Single detector-based absolute velocity measurement using spectral domain Doppler optical coherence tomography

被引:2
|
作者
Kumar, S. [1 ]
Verma, Y. [1 ]
Sharma, P. [1 ]
Shrimali, R. [1 ]
Gupta, P. K. [1 ]
机构
[1] Raja Ramanna Ctr Adv Technol, Indore 452013, India
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2014年 / 117卷 / 01期
关键词
OCULAR BLOOD-FLOW; ANGLE;
D O I
10.1007/s00340-014-5848-4
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose an approach for absolute velocity measurement where the use of a beam displacer provides two orthogonal linearly polarized beams to probe the sample simultaneously at two different incidence angles. The approach helps remove the cross talk image and facilitates single detector-based Fourier domain Doppler velocity measurement. The system has been characterized by quantifying absolute flow velocity in a flow phantom.
引用
收藏
页码:395 / 399
页数:5
相关论文
共 50 条
  • [1] Single detector-based absolute velocity measurement using spectral domain Doppler optical coherence tomography
    S. Kumar
    Y. Verma
    P. Sharma
    R. Shrimali
    P. K. Gupta
    [J]. Applied Physics B, 2014, 117 : 395 - 399
  • [2] Absolute velocity measurement using three-beam spectral-domain Doppler optical coherence tomography
    P. Sharma
    Y. Verma
    S. Kumar
    P. K. Gupta
    [J]. Applied Physics B, 2015, 120 : 539 - 543
  • [3] Absolute velocity measurement using three-beam spectral-domain Doppler optical coherence tomography
    Sharma, P.
    Verma, Y.
    Kumar, S.
    Gupta, P. K.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2015, 120 (03): : 539 - 543
  • [4] Measurement of the absolute velocity of blood flow in early-stage chick embryos using spectral domain optical coherence tomography
    Ma, Z. -H.
    Ma, Y. -S.
    Zhao, Y. -Q.
    Liu, J.
    Liu, J. -H.
    Lv, J. -T.
    Wang, Y.
    [J]. APPLIED OPTICS, 2017, 56 (31) : 8832 - 8837
  • [5] Phase unwrapping for Doppler spectral domain optical coherence tomography flow measurement
    Zhao, Yuqian
    Ma, Yushu
    Liu, Jian
    Yu, Yao
    Wang, Yi
    Ma, Zhenhe
    [J]. JOURNAL OF BIOPHOTONICS, 2020, 13 (02)
  • [6] Flow Measurement by Lateral Resonant Doppler Optical Coherence Tomography in the Spectral Domain
    Walther, Julia
    Koch, Edmund
    [J]. APPLIED SCIENCES-BASEL, 2017, 7 (04):
  • [7] Lateral resonant Doppler flow measurement by spectral domain optical coherence tomography
    Walther, Julia
    Koch, Edmund
    [J]. OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA II, 2017, 10416
  • [8] An Absolute Detector-based Spectral Radiance Source
    Brown, Steven W.
    Saunders, Robert D.
    Li, Zhigang
    Fein, Abra
    Barnes, Robert A.
    [J]. EARTH OBSERVING SYSTEMS XV, 2010, 7807
  • [9] Quantification of a three-dimensional velocity vector using spectral-domain Doppler optical coherence tomography
    Ahn, Yeh-Chan
    Jung, Woonggyu
    Chen, Zhongping
    [J]. OPTICS LETTERS, 2007, 32 (11) : 1587 - 1589
  • [10] Comment on "Retinal pulse wave velocity measurement using spectral-domain optical coherence tomography"
    Spahr, Hendrik
    Hillmann, Dierck
    Pfaeffle, Clara
    Huettmann, Gereon
    [J]. JOURNAL OF BIOPHOTONICS, 2018, 11 (02)