Mesenteric circulation: Three-dimensional MR angiography with a gadolinium-enhanced multiecho gradient-echo technique

被引:58
|
作者
Shirkhoda, A
Konez, O
Shetty, AN
Bis, KG
Ellwood, RA
Kirsch, MJ
机构
[1] Department of Diagnostic Radiology, William Beaumont Hospital, Royal Oak, MI 48073
关键词
arteries; mesenteric; intestines; MR; magnetic resonance (MR); vascular studies; portal vein; veins;
D O I
10.1148/radiology.202.1.8988220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the mesenteric circulation with magnetic resonance (MR) angiography, the authors examined 16 individuals (12 patients, four volunteers) with a gadolinium-enhanced, breath-hold, fat-saturated, multiecho, three-dimensional, gradient-echo sequence. Twenty examinations were performed. Grades of 3 or 4 (on a five-point scale [4 = best seen, 0 = not seen]) were applicable to 17 (85%) of 20 MR angiograms obtained in superior mesenteric artery trunks, 15 (75%) in celiac arteries, five (25%) in inferior mesenteric arteries; 15 (75%) of first-order branching, 12 (60%) of second-order branching, and 10 (50%) of third-order branching; 17 (85%) in superior mesenteric veins; and 17 (85%) in portal veins. MR angiography with this technique depicted the mesenteric arterial and venous circulation and the portal vein with excellent resolution in a short time.
引用
收藏
页码:257 / 261
页数:5
相关论文
共 50 条
  • [1] Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels
    Gilfeather, M
    Holland, GA
    Siegelman, ES
    Schanll, MD
    Axel, L
    Carpenter, JP
    Golden, MA
    RADIOGRAPHICS, 1997, 17 (02) : 423 - 432
  • [2] Gadolinium-enhanced three-dimensional MR angiography with MR Smart Prep
    Isogai, S
    Takehara, Y
    Isoda, H
    Kodaira, N
    Furutani, K
    Kaneko, M
    RADIOLOGY, 1997, 205 : 1240 - 1240
  • [3] Gadolinium-enhanced three-dimensional MR angiography of the thoracoabdominal aorta
    Krinsky, G
    Weinreb, J
    SEMINARS IN ULTRASOUND CT AND MRI, 1996, 17 (04) : 280 - 303
  • [4] Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography
    Davis, CP
    Hany, TF
    Wildermuth, S
    Schmidt, M
    Debatin, JF
    RADIOGRAPHICS, 1997, 17 (05) : 1061 - 1077
  • [5] Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta
    Prince, MR
    Narasimham, DL
    Jacoby, WT
    Williams, DM
    Cho, KJ
    Marx, MV
    Deeb, GM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) : 1387 - 1397
  • [6] Gadolinium-enhanced three-dimensional MR angiography of Takayasu arteritis
    Nastri, MV
    Baptista, LPS
    Baroni, RH
    Blasbalg, R
    de Avila, LF
    Leite, CC
    de Castro, CC
    Cerri, GG
    RADIOGRAPHICS, 2004, 24 (03) : 773 - 786
  • [7] Gadolinium-enhanced breath-hold three-dimensional MR angiography of the portal vein: Value of the magnetization-prepared rapid acquisition gradient-echo sequence
    Yamashita, Y
    Mitsuzaki, K
    Miyazaki, T
    Namimoto, T
    Sumi, S
    Urata, J
    Abe, Y
    Ogata, I
    Takahashi, M
    RADIOLOGY, 1996, 201 (01) : 283 - 288
  • [8] Three-dimensional gadolinium-enhanced MR angiography: Applications for abdominal imaging
    Glockner, JF
    RADIOGRAPHICS, 2001, 21 (02) : 357 - 370
  • [9] Gadolinium-enhanced three-dimensional MR angiography in jugular phlebectasia and aneurysm
    Fitoz, S
    Atasoy, Ç
    Yagmurlu, A
    Erden, I
    Akyar, S
    CLINICAL IMAGING, 2001, 25 (05) : 323 - 326
  • [10] Use of gadolinium-enhanced, ultrafast, three-dimensional, spoiled gradient-echo magnetic resonance angiography in the preoperative evaluation of living renal allograft donors
    Buzzas, GR
    Shield, CF
    Pay, NT
    Neuman, MJ
    Smith, JL
    TRANSPLANTATION, 1997, 64 (12) : 1734 - 1737