Baseline Office Building Comparison of GB Standard and ASHRAE Standard in Energy Modeling

被引:0
|
作者
Han, Xing [1 ]
Shi, Ting [1 ]
机构
[1] Shanghai Univ Sci & Technol, Shanghai 201800, Peoples R China
关键词
Office building; Energy-saving standard; EnergyPlus; Baseline building; Simulation; The energy-saving rate;
D O I
10.1007/978-3-642-39578-9_33
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to promote the development of China green building standard and improve the level of building energy efficiency design, in this paper, the two standards, that are China public building energy saving design standard (GB for short) and American ASHRAE 90.1, are compared with the regulations and requirements in baseline building simulation to find out the potential revision part in the China's standard. Take an office building of shanghai for example, the energy consumption is compared between the two baseline buildings which are set based on the above-mentioned standards. The total energy consumption is calculated with energy simulation software EnergyPlus. The calculation results show that the building envelope and equipment efficiency requirements of GB standard are much lower than ASHRAE 90.1, but the average air-conditioning energy consumption is almost the same in two standards, for humidity control is needed in American's air-condition system which increases the reheating energy. The research also demonstrates the lack of energy simulation regulations in GB standard, which are needed to obtain the simulation results more precisely.
引用
收藏
页码:307 / 321
页数:15
相关论文
共 50 条
  • [1] Building energy performance assessment: Comparison between ASHRAE standard 90.1 and Brazilian regulation
    Melo, A. P.
    Sorgato, M. J.
    Lamberts, R.
    [J]. ENERGY AND BUILDINGS, 2014, 70 : 372 - 383
  • [2] ASHRAE Takes on Energy Standard
    Kirkwood, Roderick R.
    [J]. ASHRAE JOURNAL, 2010, 52 (06) : 34 - +
  • [3] ASHRAE ACCEPTS CHALLENGE FOR AN ENERGY STANDARD
    不详
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1974, 16 (05): : 61 - 61
  • [4] OFFICE BUILDING AIR CONDITIONING TO MEET PROPOSED ASHRAE STANDARD 62-1981R.
    Wheeler, Arthur E.
    [J]. ASHRAE Journal, 1988, 30 (07) : 40 - 43
  • [5] BUILDING CONTROLS AND ASHRAE STANDARD 62-1989
    WONG, JW
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1993, 35 (02): : 12 - &
  • [6] Energy Implications of Meeting ASHRAE Standard 62.2
    Walker, Iain S.
    Sherman, Max H.
    [J]. ASHRAE TRANSACTIONS 2008, VOL 114, PT 2, 2008, 114 : 505 - 516
  • [7] OFFICE BUILDING AIR-CONDITIONING TO MEET PROPOSED ASHRAE STANDARD 62-1981R
    WHEELER, AE
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1988, 30 (07): : 40 - 43
  • [8] Correlation analysis of building parameters according to ASHRAE Standard 90.1
    Lee, Kyungjae
    Lim, Hyunwoo
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [9] BUILDING CONTROLS AND ASHRAE STANDARD 62-1989 - REPLY
    PIENTA, WT
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1993, 35 (02): : 51 - 51
  • [10] Impact of WELL Building Standard v2 on the Office Building Energy Performance
    Luo, Jiannan
    Idzikowski, Ines
    Abou Zaki, Anis
    [J]. INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,