Bayesian verification of an energy conservation measure

被引:7
|
作者
Lindeloef, David [1 ]
Alisafaee, Mohammad [1 ]
Borso, Pierluca [1 ]
Grigis, Christian [1 ]
Viaene, Jean [1 ]
机构
[1] Neurobat AG, Rue Veyrot 9, CH-1217 Meyrin, Switzerland
关键词
Bayesian inference; Heating degree days; Base temperature; Balance point temperature; Total heat loss coefficient; HVAC-SYSTEMS; BUILDINGS; SAVINGS;
D O I
10.1016/j.enbuild.2018.04.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Most building owners eventually invest in energy conservation measures for their buildings. Faced with a variety of options, ranging from trivial (replacing light bulbs) to major (better facade insulation), they want to know which measure will yield the highest return on investment-and with what confidence. Moreover, once the measure has been applied, they will want to know how well it performs and whether their money was well spent also known as Measurement & Verification (M&V). But conventional M&V mandates the establishment of a baseline. The building should be instrumented during a year or more before applying the measure, driving the costs of M&V to sometimes unacceptable levels. Furthermore, a typical M&V study will report a single number for the measure's efficiency, ignoring any uncertainty surrounding that estimate. To solve these two problems (expensive baseline and absence of uncertainty), we have developed a method, based on Bayesian statistics, that will 1) rely on historic utility bills and climate data to establish the baseline, and 2) estimate, with confidence intervals, how effective the energy conservation measure was. We have tested this method after installing, in March 2016, a model-predictive controller for space heating for a medium-sized (about 2700 m(2)) office building in Switzerland. The baseline was established from historic oil tank refill records and climate data from a nearby weather station. The total heat loss coefficient of the building was assessed 46 days after the installation and found to have decreased by 31.9%, with 17.8 percentage points standard error. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] TRUE MEASURE OF ENERGY CONSERVATION
    不详
    AMERICAN GAS ASSOCIATION MONTHLY, 1974, 56 (11): : 24 - 25
  • [2] Bayesian Energy Measurement and Verification Analysis
    Carstens, Herman
    Xia, Xiaohua
    Yadavalli, Sarma
    ENERGIES, 2018, 11 (02)
  • [3] Measurement and verification of industrial energy conservation projects
    Bhattacharjee, Kaushik, 1600, Bellwether Publishing, Ltd. (33):
  • [4] Conservation of mechanical and electric energy: simple experimental verification
    Ponikvar, D.
    Planinsic, G.
    EUROPEAN JOURNAL OF PHYSICS, 2009, 30 (01) : 47 - 56
  • [5] Parallel Bayesian Belief Network in Building Energy Conservation
    Mirzaei, Golrokh
    Mansouri, Nima
    Jamali, Mohsin M.
    2019 IEEE 62ND INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2019, : 468 - 471
  • [6] Multi-physics model verification based on the law of energy conservation
    Sakura M.
    Sawada K.
    Kaneko O.
    Shin S.
    Matsuda I.
    Murakami T.
    IEEJ Transactions on Electronics, Information and Systems, 2019, 139 (11) : 1293 - 1303
  • [7] MEASUREMENT AND VERIFICATION FOR PERFORMANCE CONTRACT OF HVAC ENERGY CONSERVATION IN HONG KONG
    Fong, K. F.
    Fong, M. L.
    Chow, T. T.
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 120 - 125
  • [8] Bayesian Workflow and Hidden Markov Energy-Signature Model for Measurement and Verification
    Rouchier, Simon
    ENERGIES, 2022, 15 (10)
  • [9] Verification of the Effect of Cross-Ventilation on Energy Conservation by Simulating Occupant Behaviour
    Habara, Hiromi
    Nishizawa, Shigeki
    Miura, Hisashi
    Sawachi, Takao
    Hosoi, Akinori
    INTERNATIONAL JOURNAL OF VENTILATION, 2009, 8 (03) : 265 - 276
  • [10] Virtualisation as conservation measure
    Lurk, Tabea
    ARCHIVING 2008, FINAL PROGRAM AND PROCEEDINGS, 2008, : 221 - 225