The impact of patient table on size-specific dose estimate (SSDE)

被引:28
|
作者
Anam, Choirul [1 ,2 ]
Haryanto, Freddy [2 ]
Widita, Rena [2 ]
Arif, Idam [2 ]
Dougherty, Geoff [3 ]
McLean, Donald [4 ]
机构
[1] Diponegoro Univ, Dept Phys, Fac Math & Nat Sci, Semarang 50275, Central Java, Indonesia
[2] Bandung Inst Technol, Dept Phys, Fac Math & Nat Sci, Ganesha 10, Bandung 40132, West Java, Indonesia
[3] CSUCI, Appl Phys & Med Imaging, Camarillo, CA 93012 USA
[4] Canberra Hosp, Med Phys & Radiat Engn, Garran, ACT 2605, Australia
关键词
Water equivalent diameter (D-W); Size-specific dose estimates (SSDE); Volume CT dose index (CTDIVOL); Patient dose; Patient table; ATTENUATION-BASED ESTIMATION; RAY COMPUTED-TOMOGRAPHY; PEDIATRIC CHEST CT; INDEX; IMPLEMENTATION; DIAMETER; MEDICINE; PURPOSE; CANCER; RISKS;
D O I
10.1007/s13246-016-0497-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of parameters water equivalent diameter (D-W) and size-specific dose estimate (SSDE) are becoming increasingly established as a recognised method to relate patient dose from a CT examination to the dose indicator volume CT dose index (CTDIVOL). However, the role of the attenuation due to the patient table in these estimations requires careful consideration and is the subject of this study. The aim of this study is to investigate the impact of a minimal part of the patient table when calculating the D-W and SSDE. We investigated 164 patients who had undergone CT examinations for the pelvis, abdomen, thorax and head. We subsequently calculated D-W and SSDE using two methods: one using a small circular region of interest (ROI) including a minimal part of the patient table and the other using a ROI fitted to the patient border alone. The results showed that the water equivalent diameter calculated with the table included in the ROI (D-W,D- t) is greater, compared to that without the consideration of the patient table (D-W,D- nt), by 1.5-6.2% depending on the anatomy being imaged. On the other hand, the SSDE calculated with inclusion of the patient table (SSDEt) is smaller than otherwise (SSDEnt) by 1.0-5.5% again depending on the anatomy being imaged. The effect of the patient table on D-W and SSDE in the thorax CT examination was statistically significant, but its effect on D-W and SSDE in the other examinations of head, pelvis and abdomen was relatively small and not statistically significant.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [1] The impact of patient table on size-specific dose estimate (SSDE)
    Choirul Anam
    Freddy Haryanto
    Rena Widita
    Idam Arif
    Geoff Dougherty
    Donald McLean
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 153 - 158
  • [2] Feasibility of Using Size-Specific Dose Estimate (SSDE) to Estimate Effective Dose of Individual Patients
    Abuhaimed, A.
    Martin, C.
    Lee, C.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [3] THE SIZE-SPECIFIC DOSE ESTIMATE (SSDE) FOR TRUNCATED COMPUTED TOMOGRAPHY IMAGES
    Anam, Choirul
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 313 - 320
  • [4] Influence of wide beams of CT scans on size-specific dose estimate (SSDE)
    Abuhaimed, A.
    Martin, C. J.
    Demirkaya, O.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S475 - S476
  • [5] Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations
    Moore, B.
    Brady, S.
    Mirro, A.
    Kaufman, R.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 424 - +
  • [6] Exploring the Limits of Size-Specific Dose Estimates (SSDE) as An Estimate of Lung and Breast Dose FromRoutine ChestCT Examinations
    Hardy, A.
    Bostani, M.
    Cagnon, C.
    McNitt-Gray, M.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E189 - E189
  • [7] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Caro Franck
    Charlot Vandevoorde
    Ingeborg Goethals
    Peter Smeets
    Eric Achten
    Koenraad Verstraete
    Hubert Thierens
    Klaus Bacher
    [J]. European Radiology, 2016, 26 : 2646 - 2655
  • [8] Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations
    Moore, Bria M.
    Brady, Samuel L.
    Mirro, Amy E.
    Kaufman, Robert A.
    [J]. MEDICAL PHYSICS, 2014, 41 (07)
  • [9] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Franck, Caro
    Vandevoorde, Charlot
    Goethals, Ingeborg
    Smeets, Peter
    Achten, Eric
    Verstraete, Koenraad
    Thierens, Hubert
    Bacher, Klaus
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (08) : 2646 - 2655
  • [10] Evaluation of a new predictive equation for automated calculation of size-specific dose estimate (SSDE) in CT imaging
    Osman, N. D.
    Abdulkadir, M. K.
    Shuaib, I. L.
    Nasirudin, R. A.
    [J]. RADIOGRAPHY, 2024, 30 (01) : 237 - 244