Investigations of fouling in heat exchangers are mainly focused on two factors: commercial impact due to energy losses, and environmental impact manifested through higher CO2 emissions. The purpose of this paper is to introduce a third factor relating to safety in operations. This paper presents two case studies, one for a hydroprocessing unit with feed/effluent heat exchangers and another for preheat train exchangers installed upstream of the atmospheric furnace in a refinery crude unit. Due to a wide range of process temperatures examined in both case studies, the heat exchangers in the network are subject to various fouling mechanisms. As illustrated in the pictures of actual tube bundles, some of the exchangers within the network are heavily fouled, while the other exchangers operate in nearly clean conditions. Detailed simulations indicate that nonuniform fouling results in heat exchanger operating temperatures that are significantly higher than those predicted by conventional analyses using uniform fouling. Higher than anticipated process fluid temperatures may result in exceeding the threshold limits for certain corrosion mechanisms and/or significantly higher than expected rates of corrosion.
引用
收藏
页码:753 / 761
页数:9
相关论文
共 50 条
  • [1] Optimization of operating conditions for mitigating fouling in heat exchanger networks
    Rodriguez, C.
    Smith, R.
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2007, 85 (A6): : 839 - 851
  • [2] The impact of crystallization fouling on a microscale heat exchanger
    Mayer, Moriz
    Bucko, Juergen
    Benzinger, Walther
    Dittmeyer, Roland
    Augustin, Wolfgang
    Scholl, Stephan
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 40 : 126 - 131
  • [3] Thermal performance of crossflow heat exchanger with nonuniform inlet temperatures
    Kou, HS
    Yuan, P
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1997, 24 (03) : 357 - 370
  • [4] Thermohydraulic Simulation of Heat Exchanger Networks Subjected to Fouling
    Tavares, Viviane B. G.
    Costa, Andre L. H.
    Queiroz, Eduardo M.
    Pessoa, Fernando L. P.
    Liporace, Fabios S.
    Oliveira, Sergio G.
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON PROCESS SYSTEMS ENGINEERING, 2009, 27 : 591 - 596
  • [5] Optimization of Velocity in Heat Exchanger Networks for Fouling Mitigation
    Zhan, Shihui
    Wang, Yufei
    Feng, Xiao
    [J]. PRES15: PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2015, 45 : 61 - 66
  • [6] Exergy Study of Fouling Factors in Heat Exchanger Networks
    Jin, Zunlong
    Dong, Qiwu
    Liu, Minshan
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2010, 132 (01): : 1 - 4
  • [7] Predicting the impact of heat exchanger fouling in power systems
    Qureshi, Bilal Ahmed
    Zubair, Syed M.
    [J]. ENERGY, 2016, 107 : 595 - 602
  • [8] INFLUENCE OF FOULING FACTOR ON THE OPERATING DATA OF A CLEAN HEAT-EXCHANGER
    ZITZMANN, B
    [J]. CHEMIE INGENIEUR TECHNIK, 1990, 62 (02) : 122 - 124
  • [9] Predicting the impact of heat exchanger fouling in refrigeration systems
    Qureshi, Bilal Ahmed
    Zubair, Syed M.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 44 : 116 - 124
  • [10] Fouling in heat exchanger
    不详
    [J]. MATERIALS PERFORMANCE, 2007, 46 (04) : 62 - 62