3 / 14
页数:12
相关论文
共 50 条
  • [1] Mechanical performance of composite-strengthened concrete structures
    Lau, KT
    Zhou, LM
    COMPOSITES PART B-ENGINEERING, 2001, 32 (01) : 21 - 31
  • [2] Nondestructive inspection of composite-strengthened concrete structures
    Newman, J
    Zweben, C
    47TH INTERNATIONAL SAMPE SYMPOSIUM AND EXHIBITION, VOL 47, BOOKS 1 AND 2: AFFORDABLE MATERIALS TECHNOLOGY-PLATFORM TO GLOBAL VALUE AND PERFORMANCE, 2002, : 691 - 702
  • [3] Non-Destructive Detection of Defects in Composite Boat Hulls
    Suratkar, A. S.
    Sajjadi, A. Y.
    Mitra, K.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 9, 2012, : 633 - 638
  • [4] NON-DESTRUCTIVE INSPECTION OF SURFACE DEFECTS IN CYLINDRICAL STRUCTURES
    Du, Jikai
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017, VOL 9, 2018,
  • [5] Non-Destructive Evaluation of Defects and Damage in Composite Materials and Structures
    Bhat, M. R.
    JOURNAL OF THE INDIAN INSTITUTE OF SCIENCE, 2013, 93 (04) : 751 - 765
  • [6] Destructive and Non-destructive Testing of Concrete Structures
    Malek, Jedidi
    Kaouther, Machta
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2014, 8 (04) : 432 - 441
  • [7] Destructive and non-destructive testing of concrete structures
    Malek, Jedidi, 1600, Jordan University of Science and Technology (08):
  • [8] Carbon fiber reinforced concrete for smart structures capable of non-destructive flaw detection
    Chen, Pu-Woei
    Chung, D.D.L.
    Smart Materials and Structures, 1993, 2 (01)
  • [9] Use of surface waves for the non-destructive testing of concrete structures
    Abraham, O.
    Côte, Ph.
    Pedersen, H.
    Hevin, G.
    Kergadallan, X.
    Insight: Non-Destructive Testing and Condition Monitoring, 2000, 42 (07): : 444 - 446
  • [10] Strain monitoring in composite-strengthened concrete structures using optical fibre sensors
    Lau, KT
    Chan, CC
    Zhou, LM
    Jin, W
    COMPOSITES PART B-ENGINEERING, 2001, 32 (01) : 33 - 45