Ultrasound-based Navigation and 3D CT Compared in Acetabular Cup Position

被引:8
|
作者
Hasart, Olaf [1 ]
Poepplau, Berry M. [2 ]
Asbach, Patrick [3 ]
Perka, Carsten [1 ]
Wassilew, Georgi I. [1 ]
机构
[1] Charite, Charite Orthopaed Dept, Ctr Musculoskeletal Surg, D-13353 Berlin, Germany
[2] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[3] Charite, Charite Dept Radiol, D-13353 Berlin, Germany
关键词
TOTAL HIP-ARTHROPLASTY; IMAGELESS NAVIGATION; COMPUTER NAVIGATION; COMPONENT; ORIENTATION; DISLOCATION; VALIDATION; PLACEMENT; REVISION; ACCURACY;
D O I
10.3928/01477447-20090915-50
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Intraoperative landmarks are used in image-free navigation systems. The ultrasound-based navigation systems try to overcome the problems of positional deviation associated with soft tissue. Our study analyzed the accuracy of ultrasound-based navigation of cup positioning compared with postoperative 3-dimensional (3D) computed tomography scans of cup positioning. Twenty-five ultrasound-navigated total hip arthroplasties (THAs) were analyzed. The difference between the intraoperative cup orientation (navigation) and the postoperative cup position (CT) was evaluated. The average difference between intraoperative navigation and postoperative CT measurements was 2.8 degrees (SD +/- 1.8 degrees) for abduction and 2.2 degrees (SD +/- 1.6 degrees) for anteversion. Therefore, we recommend ultrasound-based navigation as an exact tool for cup positioning in THA.
引用
收藏
页码:6 / 10
页数:5
相关论文
共 50 条
  • [1] Comparison of acetabular cup position in total hip arthroplasty between ultrasound-based navigation and postoperative 3-D computer tomography
    Wassilew, G. I.
    Poepplau, B.
    Asbach, P.
    Perka, C.
    Hasart, O.
    [J]. SWISS MEDICAL WEEKLY, 2009, 139 (23-24) : 5S - 5S
  • [2] Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement
    Kalteis, T
    Handel, M
    Herold, T
    Perlick, L
    Paetzel, C
    Grifka, J
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (02) : 294 - 300
  • [3] Ultrasound-based computer navigation of the acetabular component: a feasibility study
    Wassilew, Georgi I.
    Heller, Markus O.
    Hasart, Olaf
    Perka, Carsten
    Suedhoff, Ingrid
    Janz, Viktor
    Duda, Georg N.
    Koenig, Christian
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (04) : 517 - 525
  • [4] Ultrasound-based computer navigation of the acetabular component: a feasibility study
    Georgi I. Wassilew
    Markus O. Heller
    Olaf Hasart
    Carsten Perka
    Ingrid Südhoff
    Viktor Janz
    Georg N. Duda
    Christian König
    [J]. Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 517 - 525
  • [5] 3D ultrasound-based navigation for radiofrequency thermal ablation in the treatment of liver malignancies
    Sjolie, E
    Lango, T
    Ystgaard, B
    Tangen, GA
    Hernes, TAN
    Mårvik, R
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (06): : 933 - 938
  • [6] 3D ultrasound-based navigation for radiofrequency thermal ablation in the treatment of liver malignancies
    E. Sjølie
    T. Langø
    B. Ystgaard
    G.A. Tangen
    T.A. Nagelhus Hernes
    R. Mårvik
    [J]. Surgical Endoscopy And Other Interventional Techniques, 2003, 17 : 933 - 938
  • [7] 3D Ultrasound-based patient positioning for radiotherapy
    Wang, Michael H.
    Rohling, Robert N.
    Archip, Neculai
    Clark, Brenda G.
    [J]. MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [8] Feasibility and accuracy of image guided liver resection using 3D ultrasound-based optoelectronic navigation
    Beller, S.
    Huenerbein, M.
    Lange, T.
    Eulenstein, S.
    Chopra, S.
    Schlag, P. M.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S280 - S282
  • [9] 3D ultrasound-based evaluation of lesions in the uncompressed breast
    Riis, C
    Lernevall, A
    Sorensen, FB
    Nygaard, H
    [J]. RESEARCH AND DEVELOPMENT IN BREAST ULTRASOUND, 2005, : 151 - 155
  • [10] Accuracy evaluation of a 3D ultrasound-based neuronavigation system
    Lango, T
    Bang, J
    Lindseth, F
    Hernes, TAN
    [J]. CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 63 - 68