xCELLigence system for real-time label-free monitoring of growth and viability of cell lines from hematological malignancies

被引:60
|
作者
Martinez-Serra, Jordi [1 ]
Gutierrez, Antonio [1 ]
Munoz-Capo, Saul [1 ]
Navarro-Palou, Maria [1 ]
Ros, Teresa [1 ]
Carlos Amat, Juan [1 ]
Lopez, Bernardo [1 ]
Marcus, Toni F. [1 ]
Fueyo, Laura [2 ]
Suquia, Angela G. [2 ]
Gines, Jordi [3 ]
Rubio, Francisco [1 ]
Ramos, Rafael [4 ]
Besalduch, Joan [1 ]
机构
[1] Univ Hosp Son Espases, Dept Hematol, Palma De Mallorca, Balearic Island, Spain
[2] Univ Hosp Son Espases, Dept Clin Anal, Palma De Mallorca, Balearic Island, Spain
[3] Univ Hosp Son Espases, Dept Pharm, Palma De Mallorca, Balearic Island, Spain
[4] Univ Hosp Son Espases, Dept Pathol, Palma De Mallorca, Balearic Island, Spain
来源
ONCOTARGETS AND THERAPY | 2014年 / 7卷
关键词
real-time cell analysis; drug discovery; leukemia; lymphoma; MINIMAL RESIDUAL DISEASE; BONE-MARROW MICROENVIRONMENT; DRUG-RESISTANCE; BREAST-CANCER; FIBRONECTIN; LEUKEMIA; VLA-4; CONTRIBUTOR; INHIBITION;
D O I
10.2147/OTT.S62887
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The xCELLigence system is a new technological approach that allows the real-time cell analysis of adherent tumor cells. To date, xCELLigence has not been able to monitor the growth or cytotoxicity of nonadherent cells derived from hematological malignancies. The basis of its technology relies on the use of culture plates with gold microelectrodes located in their base. We have adapted the methodology described by others to xCELLigence, based on the pre-coating of the cell culture surface with specific substrates, some of which are known to facilitate cell adhesion in the extracellular matrix. Pre-coating of the culture plates with fibronectin, compared to laminin, collagen, or gelatin, significantly induced the adhesion of most of the leukemia/lymphoma cells assayed (Jurkat, L1236, KMH2, and K562). With a fibronectin substrate, nonadherent cells deposited in a monolayer configuration, and consequently, the cell growth and viability were robustly monitored. We further demonstrate the feasibility of xCELLigence for the real-time monitoring of the cytotoxic properties of several antineoplastic agents. In order to validate this technology, the data obtained through real-time cell analysis was compared with that obtained from using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide method. This provides an excellent label-free tool for the screening of drug efficacy in nonadherent cells and discriminates optimal time points for further molecular analysis of cellular events associated with treatments, reducing both time and costs.
引用
收藏
页码:985 / 994
页数:10
相关论文
共 50 条
  • [1] Real-time, label-free monitoring of cellular invasion and migration with the xCELLigence system
    Christopher Bird
    Shelli Kirstein
    Nature Methods, 2009, 6 (8) : v - vi
  • [2] Real-Time Label-Free Monitoring of Nanoparticle Cell Uptake
    Suutari, Teemu
    Silen, Tiina
    Sen Karaman, Didem
    Saari, Heikki
    Desai, Diti
    Kerkela, Erja
    Laitinen, Saara
    Hanzlikova, Martina
    Rosenholm, Jessica M.
    Yliperttula, Marjo
    Viitala, Tapani
    SMALL, 2016, 12 (45) : 6289 - 6300
  • [3] Real-time, label-free monitoring of cell viability based on cell adhesion measurements with an atomic force microscope
    Fang, Yang
    Riedel, Rene
    del Pino, Pablo
    Pelaz, Beatriz
    Said, Alaa Hassan
    Soliman, Mahmoud
    Pinnapireddy, Shashank R.
    Feliu, Neus
    Parak, Wolfgang J.
    Bakowsky, Udo
    Hampp, Norbert
    JOURNAL OF NANOBIOTECHNOLOGY, 2017, 15
  • [4] Real-time, label-free monitoring of cell viability based on cell adhesion measurements with an atomic force microscope
    Fang Yang
    René Riedel
    Pablo del Pino
    Beatriz Pelaz
    Alaa Hassan Said
    Mahmoud Soliman
    Shashank R. Pinnapireddy
    Neus Feliu
    Wolfgang J. Parak
    Udo Bakowsky
    Norbert Hampp
    Journal of Nanobiotechnology, 15
  • [5] The xCELLigence system for real-time and label-free analysis of neuronal and dermal cell response to Equine Herpesvirus type 1 infection
    Golke, A.
    Cymerys, J.
    Slonska, A.
    Dzieciatkowski, T.
    Chmielewska, A.
    Tucholska, A.
    Banbura, M. W.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2012, 15 (01): : 151 - 153
  • [6] Label-free and real-time monitoring of yeast cell growth by the bending of polymer microcantilever biosensors
    Liu, Yifan
    Schweizer, Lilian M.
    Wang, Wenxing
    Reuben, Robert L.
    Schweizer, Michael
    Shu, Wenmiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 621 - 626
  • [7] Label-free monitoring of T cell activation by the impedance-based xCELLigence system
    Guan, Ni
    Deng, Jiejie
    Li, Ting
    Xu, Xiao
    Irelan, Jeffrey T.
    Wang, Ming-Wei
    MOLECULAR BIOSYSTEMS, 2013, 9 (05) : 1035 - 1043
  • [8] Label-free characterization and real-time monitoring of cell uptake of extracellular vesicles
    Koponen, Annika
    Kerkela, Erja
    Rojalin, Tatu
    Lazaro-Ibanez, Elisa
    Suutari, Teemu
    Saari, Heikki O.
    Siljander, Pia
    Yliperttula, Marjo
    Laitinen, Saara
    Viitala, Tapani
    BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [9] Monitoring of cardiac cytotoxicity in real-time with the xCELLigence system
    Seiler, Alexander
    Lambernd, Silja
    Ehlich, Noushin
    Ehlich, Andreas
    Bohlen, Heribert
    Watzele, Manfred
    TOXICOLOGY LETTERS, 2009, 189 : S70 - S70
  • [10] Label-free fluorescent real-time monitoring of adenylyl cyclase
    Rhee, Hyun-Woo
    Kim, Kyoung-Shim
    Han, Pyung-Lim
    Hong, Jong-In
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2010, 20 (03) : 1145 - 1147