Purpose. To investigate spatial summation for motion displacement of line stimuli as a function of line length, line number and line separation. Method: A video display under PC control was used to present horizontal line stimuli of either a single E line or triple lines separated by 8, 14, 27 or 54 min arc. Two experienced normal subjects were tested at -27,3 eccentricity with peripheral refraction corrected. Five presentations of each of seven motion displacements were made between 0-24 min arc. Stimulus presentations consisted of three oscillations, duration of 200 msec per cycle. Contrast was maintained constant at 84%. Each parameter was tested three times, frequency of seeing curves (FOS) were obtained and 50% seen threshold calculated by probit analysis. Results: Mean thresholds (min arc) are summarized by chart opposite. Conclusions: Equivalent displacement thresholds were found for equivalent lines whether single or distributed amongst three shorter lines, indicating spatial summation. This principal may be used to predict motion displacement thresholds when testine, within these target dimensions.
引用
收藏
页码:335 / 340
页数:6
相关论文
共 50 条
  • [1] SINGLE-LINE MILL MATCHES MULTI-LINE PRODUCTIVITY
    WEISS, G
    CANADIAN FOREST INDUSTRIES, 1977, 97 (03) : 38 - 39
  • [3] EFFECT OF LENGTH DIFFERENCES BETWEEN CORRESPONDING LINES ON STEREOPSIS FROM SINGLE AND MULTI-LINE STIMULI
    FRISBY, JP
    JULESZ, B
    VISION RESEARCH, 1976, 16 (01) : 83 - 87
  • [4] Spatial Coherence Based Beamforming in Multi-Line Transmit Echocardiography
    Matrone, Giulia
    Ramalli, Alessandro
    D'hooge, Jan
    Tortoli, Piero
    Magenes, Giovanni
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [5] Multi-line spectropolarimetry at THEMIS
    Paletou, F
    Molodij, G
    ADVANCED SOLAR POLARIMETRY: THEORY, OBSERVATION, AND INSTRUMENTA TION, 2001, 236 : 9 - 15
  • [6] Multi-Line TRL Revisited
    Rolain, Yves
    Ishteva, Mariya
    Van Nechel, Evi
    Ferranti, Francesco
    2015 85TH ARFTG MICROWAVE MEASUREMENT CONFERENCE, 2015,
  • [7] DEPLOYING MULTI-LINE SALESMEN
    STICKNEY, RW
    HARVARD BUSINESS REVIEW, 1960, 38 (02) : 110 - 112
  • [8] THEMIS multi-line spectropolarimetry
    Paletou, F
    Molodij, G
    MAGNETIC FIELDS ACROSS THE HERTZSPRUNG-RUSSELL DIAGRAM, 2001, 248 : 617 - 620
  • [9] MULTI-LINE LASER PHOTOCOAGULATOR
    BEHRENDT, T
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1970, 69 (05) : 885 - &
  • [10] Reduction of address period in PDPs by combined single-line and multi-line scanning method
    Fujii, Masato
    Suzuki, Chiharu
    Shiga, Tomokazu
    Kyokai Joho Imeji Zasshi/Journal of the Institute of Image Information and Television Engineers, 2014, 68 (10):