Effect of Nanoparticles on Physico-Mechanical Properties of Flowable Dental Composite Resins

被引:3
|
作者
Al Jafary, Mohammed [1 ]
Hashem, Mohamed Ibrahim [2 ]
Al Khadhari, Majdah A. [3 ]
Alshammmery, Sara Abdullah [1 ]
Assery, Mansour K. [4 ]
机构
[1] Riyadh Elm Univ, Dept Restorat Dent, Riyadh 13244, Saudi Arabia
[2] King Saud Univ, Coll Appl Med Sci, Dent Hlth Dept, Riyadh 11433, Saudi Arabia
[3] King Abdul Aziz Med City, Jeddah 21423, Saudi Arabia
[4] Riyadh Elm Univ, Post Grad Studies & Sci Res, Riyadh 13244, Saudi Arabia
关键词
Flow Able Composites; Nanoparticles; Titanium Dioxide; Surface Roughness; Micro-Hardness; Flexural Strength; SURFACE-ROUGHNESS; FLEXURAL STRENGTH; ANTIBACTERIAL; NANOCOMPOSITE; RESTORATIVES; COLOR;
D O I
10.1166/sam.2019.3578
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The flow able dental composite resins were introduced to the dental specialty because of the advantages they possess over the conventional composite resins. The use of nanotechnology in the dentistry field is one of the growing innovation in recent years. In this work, TiO2 nanoparticles at 1% (NC1), 2% (NC2) and 3% (NC3) (w/w) concentrations were added to Tetric N Flow composite, while the unmodified composite was used as control. The developed composite was studies for functional and structural properties using FTIR and XRD, which indicated no change in the functional and structural characteristics thereby improving the mechanical properties. Round specimens were made from experimental and control composite groups for surface roughness and hardness testing; rectangular specimens were made for flexural strength testing. The surface roughness test results showed NC3 group with highest value (0.163 +/- 0.017) and the control group had lowest value (0.151 +/- 0.021). Significant difference was observed in roughness values between all the groups (P <= 0.05). The micro-hardness test results showed that NC1 had the highest value (72.5 +/- 2.6) and lowest values was observed with NC3 (54.17 +/- 1.9). Significant difference was observed in micro-hardness values between the groups except between control and NC2 group (P = 1.00). The flexural strength test results demonstrated that NC1 had the highest value (95.33 +/- 1.86) and the lowest value was seen with NC3 group (85.17 +/- 1.37). No significant differences was observed in flexural strength between control group and NC2 group (P = 0.25); NC 2 and NC3 (P = 0.073).
引用
收藏
页码:986 / 993
页数:8
相关论文
共 50 条
  • [1] Effect of Curing Time on Physico-mechanical Properties on Dental Composite
    Gupta, Mayuri
    Tyagi, A. K.
    Raula, Manoj
    [J]. JOURNAL OF POLYMER & COMPOSITES, 2022, 10 (03) : 36 - 47
  • [2] EFFECT OF DIFFERENT CLINICAL APPLICATIONS ON PHYSICO-MECHANICAL PROPERTIES OF COMPOSITE RESINS
    Gumustas, Burak
    Efes, Begum Guray
    [J]. BIOSCIENCE JOURNAL, 2018, 34 (05): : 1463 - 1471
  • [3] No-Cap Flowable Bulk-Fill Composite: Physico-Mechanical Assessment
    Alshehri, Abdullah
    Alhalabi, Feras
    Robaian, Ali
    Abuelqomsan, Mohammed A. S.
    Alshabib, Abdulrahman
    Ismail, Eman
    Alzamil, Faisal
    Alotaibi, Nawaf
    Algamaiah, Hamad
    [J]. POLYMERS, 2023, 15 (08)
  • [4] Physico-mechanical and thermal characteristics of commercially available and newly developed dental flowable composites
    Kamalak, Hakan
    Canbay, C. Aksu
    Yigit, Oktay
    Altin, Serdar
    [J]. JOURNAL OF MOLECULAR STRUCTURE, 2018, 1156 : 314 - 319
  • [5] Improving mechanical properties of flowable dental composite resin by adding silica nanoparticles
    Balos, Sebastian
    Pilic, Branka
    Petronijevic, Branislava
    Markovic, Dubravka
    Mirkovic, Sinisa
    Sarcev, Ivan
    [J]. VOJNOSANITETSKI PREGLED, 2013, 70 (05) : 477 - 483
  • [6] Effect of aluminium oxide, titanium oxide, hydroxyapatite filled dental restorative composite materials on physico-mechanical properties
    Yadav, Ramkumar
    Meena, Anoj
    [J]. CERAMICS INTERNATIONAL, 2022, 48 (14) : 20306 - 20314
  • [7] Physico-mechanical properties and fracture characteristics of composite lumber
    Bahari, Shahril Anuar
    Jaafar, Wan Nor Raihan Wan
    [J]. WORLD JOURNAL OF ENGINEERING, 2011, 8 (03) : 217 - 221
  • [8] Physico-mechanical properties of an iron–copper–zinc composite
    L. S. Kokhan
    A. V. Shulgin
    L. M. Semenova
    [J]. Metallurgist, 2010, 54 : 468 - 471
  • [9] Effect of modified nanocellulose on improving mechanical properties of flowable dental composite resin
    Mohammadzadeh, Iman
    Eskandarizadeh, Ali
    Yazdanpanah, Mehrnaz
    Sheibani, Ghazaleh
    Mahmoodi, Moosa
    Nekouei, Amir Hossein
    Alizadeh, Mohammad Javad
    Nejad, Mohaddeseh Shahabi
    Manochehrifar, Hamed
    Sheibani, Hassan
    [J]. INORGANIC CHEMISTRY COMMUNICATIONS, 2024, 161
  • [10] Effect of pH on the physico-mechanical properties of marble
    T. N. Singh
    P. K. Sharma
    Manoj Khandelwal
    [J]. Bulletin of Engineering Geology and the Environment, 2007, 66 : 81 - 87