Optimization of femtosecond laser-constructed clear corneal wound sealability for cataract surgery

被引:3
|
作者
Benard-Seguin, Etienne [1 ]
Bostan, Cristina [2 ]
Fadous, Raphaelle [2 ]
Sylvestre-Bouchard, Antoine [1 ,2 ]
Weerasekera, Hasitha Jaliya de Alwis [1 ]
Giguere, Charles-Edouard [3 ,4 ]
Harasymowycz, Paul [1 ,2 ]
Brunette, Isabelle [1 ,2 ]
机构
[1] Maisonneuve Rosemont Hosp, Res Ctr, Montreal, PQ, Canada
[2] Univ Montreal, Dept Ophthalmol, Montreal, PQ, Canada
[3] Inst Univ Sante Mentale Montreal, Ctr Rech, Montreal, PQ, Canada
[4] Clin Bellevue, Montreal, PQ, Canada
来源
关键词
MORPHOLOGIC FEATURES; INCISION; ENDOPHTHALMITIS; PHACOEMULSIFICATION;
D O I
10.1097/j.jcrs.0000000000000336
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the sealability of femtosecond laser (FSL)-assisted corneal incisions (CIs) with that of triplanar manual (M)-CIs and to determine FSL wound parameters minimizing leakage. Setting: Private practice. Design: Phase IV, single-surgeon, retrospective cohort study. Methods: One eye per patient was included. Two groups defined by the main wound (FSL-CI or M-CI) were compared for leakage, inferred by placement of a suture at the end of surgery. Leakage in FSL-CIs was analyzed as a function of customizable wound parameters: anterior plane depth (APD), posterior plane depth (PPD), anterior side-cut angle (ASCA), and posterior side-cut angle (PSCA). The risk of leakage of FSL-CIs with optimal and nonoptimal parameters was further compared with that of M-CIs. Results: A total of 1100 eyes (757 [68.8%] FSL-CI; 343 [31.2%] M-CI) were included. Wound leakage occurred in 133 FSL-CI (17.6%) and 30 M-CI eyes (8.7%) (P <.001). FSL wound parameters associated with the lowest risk of leakage were 60% APD, 70% PPD, 120 degrees ASCA, and 70 degrees PSCA. FSL-CIs constructed with at least 3 optimal parameters (60% APD, 70% PPD, and 120 degrees ASCA) had a similar risk of leakage toM-CIs (odds ratio [OR], 1.1; 95% CI, 0.5-2.3). FSL-CIs with suboptimal parameters had twice the risk of leakage of M-CIs (OR, 2.0; 95% CI, 1.1-3.8). Conclusions: Overall, FSL-CIs leaked more than M-CIs. However, FSL-CIs with optimized wound profiles had an equivalent risk of leakage to M-CIs. Wound parameter customization is an asset of FSL technology that allows optimization of FSL-CI sealability. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS.
引用
收藏
页码:1611 / 1617
页数:7
相关论文
共 50 条
  • [1] Comparison of Wound Sealability Between Femtosecond Laser-Constructed and Manual Clear Corneal Incisions in Patients Undergoing Cataract Surgery: A Pilot Study
    Uy, Harvey Siy
    Shah, Sunil
    Packer, Mark
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (11) : 744 - +
  • [2] Femtosecond Laser Versus Manual Clear Corneal Incision in Cataract Surgery
    Mastropasqua, Leonardo
    Toto, Lisa
    Mastropasqua, Alessandra
    Vecchiarino, Luca
    Mastropasqua, Rodolfo
    Pedrotti, Emilio
    Di Nicola, Marta
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (01) : 27 - U32
  • [3] New technique for femtosecond laser creation of clear corneal incisions for cataract surgery
    Serrao, Sebastiano
    Giannini, Daniela
    Schiano-Lomoriello, Domenico
    Lombardo, Giuseppe
    Lombardo, Marco
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (01): : 80 - 86
  • [4] Evaluation of Femtosecond Laser-assisted Clear Corneal and Paracentesis Incisions for Cataract Surgery
    Hill, James E.
    Gray, Brad
    Huang, Ling
    Wiley, William F.
    Waltz, Kevin L.
    Garufis, Carrie
    Connolly, LeAnne
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [5] Preliminary investigation of corneal wavefront aberration following femtosecond laser clear corneal incision for cataract surgery
    Serrao, Sebastiano
    Lombardo, Giuseppe
    Schiano-Lomoriello, Domenico
    Rosati, Marianna
    Lombardo, Marco
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (06) : 842 - 849
  • [6] Femtosecond laser-assisted cataract surgery versus 2.2 mm clear corneal phacoemulsification
    Ranjini, H.
    Murthy, Praveen R.
    Murthy, Gowri J.
    Murthy, Vinay R.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (10) : 942 - 948
  • [7] Clear corneal cataract surgery
    Fine, IH
    Hoffman, RS
    [J]. OPHTHALMIC SURGERY AND LASERS, 1998, 29 (10): : 822 - 831
  • [8] Comparison of surgically induced astigmatism between femtosecond laser and manual clear corneal incisions for cataract surgery
    Diakonis, Vasilios F.
    Yesilirmak, Nilufer
    Cabot, Florence
    Kankariya, Vardhaman P.
    Kounis, George A.
    Warren, Daniel
    Sayed-Ahmed, Ibrahim O.
    Yoo, Sonia H.
    Donaldson, Kendall
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2075 - 2080
  • [9] Wound closure and tissue adhesives in clear corneal incision cataract surgery
    Tong, Amy Y.
    Gupta, Preeya K.
    Kim, Terry
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (01) : 14 - 18
  • [10] Wavelength Optimization in Femtosecond Laser Corneal Surgery
    Crotti, Caroline
    Deloison, Florent
    Alahyane, Fatima
    Aptel, Florent
    Kowalczuk, Laura
    Legeais, Jean-Marc
    Peyrot, Donald A.
    Savoldelli, Michele
    Plamann, Karsten
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3340 - 3349