Ventilators in ICU: A boon or burden

被引:5
|
作者
Mehndiratta, Man Mohan [1 ]
Nayak, Rajeev [3 ]
Ali, Sana [2 ]
Sharma, Ajay [4 ]
Gulati, Natasha Singh [5 ]
机构
[1] Janakpuri Super Special Hosp, Dept Neurol, Janakpuri, India
[2] Janakpuri Super Special Hosp, Dept Microbiol, Janakpuri, India
[3] GB Pant Hosp, Dept Neurol, New Delhi, India
[4] GB Pant Hosp, Dept Neurosurg, New Delhi, India
[5] Inst Liver & Biliary Sci, New Delhi, India
关键词
Healthcare-associated infections (HAI); neurosurgery; ventilator-associated pneumonia (VAP); INTENSIVE-CARE-UNIT; NOSOCOMIAL INFECTIONS; RISK-FACTORS; PNEUMONIA; SURVEILLANCE;
D O I
10.4103/0972-2327.167706
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Aims: Ventilator-associated pneumonia (VAP) is a major challenge in intensive care units (ICUs). This challenge is even more discernible in a neurological setting owing to the predispositions of patients. Data on VAP in the neurology and neurosurgery ICUs (NNICUs) are scanty in developing countries. This study was conducted to find out the occurrence of VAP, its risk factors, microbiological profile, and antibiotic resistance in patients admitted to the NNICU of a tertiary care institute in India. Materials and Methods: Endotracheal aspirate and blood samples were collected from 100 patients admitted to the NNICU. Complete blood count, microscopic examination, culture and sensitivity testing of aspirate were done. Chest x-ray was also performed to aid in the diagnosis of VAP. Results: Incidence rate of VAP was found to be 24%. Acinetobacter baumannii was the most common pathogen (24.3%) isolated from patients with VAP, and all of these isolates were sensitive to meropenem. Duration of mechanical ventilation (P < 0.0001) and associated comorbid illness (P = 0.005) were found to be significantly associated with VAP, and the duration of mechanical ventilation was found to be the only independent risk factor (P < 0.0001). Conclusions: This study highlights the risks and microbiological perspective of ventilator use among neurology patients so that adequate preventive strategies can be adopted on time.
引用
收藏
页码:69 / 73
页数:5
相关论文
共 50 条
  • [1] CHECKLISTS FOR OR AND ICU VENTILATORS
    WETZEL, P
    METZ, G
    SCHMITT, K
    HEIDENREICH, R
    [J]. ANASTHESIE INTENSIVTHERAPIE NOTFALLMEDIZIN, 1984, 19 (02): : 86 - 89
  • [2] THE ICU - BOON OR BANE
    HOWARD, RB
    [J]. POSTGRADUATE MEDICINE, 1982, 72 (01) : 15 - &
  • [3] DISCOVERY: BOON OR BURDEN?
    不详
    [J]. MINNESOTA LAW REVIEW, 1952, 36 (04) : 364 - 382
  • [4] CAL BOON OR BURDEN
    AYSCOUGH, PB
    [J]. CHEMISTRY IN BRITAIN, 1976, 12 (11) : 348 - 352
  • [5] ELECTRICAL APPLIANCES - BURDEN OR BOON
    MCCULLOUGH, JL
    [J]. UTAH SCIENCE, 1978, 39 (01): : 19 - 22
  • [6] CONTAMINATION RATE OF STERILIZED VENTILATORS IN AN ICU
    COMHAIRE, A
    LAMY, M
    [J]. CRITICAL CARE MEDICINE, 1981, 9 (07) : 546 - 548
  • [7] SECONDARY POLYCYTHEMIA - A BOON OR A BURDEN
    ERSLEV, AJ
    CARO, J
    [J]. BLOOD CELLS, 1984, 10 (2-3): : 177 - 191
  • [8] CONTINUOUS-FLOW VENTILATORS IN THE ICU
    MECKLENBURGH, JS
    LATTO, IP
    MAPLESON, WW
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1988, 60 (01) : 118 - 118
  • [9] Wireless technology in the ICU: boon or ban?
    Aviv S Gladman
    Stephen E Lapinsky
    [J]. Critical Care, 11
  • [10] Wireless technology in the ICU: boon or ban?
    Gladman, Aviv S.
    Lapinsky, Stephen E.
    [J]. CRITICAL CARE, 2007, 11 (05):