Intra- and interobserver agreement for fetal cerebral measurements in 3D-ultrasonography

被引:5
|
作者
Albers, Maria E. W. A. [1 ,2 ]
Buisman, Erato T. I. A. [3 ]
Kahn, Rene S. [2 ,4 ]
Franx, Arie [1 ]
Onland-Moret, N. Charlotte [5 ]
de Heus, Roel [1 ]
机构
[1] Univ Utrecht, Univ Med Ctr Utrecht, Div Woman & Baby, Utrecht, Netherlands
[2] Univ Utrecht, Univ Med Ctr Utrecht, Brain Ctr Rudolf Magnus, Utrecht, Netherlands
[3] Jeroen Bosch Hosp, Dept Obstet & Gynaecol, sHertogenbosch, Netherlands
[4] Icahn Sch Med Mt Sinai, Dept Psychiat, New York, NY 10029 USA
[5] Univ Utrecht, Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
关键词
brain; cerebrum; cerebellum; fetal; intraobserver agreement; interobserver agreement; three dimensional; ultrasound; 3-DIMENSIONAL ULTRASOUND; OFFLINE ANALYSIS; VOLUME; BRAIN; DISEASE; REPRODUCIBILITY; RELIABILITY; DIAGNOSIS; DATASETS; FETUSES;
D O I
10.1002/hbm.24076
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The aim of this study is to evaluate intra- and interobserver agreement for measurement of intracranial, cerebellar, and thalamic volume with the Virtual Organ Computer-aided AnaLysis (VOCAL) technique in three-dimensional ultrasound images, in comparison to two-dimensional measurements of these brain structures. Three-dimensional ultrasound images of the brains of 80 fetuses at 20-24 weeks' gestational age were obtained from YOUth, a Dutch prospective cohort study. Two observers performed offline measurement of the occipitofrontal diameter, intracranial volume, transcerebellar diameter, cerebellar volume, and thalamic width, area, and volume, independently. VOCAL was used for calculation of the volumes. The two-way random, single measures intraclass correlation coefficient (ICC) was used for analysis of agreement and Bland-Altman plots were configured. Intra- and interobserver agreement was almost perfect for occipitofrontal diameter (intra ICC 0.88, 95% CI 0.82-0.92; inter ICC 0.91, 95% CI 0.85-0.94), intracranial volume (intra ICC 0.96, 95% CI 0.91-0.98; inter ICC 0.97, 95% CI 0.96-0.98) and transcerebellar diameter (intra ICC 0.91, 95% CI 0.86-0.94; inter ICC 0.86, 95% CI 0.78-0.910). For cerebellar volume, the intraobserver agreement was almost perfect (0.85, 95% CI 0.76-0.90), whereas the interobserver agreement was substantial (0.75, 95% CI 0.44-0.88). Agreement was only moderate for thalamic measurements. Bland-Altman plots for the volume measurements are normally distributed with acceptable mean differences and 95% limits of agreement. The intra- and interobserver agreement of the measurement of intracranial and cerebellar volume with VOCAL was almost perfect. These measurements are therefore reliable, and can be used to investigate fetal brain development. Thalamic measurements are not reliable enough.
引用
收藏
页码:3277 / 3284
页数:8
相关论文
共 50 条
  • [1] An offline 3D-ultrasonography intra- and interobserver agreement study of fetal cerebral structures
    Buisman, E. T.
    Albers, M. E.
    Onland-Moret, N. C.
    Kahn, R. S.
    Franx, A.
    de Heus, R.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 36 - 36
  • [2] Intra- and interobserver variability in fetal ultrasound measurements
    Sarris, I.
    Ioannou, C.
    Chamberlain, P.
    Ohuma, E.
    Roseman, F.
    Hoch, L.
    Altman, D. G.
    Papageorghiou, A. T.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (03) : 266 - 273
  • [3] Intra- and interobserver agreement of rectal cancer staging with MRI
    Kilickap, Gulsum
    Dolek, Betul Akdal
    Ercan, Karabekir
    [J]. ACTA RADIOLOGICA, 2023, 64 (05) : 1747 - 1754
  • [4] Intra- and interobserver errors in facial flatness measurements
    Hanihara, T
    Dodo, Y
    Kondo, O
    Nara, T
    Doi, N
    Sensui, N
    [J]. ANTHROPOLOGICAL SCIENCE, 1999, 107 (01) : 25 - 39
  • [5] Intra- and Interobserver Variability in CT Measurements in Oncology
    McErlean, Aoife
    Panicek, David M.
    Zabor, Emily C.
    Moskowitz, Chaya S.
    Bitar, Richard
    Motzer, Robert J.
    Hricak, Hedvig
    Ginsberg, Michelle S.
    [J]. RADIOLOGY, 2013, 269 (02) : 450 - 458
  • [6] Intra- and Interobserver Agreement in Hallux Valgus Angle Measurements on Weightbearing and Non-Weightbearing Radiographs
    van der Woude, Pieter
    Keizer, Stefan B.
    Wever-Korevaar, Martine
    Thomassen, Bregje J. W.
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2019, 58 (04): : 706 - 712
  • [7] Transrectal ultrasonography in male subfertility patients: an intra- and interobserver study
    Schipper, RA
    Trum, JW
    Messelink, EJ
    van der Veen, F
    Kurth, KH
    [J]. UROLOGICAL RESEARCH, 2001, 29 (01): : 57 - 59
  • [8] Transrectal ultrasonography in male subfertility patients: an intra- and interobserver study
    R. A. Schipper
    J. W. Trum
    E. J. Messelink
    F. van der Veen
    K. H. Kurth
    [J]. Urological Research, 2001, 29 : 57 - 59
  • [9] Ultrasound assessment of placental lakes and calcifications and their intra- and interobserver agreement
    Schiffer, V.
    De Cubber, L.
    van Haren, A.
    van Kuijk, S.
    Spaanderman, M.
    Al Nasiry, S.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 219 - 219
  • [10] Intra- and interobserver agreement on cervical volume and flow indices during pregnancy using transvaginal 3-dimensional ultrasonography and Doppler angiography
    Basgul, Alin
    Kavak, Zehra N.
    Bakird, Nadi
    Gokaslan, Husnu
    [J]. INTERNATIONAL JOURNAL OF FERTILITY AND WOMENS MEDICINE, 2006, 51 (06) : 256 - 261