Computerized Adaptive Testing Using the PROMIS Physical Function Item Bank Reduces Test Burden With Less Ceiling Effects Compared With the Short Musculoskeletal Function Assessment in Orthopaedic Trauma Patients

被引:0
|
作者
Hung, Man [1 ]
Stuart, Ami R. [1 ]
Higgins, Thomas F. [1 ]
Saltzman, Charles L. [1 ]
Kubiak, Erik N. [1 ]
机构
[1] Univ Utah, Dept Orthopaed Surg Operat, Salt Lake City, UT 84108 USA
关键词
orthopaedic trauma; PROMIS; PF; computerized adaptive testing; sMFA; INFORMATION-SYSTEM PROMIS; OUTCOMES; QUESTIONNAIRE; VALIDITY;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Patient-reported outcomes are important to assess effectiveness of clinical interventions. For orthopaedic trauma patients, the short Musculoskeletal Function Assessment (sMFA) is a commonly used questionnaire. Recently, the Patient-Reported Outcome Measurement Information System (PROMIS) PF Function Computer Adaptive Test (PF CAT) was developed using item response theory to efficiently administer questions from a calibrated bank of 124 PF questions using computerized adaptive testing. In this study, we compared the sMFA versus the PROMIS PF CAT for trauma patients. Methods: Orthopaedic trauma patients completed the sMFA and the PROMIS PF CAT on a tablet wirelessly connected to the PROMIS Assessment Center. The time for each test administration was recorded. A 1-parameter item response theory model was used to examine the psychometric properties of the instruments, including precision and floor/ceiling effects. Results: One hundred fifty-three orthopaedic trauma patients participated in the study. Mean test administration time for PROMIS PF CAT was 44 seconds versus 599 seconds for sMFA (P < 0.05). Both instruments showed extremely high item reliability (Cronbach alpha = 0.98). In terms of instrument coverage, neither instrument showed any floor effect; however, the sMFA revealed 14.4% ceiling effect, whereas the PROMIS PF CAT had no appreciable ceiling effect. Conclusions: Administered by electronic means, the PROMIS PF CAT required less than one-tenth the amount of time for patients to complete than the sMFA while achieving equally high reliability and less ceiling effects. The PROMIS PF CAT is a very attractive and innovative method for assessing patient-reported outcomes with minimal burden to patients.
引用
收藏
页码:439 / 443
页数:5
相关论文
共 3 条
  • [1] Item Response Theory, Computerized Adaptive Testing, and PROMIS: Assessment of Physical Function
    Fries, James F.
    Witter, James
    Rose, Matthias
    Cella, David
    Khanna, Dinesh
    Morgan-DeWitt, Esi
    JOURNAL OF RHEUMATOLOGY, 2014, 41 (01) : 153 - 158
  • [2] Minimal important change in physical function in trauma patients: a study using the short musculoskeletal function assessment
    M. W. de Graaf
    I. H. F. Reininga
    E. Heineman
    M. El Moumni
    Quality of Life Research, 2020, 29 : 2231 - 2239
  • [3] Minimal important change in physical function in trauma patients: a study using the short musculoskeletal function assessment
    de Graaf, M. W.
    Reininga, I. H. F.
    Heineman, E.
    El Moumni, M.
    QUALITY OF LIFE RESEARCH, 2020, 29 (08) : 2231 - 2239