Early fixation failure of locked plating in complex distal femoral fractures: Root causes analysis

被引:4
|
作者
Hsu, Chun-Liang [1 ,2 ]
Yang, Jui-Jung [1 ,2 ]
Yeh, Tsu-Te [1 ,2 ]
Shen, Hsain-Chung [1 ,2 ]
Pan, Ru-Yu [1 ,2 ]
Wu, Chia-Chun [1 ,2 ]
机构
[1] Triserv Gen Hosp, Dept Orthoped Surg, 325 Cheng Gong Rd,Sect 2, Taipei 114, Taiwan
[2] Natl Def Med Ctr, 325 Cheng Gong Rd,Sect 2, Taipei 114, Taiwan
关键词
Femoral fractures; Fractures; Comminuted; Orthopedics; Risk factors; FEMUR FRACTURES;
D O I
10.1016/j.jfma.2020.06.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Purpose: Orthopaedic Trauma Association (OTA) C-type distal femoral fractures can be very challenging to treat effectively. While locked plating is widely used in the complex distal femoral fracture, failure of locked plate fixation is not uncommon. First, we tried to determine the risk factor related to early failure of multiplanar OTA C-type fracture in the distal femur after fixation with lateral locked plate. Second, we tried to provide a strategy for surgeons to prevent pitfalls of early failure in the complex distal femoral fractures treated with lateral locked plating. Methods: We retrospectively reviewed 44 adults with OTA C-type fractures of the distal femur treated with locked plate fixation between 2010 and 2016 at Tri-Service General Hospital. Average length of follow-up was 27.6 months (range, 12-54 months). Univariate and multivariate logistic regression were used to determine the association of variables on early failure of fixation. A p-value < 0.05 in univariate and multivariate analyses were considered significant. Results: There were six patients experiencing early failure, and the early failure rate was 13.6%. The risk factors associated with early failure of complex distal femoral fracture identified by univariate analysis included sagittal oblique fracture pattern, longer working length and post-operative sagittal malalignment (odds ratio [OR] and 95% confidence intervals [CI]: 90.00 (6.85-1183.33), 0.55 (0.31-0.98) and 8.63 (1.077-69.075) respectively). The multivariate analysis showed only sagittal oblique fracture pattern was associated with early failure [OR: 52.348 (3.06-895.23)]. Conclusion: Sagittal oblique fracture was more likely to result in early postoperative failure. Early recognition of the fracture pattern should be considered to avoid catastrophic results. Copyright (C) 2020, Formosan Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 50 条
  • [1] Minimally invasive fixation of distal femoral fractures using locked plating
    Abdelgaid, Sherif Mohamed
    Verghese, George
    Abou-oof, Alaa
    CURRENT ORTHOPAEDIC PRACTICE, 2013, 24 (05): : 513 - 522
  • [2] Double fixation for complex distal femoral fractures
    Stoffel, Karl
    Sommer, Christoph
    Lee, Mark
    Zhu, Tracy Y.
    Schwieger, Karsten
    Finkemeier, Christopher
    EFORT OPEN REVIEWS, 2022, 7 (04) : 274 - 286
  • [3] Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort
    Hoffmann, Martin F.
    Jones, Clifford B.
    Sietsema, Debra L.
    Tornetta, Paul, III
    Koenig, Scott J.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2013, 8
  • [4] Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort
    Martin F Hoffmann
    Clifford B Jones
    Debra L Sietsema
    Paul Tornetta
    Scott J Koenig
    Journal of Orthopaedic Surgery and Research, 8
  • [5] Comparison of modern locked plating and antiglide plating for fixation of osteoporotic distal fibular fractures
    Switaj, Paul J.
    Wetzel, Robert J.
    Jain, Neel P.
    Weatherford, Brian M.
    Ren, Yupeng
    Zhang, Li-Qun
    Merk, Bradley R.
    FOOT AND ANKLE SURGERY, 2016, 22 (03) : 158 - 163
  • [6] Biomechanical evaluation of locked plating fixation for unstable femoral neck fractures
    Bliven, E.
    Sandriesser, S.
    Augat, P.
    von Rueden, C.
    Hackl, S.
    BONE & JOINT RESEARCH, 2020, 9 (06): : 314 - 321
  • [7] The outcome of Polyax Locked Plating System for fixation distal femoral non-implant related and periprosthetic fractures
    Lampropoulou-Adamidou, Kalliopi
    Tosounidis, Theodoros H.
    Kanakaris, Nikolaos K.
    Ekkernkamp, Axel
    Wich, Michael
    Giannoudis, Peter V.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S18 - S24
  • [8] Double Plating Fixation vs Distal Femoral Replacement in the Management of Distal Femoral Fractures in Geriatric Patients
    Gendya, Amr Gamaleldin Mahmoud Khalil
    El-Zaher, El-Zaher Hassan
    Zakaria, Zeiad Mohamed
    Awad, Mohamed El Sayed
    Metwaly, Radwan Gamal Eldeen Abdelhamid
    ARTHROPLASTY TODAY, 2023, 20
  • [9] Distal Femoral Locking Compression Plate Fixation in Distal Femoral Fractures: Early Results
    Yeap, E. J.
    Deepak, A. S.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2007, 1 (01) : 12 - 17
  • [10] Treatment of complex fractures of the distal radius: A prospective randomised comparison of external fixation 'versus' locked volar plating
    Jeudy, J.
    Steiger, V.
    Boyer, P.
    Cronier, P.
    Bizot, P.
    Massin, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02): : 174 - 179