Target volume coverage and dose to organs at risk in prostate cancer patients

被引:2
|
作者
Huettenrauch, P. [1 ,2 ]
Witt, M. [1 ,2 ]
Wolff, D. [1 ]
Bosold, S. [1 ]
Engenhart-Cabillic, R. [1 ,3 ]
Sparenberg, J. [1 ]
Vorwerk, H. [3 ]
Zink, K. [1 ,2 ,3 ]
机构
[1] Univ Klinikum Giessen Marburg GmbH, Klin Strahlentherapie, D-35392 Giessen, Germany
[2] Tech Hsch Mittelhessen, Inst Med Phys & Strahlenschutz, Giessen, Germany
[3] Univ Klinikum Giessen Marburg GmbH, Klin Strahlentherapie & Radioonkol, D-35392 Giessen, Germany
关键词
Adaptive radiotherapy; Cone-beam computed tomography; Prostate cancer; Dose recalculation; Image-guided radiation therapy; MODULATED RADIOTHERAPY IMRT; ISOCENTER CORRECTION; IMAGE; OPTIMIZATION;
D O I
10.1007/s00066-013-0483-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
On the basis of correct Hounsfield unit to electron density calibration, cone-beam computed tomography (CBCT) data provide the opportunity for retrospective dose recalculation in the patient. Therefore, the consequences of translational positioning corrections and of morphological changes in the patient anatomy can be quantified for prostate cancer patients. The organs at risk were newly contoured on the CBCT data sets of 7 patients so as to evaluate the actual applied dose. The daily dose to the planning target volume (PTV) was recalculated with and without the translation data, which result from the real patient repositioning. A CBCT-based dose recalculation with uncertainties less than 3 % is possible. The deviations between the planning CT and the CBCT without the translational positioning correction vector show an average dose difference of -aEuro parts per thousand 8 % inside the PTV. An inverse proportional relation between the mean bladder dose and the actual volume of the bladder could be established. The daily applied dose to the rectum is about 1-54 % higher than predicted by the planning CT. A dose calculation based on CBCT data is possible. The daily positioning correction of the patient is necessary to avoid an underdosage in the PTV. The new contouring of the organs at risk- the bladder and rectum-allows a better appraisal to be made of the total applied dose to these organs.
引用
收藏
页码:310 / 316
页数:7
相关论文
共 50 条
  • [1] Target volume coverage and dose to organs at risk in prostate cancer patients - dose calculation on daily cone-beam CT data sets
    Huettenrauch, P.
    Witt, M.
    Wolff, D.
    Bosold, S.
    Engenhart-Cabillic, R.
    Sparenberg, J.
    Vorwerk, H.
    Zink, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 : 42 - 42
  • [2] Impact of observer delineation variation on target coverage and dose to organs at risk in nasopharyngeal cancer patients
    Serra, NP
    van Asselen, B
    Steenbakkers, R
    Duppen, J
    van de Geer, J
    van Herk, M
    Rasch, C
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S6 - S6
  • [3] Impact of observer delineation variation on target coverage and dose to organs at risk in nasopharyngeal cancer patients
    Pimentel Serra, N.
    van Asselen, B.
    Steenbakkers, R.
    Duppen, J.
    van de Geer, J.
    van Herk, M.
    Rasch, C.
    EJC SUPPLEMENTS, 2005, 3 (02): : 289 - 289
  • [4] Volume Dose to Organs at Risk in Radiation Therapy for Prostate Cancer at the Tomotherapy
    Wilhelm-Buchstab, T.
    Muedder, T.
    Garbe, S.
    Schoroth, F.
    Simon, B.
    Luetter, C.
    Leitzen, C.
    Schueller, H.
    Schild, H. H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 114 - 114
  • [5] Tabletop influence on the coverage of the target volume and burden of risk organs
    Wagner, D. M.
    Vorwerk, H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 165 - 166
  • [6] Impact of CBCT frequency on target coverage and dose to the organs at risk in adjuvant breast cancer radiotherapy
    Kai J. Borm
    Yannis Junker
    Mathias Düsberg
    Michal Devečka
    Stefan Münch
    Hendrik Dapper
    Markus Oechsner
    Stephanie E. Combs
    Scientific Reports, 11
  • [7] Impact of CBCT frequency on target coverage and dose to the organs at risk in adjuvant breast cancer radiotherapy
    Borm, Kai J.
    Junker, Yannis
    Duesberg, Mathias
    Devecka, Michal
    Muench, Stefan
    Dapper, Hendrik
    Oechsner, Markus
    Combs, Stephanie E.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] Dose Coverage and Dose to Organs at Risk for GBM Patients Treated with Gammatile
    Adhikari, T.
    Alshreef, A. A.
    Ferreira, C.
    MEDICAL PHYSICS, 2024, 51 (10) : 7763 - 7764
  • [9] Influence of the dose-volume stress of risk organs on toxicity in percutaneous radiotherapy of prostate cancer
    Pinkawa, M
    Fischedick, K
    Asadpour, B
    Piroth, MD
    Schmidt, M
    Schmachtenberg, A
    Eble, MJ
    STRAHLENTHERAPIE UND ONKOLOGIE, 2005, 181 : 7 - 7
  • [10] Target coverage and organs at risk dose in hypofractionated salvage radiotherapy after prostatectomy
    Staal, Floor H. E.
    Janssen, Jorinde
    Krishnapillai, Sajee
    Langendijk, Johannes A.
    Both, Stefan
    Brouwer, Charlotte L.
    Aluwini, Shafak
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31