Use of the Pentacam True Net Corneal Power for Intraocular Lens Calculation in Eyes After Refractive Corneal Surgery

被引:42
|
作者
Kim, Sang Woo [1 ,5 ]
Kim, Eung Kweon [1 ,2 ]
Cho, Beom-Jin [3 ,4 ]
Kim, Sun Woong
Song, Ki Yung [6 ]
Kim, Tae-im [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Vis Res Inst, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Project Team Nanobiomat Cell Based Implants BK21, Seoul, South Korea
[3] HanGil Eye Hosp, Inchon, South Korea
[4] Ctr Laser, Inchon, South Korea
[5] Soonchunhyang Univ, Bucheon Hosp, Coll Med, Dept Ophthalmol, Puchon, South Korea
[6] Myeong Dong Eye Clin, Seoul, South Korea
关键词
IN-SITU KERATOMILEUSIS; REQUIRING CATARACT-SURGERY; PHOTOREFRACTIVE KERATECTOMY; MYOPIA; FORMULA; PREDICTABILITY; KERATOMETRY; ACCURACY;
D O I
10.3928/1081597X-20090301-08
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the accuracy and validity of true net corneal power of the Pentacam system to provide a keratometry reading for calculating intraocular lens (IOL) power in postoperative refractive surgery eyes. METHODS: Refraction, an automated keratometry reading, and true net corneal power were measured for 30 eyes that required cataract surgery and had previously undergone refractive surgery. Target refraction values calculated with the SRK/T formula using true net corneal power were compared with postoperative manifest refraction values. RESULTS: Using true net corneal power, the mean deviation from the desired postoperative cataract refractive outcome was 0.47+/-0.56 diopters (D); the actual refraction was within +/-0.50 D of the intended refraction for 70% of eyes (21/30) and within +/-1.00 D for 93% of eyes (28/30). CONCLUSIONS: The true net corneal power can be used as a keratometry reading for eyes with previous refractive surgery requiring cataract surgery. [J Refract Surg. 2009;25:285-289.]
引用
收藏
页码:285 / 289
页数:5
相关论文
共 50 条
  • [1] Intraocular lens power calculation in eyes after corneal refractive surgery
    Seitz, B
    Langenbucher, A
    JOURNAL OF REFRACTIVE SURGERY, 2000, 16 (03) : 349 - 361
  • [2] Corneal power estimation for intraocular lens power calculation after corneal laser refractive surgery in Chinese eyes
    Jin, Haiying
    Auffarth, Gerd U.
    Guo, Haike
    Zhao, Peiquan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10): : 1749 - 1757
  • [3] Intraocular lens power calculation using adjusted corneal power in eyes after myopic corneal refractive surgery
    Tan, Qian
    Lin, Ding
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [4] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    EYE AND VISION, 2018, 5
  • [5] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Anders, Philipp
    Anders, Lisa-Marie
    Barbara, Adel
    Szentmary, Nora
    Langenbucher, Achim
    Gatzioufas, Zisis
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2022, 14
  • [6] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Giacomo Savini
    Kenneth J. Hoffer
    Eye and Vision, 5
  • [7] Calculation of intraocular lens power after corneal refractive surgery
    Chan, Colin C. K.
    Hodge, Chris
    Lawless, Michael
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (07): : 640 - 644
  • [8] Intraocular Lens Power Calculation After Corneal Refractive Surgery
    Feiz, Vahid
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2010, 17 (01) : 63 - 68
  • [9] Intraocular lens power calculation after corneal refractive surgery
    Kalyani, Sachin D.
    Kim, Alisa
    Ladas, John G.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (04) : 357 - 362
  • [10] Intraocular lens power calculation after corneal refractive surgery
    Stopyra, Wiktor
    ACTA OPHTHALMOLOGICA, 2024, 102