Functionalized β-cyclodextrin based potentiometric sensor for naproxen determination

被引:37
|
作者
Lenik, Joanna [1 ]
Lyszczek, Renata [2 ]
机构
[1] Marie Curie Sklodowska Univ, Fac Chem, Dept Analyt Chem & Instrumental Anal, M Curie Sklodowska Sq 3, PL-20031 Lublin, Poland
[2] Marie Curie Sklodowska Univ, Fac Chem, Dept Gen & Coordinat Chem, MC Sklodowska Sq 2, PL-20031 Lublin, Poland
关键词
beta-cyclodextrins; Inclusion complexes with naproxen; IR spectroscopy; Naproxen electrode; Pharmaceutical analysis; ION-SELECTIVE ELECTRODES; INCLUSION COMPLEX; SOLID-CONTACT; IBUPROFEN; CRITERIA; DRUGS; ACID;
D O I
10.1016/j.msec.2015.12.011
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Potentiometric sensors based on neutral 6-cyclodextrins: (2-hydroxypropyl)-beta-cyclodextrin, heptakis(2,3,6-tri-O-methyl)-beta-cyclodextrin, heptakis(2,3,6-tri-O-benzoyl)-beta-cyclodextrin and anionic beta-cyclodextrin: (2-hydroxy-3-N,N,N-trimethylamino)propyl-beta-cyclodextrin chloride for naproxen are described. Inclusion complexes of naproxen with the above-mentioned cyclodextrins were studied using IR spectroscopy. The electrode surface was made from PVC membranes doped with the appropriate beta-cyclodextrin as ionophores and quaternary ammonium chlorides as positive charge additives that were dispersed in plasticizers. The optimum membrane contains heptakis(2,3,6-tri-O-benzoyl)-beta-cyclodextrin, o-nitrophenyloctyl ether and tetraoctyl ammonium chloride as a lipophilic salt. The electrode is characterized by a Nernstian response slope of -59.0 +/- 0.5 mV decade(-1) over the linear range of 5.0 x 10(-5)-1.0 x 10(-2) mol L-1 and the detection limit 1.0 x 10(-5) mol L-1, as well as the response time 10 s. It can be used in the pH range 6.2-8.5 for 10 months without any considerable deterioration. Incorporation of beta-cyclodextrins improved the electrode selectivity towards naproxen ions from several inorganic and organic interferents and some common drug excipients due to concovalent interactions (host molecule-guest molecule). The notable advantages of the naproxen-selective electrode include its high sensitivity, high selectivity, cost-effectiveness as well as accurate and comfortable application in drug analysis and milk samples. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:149 / 157
页数:9
相关论文
共 50 条
  • [1] Potentiometric Sensor for Naproxen Determination
    Zh. Kormosh
    N. Kormosh
    Yu. Bokhan
    N. Gorbatyuk
    I. Kotsan
    S. Suprunovich
    V. Parchenko
    T. Savchuk
    S. Korolchuk
    Pharmaceutical Chemistry Journal, 2021, 55 : 97 - 99
  • [2] Potentiometric Sensor for Naproxen Determination
    Kormosh, Zh
    Kormosh, N.
    Bokhan, Yu
    Gorbatyuk, N.
    Kotsan, I
    Suprunovich, S.
    Parchenko, V
    Savchuk, T.
    Korolchuk, S.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2021, 55 (01) : 97 - 99
  • [3] Cyclodextrin based potentiometric sensor for determination of ibuprofen in pharmaceuticals and waters
    Sousa, T. F. A.
    Amorim, C. G.
    Montenegro, M. C. B. S. M.
    Araujo, A. N.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 660 - 666
  • [4] A Potentiometric Sensor for Ketoprofen Based on a β-Cyclodextrin Derivative
    Lenik, Joanna
    Lyszczek, Renata
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (02) : 246 - 256
  • [5] А Potentiometric Sensor for Ketoprofen Based on a β-Cyclodextrin Derivative
    Journal of Analytical Chemistry, 2022, 77 : 246 - 256
  • [6] β- Cyclodextrin / Carbon Xerogel Based Potentiometric Screen Printed Sensor for Determination of Meclofenoxate Hydrochloride
    Aleem, A. A. Abdul
    Khaled, Elmorsy
    Farghali, Ahmed A.
    Abdelwahab, Abdalla
    Khalil, M. M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (04): : 3365 - 3381
  • [7] Sensitive sequential injection determination of naproxen based on interaction with β-cyclodextrin
    Zisiou, EP
    Pinto, PCAG
    Saraiva, MLMFS
    Siquet, C
    Lima, JLFC
    TALANTA, 2005, 68 (02) : 226 - 230
  • [8] A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticals
    Santini, Alberto O.
    de Oliveira, Jose E.
    Pezza, Helena R.
    Pezza, Leonardo
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2006, 17 (04) : 785 - 791
  • [9] Colorimetric Sensor Based onβ-Cyclodextrin-Functionalized Silver Nanoparticles for Zidovudine Sensitive Determination
    Ghanizadeh Gerayeli, Farhad
    Hosseini, Farnaz
    Bagheri, Zohreh
    Savardashtaki, Amir
    Shabaninejad, Zahra
    Amani, Ali Mohammad
    Najafipour, Sohrab
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 2020
  • [10] A novel sensor for determination of naproxen based on change in localized surface plasmon peak of functionalized gold nanoparticles
    Khodaveisi, Javad
    Shabani, Ali Mohammad Haji
    Dadfarnia, Shayessteh
    Saberi, Dariush
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 179 : 11 - 16