Airflow management in a liquid-cooled data center

被引:0
|
作者
Cader, Tahir [1 ]
Westra, Levi [1 ]
Regimbal, Kevin [2 ]
Mooney, Ryan [2 ]
机构
[1] Isothermal Syst Res, High Performance Comp Grp, Liberty Lake, WA 99019 USA
[2] Pacific Northwest Lab, MSCF Operat EMSL, Richland, WA USA
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Electronics densification is continuing at an unrelenting pace at the server rack and facility levels. With increasing facility density levels, airflow management has become a major challenge and concern. Hot spots, air short-circuiting, and inadequate tile airflow are a few of the issues that are complicating airflow management. This paper focuses on a thermal management approach that simplifies facility airflow management in a cost-effective and efficient manner Implementation of the technology was undertaken with the DOE's Pacific Northwest National Laboratory. Under the effort, a single 8.2 kW rack of HP rx2600 servers was converted from air cooling to liquid cooling. The liquid-cooling solution employs spray modules that indirectly cool the processors and remove the processor heat load directly to the facility water and not the facility air An infrared camera was used to measure the temperature distributions over the rear doors of the liquid-cooled rack and several air-cooled racks, as well as the internal areas of a liquid-cooled and an air-cooled server A tile hood was also used to measure the airflow rate out of all of the perforated tiles in the data center The air exiting an 8.2 kWair-cooled rack located in a best-case facility location reached a maximum of 34 degrees C and the air exiting an air-cooled rack located in a worst-case location reached a maximum of 44 degrees C, while the air exiting the liquid-cooled rack was 10 degrees C to 20 degrees C cooler reaching a maximum of 24 degrees C. The air is delivered to the tiles at approximately 14 degrees C. The thermal gradient over the air-cooled racks approximated 10 degrees C (hottest servers at the top), while that over the liquidcooled rack was less than half and on the order of 3 degrees C-4 degrees C. The image of the internal areas of the air-cooled server showed some significant hot spots on the power pods and memory, while these were significantly diminished for the liquid-cooled server The tile airflow measurements revealed that the vast majority of the tiles delivered approximately 725 cfm, with five tiles delivering between 1,300 and 1,480 cfm. This paper provides further details on the study and will analyze the manner in which facility airflow management complexity and cost can be reduced for a liquid-cooled facility.
引用
收藏
页码:220 / +
页数:3
相关论文
共 50 条
  • [1] Liquid-Cooled IT Equipment In Data Centers
    Shell, Vali
    Carter, Bill
    Zeighami, Roy
    Smith, Susan F.
    Steinbrecher, Robin
    [J]. ASHRAE JOURNAL, 2015, 57 (12) : 12 - 22
  • [2] Performance analysis and optimization of free cooling strategies for a liquid-cooled data center
    Weinan Zhou
    Qin Sun
    Weimin Luo
    Wei Xiao
    Pengfei Cui
    Wei Wu
    Kaijun Dong
    [J]. Building Simulation, 2023, 16 : 1317 - 1330
  • [3] Performance analysis and optimization of free cooling strategies for a liquid-cooled data center
    Zhou, Weinan
    Sun, Qin
    Luo, Weimin
    Xiao, Wei
    Cui, Pengfei
    Wu, Wei
    Dong, Kaijun
    [J]. BUILDING SIMULATION, 2023, 16 (08) : 1317 - 1330
  • [4] Performance Enhancement of Single-Phase Immersion Liquid-Cooled Data Center Servers
    GE Junlei
    XIA Feifan
    ZHANG Chengbin
    HUANG Yongping
    [J]. Journal of Thermal Science., 2024, 33 (05) - 1772
  • [5] Liquid-Cooled System
    Carter, Thomas P.
    [J]. ASHRAE JOURNAL, 2016, 58 (02) : 12 - 14
  • [6] Performance Enhancement of Single-Phase Immersion Liquid-Cooled Data Center Servers
    Ge, Junlei
    Xia, Feifan
    Zhang, Chengbin
    Huang, Yongping
    [J]. JOURNAL OF THERMAL SCIENCE, 2024, 33 (05) : 1757 - 1772
  • [7] THERMAL MANAGEMENT OF AIR-COOLED AND LIQUID-COOLED MULTICHIP MODULES
    BARCOHEN, A
    [J]. IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1987, 10 (02): : 159 - 175
  • [8] Current Status and Challenges for Liquid-Cooled Data Centers
    Chen, Hongwei
    Li, Dong
    [J]. FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [9] THERMODYNAMIC ANALYSIS OF FULL LIQUID-COOLED DATA CENTERS
    Bhalerao, A.
    Wemhoff, A. R.
    [J]. INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2015, VOL 1, 2015,
  • [10] Experimental Investigation of Direct Attach Microprocessors in a Liquid-Cooled Chiller-less Data Center
    Schultz, Mark
    Gaynes, Michael
    Parida, Pritish
    Chainer, Timothy
    [J]. 2014 IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2014, : 729 - 735