What is the best proton energy for accelerator-based BNCT using the 7Li(p,n)7Be reaction?

被引:17
|
作者
Allen, DA [1 ]
Beynon, TD [1 ]
机构
[1] Univ Birmingham, Sch Phys & Astron, Birmingham B15 2TT, W Midlands, England
关键词
BNCT; MCNP; accelerator; epithermal neutrons; radiotherapy;
D O I
10.1118/1.598976
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With a growing interest in the use of accelerator-based epithermal neutron sources for BNCT programs, in particular those based upon the Li-7(p,n)Be-7 reaction, there is a need to address the question of "what is the best proton energy to use?" This paper considers this question by using radiation transport calculations to investigate a range of proton energies from 2.15 to 3.5 MeV and a range of moderator sizes. This study has moved away completely from the use of empty therapy beam parameters and instead defines the beam quality and optimizes the moderator design using widely accepted in-phantom treatment planning figures of merit. It is concluded that up to a proton energy of about 2.8 MeV there is no observed variation in the achievable therapy beam quality, but a price is paid in terms of treatment time for not choosing the upper limit of this range. For higher proton energies, the beam quality falls, but with no improvement in treatment time for optimum configurations. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00605-2].
引用
收藏
页码:1113 / 1118
页数:6
相关论文
共 50 条
  • [1] An accelerator-based Boron Neutron Capture Therapy (BNCT) facility based on the 7Li(p,n)7Be
    Musacchio Gonzalez, Elizabeth
    Martin Hernandez, Guido
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 865 : 148 - 151
  • [2] Variations in lithium target thickness and proton energy stability for the near-threshold 7Li(p, n)7Be accelerator-based BNCT
    Kobayashi, Tooru
    Bengua, Gerard
    Tanaka, Kenichi
    Nakagawa, Yoshinobu
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (03): : 645 - 658
  • [3] Beam shaping assembly optimization for 7Li(p,n)7Be accelerator based BNCT
    Minsky, D. M.
    Kreiner, A. J.
    APPLIED RADIATION AND ISOTOPES, 2014, 88 : 233 - 237
  • [4] Optimized therapeutic neutron beam for accelerator-based BNCT by analyzing the neutron angular distribution from 7Li(p,n)7Be reaction
    Kim, Kyung-O
    Kim, Jong Kyung
    Kim, Soon Young
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : 1173 - 1179
  • [5] Feasibility study for accelerator-based intra-operative BNCT using near-threshold 7Li(p,n) 7Be direct neutrons
    Tanaka, K
    Kobayashi, T
    Nakagawa, Y
    Sakurai, Y
    Ishikawa, M
    Hoshi, M
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 213 - 219
  • [6] Near threshold 7Li(p,n) 7Be reaction as neutron source for BNCT
    Minsky, D. M.
    Kreiner, A. J.
    APPLIED RADIATION AND ISOTOPES, 2015, 106 : 68 - 71
  • [7] An AB-BNCT epithermal neutron source using 7Li(p,n)7Be reaction
    Wang, Y. Q.
    Du, J. L.
    Lin, H.
    Zhou, X. Ch.
    Lin, C.
    Qiu, J.
    Li, J. Y.
    Guan, X. C.
    Gu, L.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (03)
  • [8] Characteristics of BDE dependent on 10B concentration for accelerator-based BNCT using near-threshold 7Li(p,n)7Be direct neutrons
    Tanaka, K
    Kobayashi, T
    Bengua, G
    Nakagawa, Y
    Endo, S
    Hoshi, M
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 875 - 879
  • [9] AB-BNCT beam shaping assembly based on 7Li(p,n)7Be reaction optimization
    Minsky, D. M.
    Kreiner, A. J.
    Valda, A. A.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1668 - 1671
  • [10] The validation of the simulation calculation method for the near-threshold 7Li(p,n)7Be and 7Li(p,p'γ)7Li reactions in BNCT
    Kobayashi, T.
    KURRI Progress Report, 2001,