Comprehensive exergy analysis of a ground-source heat pump system for both building heating and cooling modes

被引:123
|
作者
Bi, Yuehong [1 ,2 ]
Wang, Xinhong [2 ]
Liu, Yun [2 ]
Zhang, Hua [3 ]
Chen, Lingen [1 ]
机构
[1] Naval Univ Engn, Postgrad Sch, Wuhan 430033, Peoples R China
[2] Beijing Univ Technol, Inst Civil & Architectural Engn, Beijing 100124, Peoples R China
[3] Shanghai Univ Sci & Technol, Inst Refrigerat Technol, Shanghai 200093, Peoples R China
关键词
Ground-source heat pump; Building heating and cooling mode; Comprehensive exergy analysis; Exergy indexes; Energy saving; ENTROPY GENERATION MINIMIZATION; PERFORMANCE ASSESSMENT; THERMAL PERFORMANCE; SOLAR; GREENHOUSE; EXCHANGER; ENERGY; THERMODYNAMICS; OPTIMIZATION; SIMULATION;
D O I
10.1016/j.apenergy.2009.04.005
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a comprehensive exergy analysis of three circuits and whole system of a ground-source heat pump (GSHP) for both building heating and cooling modes. The purpose is to search out the key potential energy saving components. The analytical formulae of exergy loss, exergy efficiency, exergy loss ratio, exergy loss coefficient and thermodynamic perfect degree are derived, respectively. The results show that these exergy indexes should be used integratively, and in the whole system the location of maximum exergy loss ratio is the compressor, while the location of minimum exergy efficiency and thermodynamic perfect degree is the ground heat exchanger, so that the compressor and the ground heat exchanger should be primarily improved. The results also indicate that the exergy loss of a GSHP system for building heating mode is bigger than that of cooling mode, and the exergy efficiency of a whole GSHP system is obviously lower than those of its components for both building heating and cooling modes. Therefore, a comprehensive exergy analysis of a GSHP should be paid more attention to. The results may provide guidelines for the design and optimization of GSHP systems. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2560 / 2565
页数:6
相关论文
共 50 条
  • [1] Exergy analysis of a hybrid ground-source heat pump system
    Menberg, Kathrin
    Heo, Yeonsook
    Choi, Wonjun
    Ooka, Ryozo
    Choudhary, Ruchi
    Shukuya, Masanori
    [J]. APPLIED ENERGY, 2017, 204 : 31 - 46
  • [2] Exergy Analysis of a Ground Source Heat Pump System Under Cooling and Heating Conditions
    Zhao, Lei
    Yuan, Chen
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 799 - 806
  • [3] Experiments and exergy analysis for a carbon dioxide ground-source heat pump in cooling mode
    Skye, Harrison M.
    Wu, Wei
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 920 - 937
  • [4] EXERGY ANALYSIS OF A DX GROUND-SOURCE HEAT PUMP SYSTEM IN XIANGTAN, CHINA
    Yang, Wei
    Zhang, Guoqiang
    Zhou, Jin
    Zhang, Peng
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2187 - 2194
  • [5] Thermodynamic analysis of a ground-source heat pump system for district heating
    Hepbasli, A
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2005, 29 (07) : 671 - 687
  • [6] The performance improvements of a ground-coupled heat pump system for both building heating and cooling modes
    Qi, Zishu
    Gao, Qing
    Liu, Yan
    Yan, Y. Y.
    Spitler, Jeffrey D.
    [J]. PROGRESS IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2012, 354-355 : 807 - +
  • [7] Experimental investigation of a ground-source heat pump system for greenhouse heating-cooling
    Harjunowibowo, Dewanto
    Omer, Siddig A.
    Riffat, Saffa B.
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (04) : 1529 - 1541
  • [8] Ground source heat pump carbon emissions and ground-source heat pump systems for heating and cooling of buildings: A review
    Ahmadi, Mohammad Hossein
    Ahmadi, Mohammad Ali
    Sadaghiani, Mirhadi S.
    Ghazvini, Mahyar
    Shahriar, Sadegh
    Nazari, Mohammad Alhuyi
    [J]. ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2018, 37 (04) : 1241 - 1265
  • [9] Ground-source pump system for heating and cooling: Review and thermodynamic approach
    Lucia, Umberto
    Simonetti, Marco
    Chiesa, Giacomo
    Grisolia, Giulia
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 70 : 867 - 874
  • [10] General review of ground-source heat pump systems for heating and cooling of buildings
    Sarbu, Ioan
    Sebarchievici, Calin
    [J]. ENERGY AND BUILDINGS, 2014, 70 : 441 - 454