摘要
The clinical biocompatibility and degradation of bioabsorbable interference screws of different polymer composition is described in this report for six patients who underwent repeat arthroscopy after anterior cruciate ligament (ACL) reconstruction. Bioabsorbable interference screws were used for bone plug fixation of bone-patellar tendon-bone (BPTB) autografts. Poly (L-lactide) (PLLA) interference screws were used in one case, poly (D,L-lactide-co-glycolide) (PDLLA-co-PGA) in two cases and poly (D,L-lactide) (PDLLA) in three cases. The patients either underwent removal of the femoral screw or had a biopsy taken from the screw site during re-arthroscopy. Large fragments of the PLLA screw were still present 20 months postoperatively. In one case, the PDLLA-co-PGA screw was extruded spontaneously from the tibial bone tunnel 3 weeks after the operation. In the second PDLLA-co-PGA screw case, there was no evidence left of the screw material on biopsy 12 months after implantation. The PDLLA screw in one patient was removed 6 weeks after implantation without any signs of degradation. No traces of the PDLLA screws were found in the two other patients, 10 or 14 months postoperatively. There were no clinical signs of foreign-body reactions in all cases.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 50 条
  • [1] Successful treatment of scaphoid fractures and nonunions using bioabsorbable screws:: Report of six cases
    Kujala, S
    Raatikainen, T
    Kaarela, O
    Ashammakhi, N
    Ryhänen, J
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (01): : 68 - 73
  • [2] CLINICAL BIOCOMPATIBILITY AND DEGRADATION OF POLYLEVOLACTIDE SCREWS IN THE ANKLE
    BOSTMAN, OM
    PIHLAJAMAKI, HK
    PARTIO, EK
    ROKKANEN, PU
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (320) : 101 - 109
  • [3] Failure strength of bioabsorbable interference screws: effects of in vivo degradation for 12 weeks
    Kilicoglu, O
    Demirhan, M
    Akman, S
    Atalar, AC
    Ozsoy, S
    Ince, U
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (04) : 228 - 234
  • [4] Failure strength of bioabsorbable interference screws: effects of in vivo degradation for 12 weeks
    Onder Kilicoglu
    Mehmet Demirhan
    Senol Akman
    Ata Can Atalar
    Serhat Ozsoy
    Umit Ince
    Knee Surgery, Sports Traumatology, Arthroscopy, 2003, 11 : 228 - 234
  • [5] Evaluation of the degradation of two bioabsorbable interference screws: an in-vivo study in sheep
    Scorsato, Paulo Sergio
    Rahal, Sheila Canevese
    Cestari, Tania Mary
    Mamprim, Maria Jaqueline
    Doiche, Danuta Pulz
    Teixeira, Daniel de Bortoli
    Siqueira, Rafael Cerantola
    Felix, Marcilio
    ACTA CIRURGICA BRASILEIRA, 2022, 37 (04)
  • [6] Sterile pretibial abscess after anterior Cruciate reconstruction from Bioabsorbable interference screws: A report of 2 cases
    Bustield, Benjamin T.
    Anderson, Lesley J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (08): : 911.e1 - 911.e4
  • [7] Comparison of Different Sizes of Bioabsorbable Interference Screws for Anterior Cruciate Ligament Reconstruction Using Bioabsorbable Bead Augmentation in a Porcine Model
    Shen, Pei-Hung
    Lien, Shiu-Bii
    Shen, Hsain-Chung
    Wang, Chih-Chien
    Huang, Guo-Shu
    Chao, Kuo-Hua
    Lee, Chian-Her
    Lin, Leou-Chyr
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (10): : 1101 - 1107
  • [8] A clinical review of bioabsorbable interference screws and their adverse effects in anterior cruciate ligament reconstruction surgery
    Konan, S.
    Haddad, F. S.
    KNEE, 2009, 16 (01): : 6 - 13
  • [9] Biomechanical characteristics of bioabsorbable magnesium-based (MgYREZr-alloy) interference screws with different threads
    Ezechieli, Marco
    Ettinger, Max
    Konig, Carolin
    Weizbauer, Andreas
    Helmecke, Patrick
    Schavan, Robert
    Lucas, Arne
    Windhagen, Henning
    Becher, Christoph
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (12) : 3976 - 3981
  • [10] Biomechanical characteristics of bioabsorbable magnesium-based (MgYREZr-alloy) interference screws with different threads
    Marco Ezechieli
    Max Ettinger
    Carolin König
    Andreas Weizbauer
    Patrick Helmecke
    Robert Schavan
    Arne Lucas
    Henning Windhagen
    Christoph Becher
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3976 - 3981