Novel Screw Head Design of Pedicle Screw for Reducing the Correction Loss in the Patients With Thoracolumbar Vertebral Fractures A Biomechanical Study

被引:8
|
作者
Ye, Bin [1 ]
Yan, Ming [1 ]
Zhu, Huiyang [1 ]
Duan, Wei [1 ]
Hu, Xueyu [1 ]
Ye, Zhengxu [1 ]
Luo, Zhuojing [1 ]
机构
[1] Fourth Mil Med Univ, Xijing Hosp, Dept Orthoped, 169 West Changle Rd, Xian 710032, Shaanxi, Peoples R China
关键词
biomechanical study; correction loss; monoplanar pedicle screws; thoracolumbar vertebral fractures; POSTERIOR SPINAL-FUSION; FIXATION; INSTRUMENTATION;
D O I
10.1097/BRS.0000000000001808
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A biomechanical study. Objective. To study the different biomechanical property among fixed-axis, monoplanar and polyaxial screws in the static and dynamic tests. Summary of Background Data. Correction loss is a common phenomenon in the patients with thoracolumbar vertebral fractures who underwent the posterior pedicle screw fixation. The incidence varies with the kinds of fixation instrumentation used. There is higher incidence in polyaxial pedicle screws group than in fixed-axis pedicle screws. Monoplanar pedicle screws, which are mobile in the axial plane but fixed in the sagittal plane, can be a better fixation instrumentation for thoracolumbar vertebral fractures in theory. Methods. A total of 30 porcine spinal units (L2-L4) were used for the static and dynamic tests, which were randomized into six groups (A1, A2, A3, B1, B2, and B3). Static test was performed in A1, A2, and A3. In this test, fixed-axis, monoplanar, and polyaxial screws were performed in A1, A2, and A3, respectively. The ultimate load was noted after tested. In addition, dynamic test was performed in B1, B2, and B3, used fixed-axis, monoplanar, and polyaxial screws, respectively. Correction loss (head-shank angle shift and anterior vertebral body height shift) was obtained and analyzed in each mode. Results. In static test, fixed-axis and monoplanar screws had significantly higher ultimate load than polyaxial screws (P<0.05) and fixed-axis screws had a little higher ultimate load than monoplanar screws (P<0.05). In dynamic test, correction loss was minimal in fixed-axis screws, medium in monoplanar screws, and maximal in polyaxial screws. However, the differences were statistically significant in all comparisons but not in the comparison of fixed-axis and monoplanar screws (P>0.05). Conclusion. The findings from the current study suggest that monoplanar screws can significantly increase the stiffness in axial direction compared with polyaxial screws, and reduce the risks of correction loss. For thoracolumbar vertebral fractures, monoplanar screw is a better optional instrumentation for minimally invasive surgery.Level of Evidence: N/A
引用
收藏
页码:E379 / E384
页数:6
相关论文
共 50 条
  • [1] Novel uniplanar pedicle screw systems applied to thoracolumbar fractures: a biomechanical study
    Jiang, Yuheng
    Cui, Xiang
    Ji, Wei
    Li, Jia
    Shi, Yanli
    Zhao, Jingxin
    Wang, Junsong
    Tang, Peifu
    Zhang, Wei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [2] Biomechanical effects of pedicle screw adjustments on the thoracolumbar burst fractures
    SHANG Jian
    LING Xiao-dong
    LIU Yuan-chao
    LIU Wei
    XIAO Xi-gang
    YUAN Shao-hui
    中华医学杂志(英文版), 2013, 126 (02) : 300 - 305
  • [3] Biomechanical effects of pedicle screw adjustments on the thoracolumbar burst fractures
    Jian, Shang
    Xiao-dong, Ling
    Yuan-chao, Liu
    Wei, Liu
    Xi-gang, Xiao
    Shao-hui, Yuan
    CHINESE MEDICAL JOURNAL, 2013, 126 (02) : 300 - 305
  • [4] Biomechanical Analysis of Pedicle Screw Fixation for Thoracolumbar Burst Fractures
    McDonnell, Matthew
    Shah, Kalpit N.
    Paller, David J.
    Thakur, Nikhil A.
    Koruprolu, Sarath
    Palumbo, Mark A.
    Daniels, Alan H.
    ORTHOPEDICS, 2016, 39 (03) : E514 - E518
  • [5] Pedicle screw instrumentation of thoracolumbar burst fractures: Biomechanical evaluation of screw configuration with pedicle screws at the level of the fracture
    Bolesta, Michael J.
    Caron, Troy
    Chinthakunta, Suresh R.
    Vazifeh, Pedram Niknam
    Khalil, Saif
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2012, 6 : 200 - 205
  • [6] Pedicle screw fixation with a novel external frame for thoracolumbar fractures: A comparative study
    Nie, Shaobo
    Ji, Hui
    Chen, Hua
    Liang, Xiangdang
    Zhang, Qun
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 25 : 60 - 65
  • [7] Effection of monoplanar pedicle screw on facet joint degeneration in thoracolumbar vertebral fractures
    Bin Ye
    Zhengxu Ye
    Ming Yan
    Peipei Huang
    Zhipeng Tu
    Zhe Wang
    Zhuojing Luo
    Xueyu Hu
    BMC Musculoskeletal Disorders, 23
  • [8] Effection of monoplanar pedicle screw on facet joint degeneration in thoracolumbar vertebral fractures
    Ye, Bin
    Ye, Zhengxu
    Yan, Ming
    Huang, Peipei
    Tu, Zhipeng
    Wang, Zhe
    Luo, Zhuojing
    Hu, Xueyu
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [9] Design and biomechanical study of a modified pedicle screw
    刘涛
    郑文杰
    李长青
    刘国栋
    周跃
    中华创伤杂志(英文版), 2010, (04)
  • [10] Design and biomechanical study of a modified pedicle screw
    Liu Tao
    Zheng Wen-jie
    Li Chang-qing
    Liu Guo-dong
    Zhou Yue
    CHINESE JOURNAL OF TRAUMATOLOGY, 2010, 13 (04) : 222 - 228