Nanocomposites of gold nanoparticles and graphene oxide towards an stable label-free electrochemical immunosensor for detection of cardiac marker troponin-I

被引:119
|
作者
Liu, Guozhen [1 ,2 ]
Qi, Meng [1 ]
Zhang, Yin [1 ]
Cao, Chaomin [1 ]
Goldys, Ewa M. [2 ]
机构
[1] Cent China Normal Univ, Coll Chem, Minist Educ, Key Lab Pesticide & Chem Biol, Wuhan 430079, Peoples R China
[2] Macquarie Univ, Dept Phys & Astron, ARC Ctr Excellence Nanoscale Biophoton CNBP, N Ryde, NSW 2109, Australia
基金
中国国家自然科学基金;
关键词
Immunosensors; Graphene oxides; AuNPs; Troponin-I; Ferrocene; ELECTROCHEMILUMINESCENCE IMMUNOSENSOR; MYOCARDIAL INJURY; GLASSY-CARBON; BIOMARKERS; BIOSENSORS; CRYSTAL; IMPACT; ACID;
D O I
10.1016/j.aca.2015.12.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A stable label-free amperometric immunosensor is presented based on gold nanoparticles and graphene oxide nanocomposites for detection of cardiac troponin-I in the early diagnosis of myocardial infarction. For designing of the sensing platform, firstly the nanocomposites based on GO and AuNPs were prepared and anchored on electrode surfaces. The formed nanocomposites provided a platform with big surface area for loading anti-cTnI capture antibody, and worked as a bridge for fast electron transfer subsequently increased the sensitivity. Moreover, the linkages between AuNP, GO, and electrodes were based on covalent bonding by aryldiazonium salt coupling chemistry, which favors the stability of the sensing interface. Finally, the anti-cTnI detection antibody was immobilized on GO tailored with ferrocene molecules, functioning as the signal reporter for the detection of cTnI. The modification process was monitored using electrochemistry, SEM, XPS. The herein immunosensor demonstrates a good selectivity and high sensitivity against human-cTnI, and is capable of detecting cTnI at concentrations as low as 0.05 ng mL(-1), which is 100 times lower than that possible by conventional methods. It is potential to design the portable sensing platform based on AuNPs and GO nanocomposites for future point-of-care diagnostics. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] A label-free electrochemical immunosensor based on gold nanoparticles and graphene oxide for the detection of tumor marker calcitonin
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (19) : 11029 - 11035
  • [2] Label-Free Immunosensor Based on Liquid Crystal and Gold Nanoparticles for Cardiac Troponin I Detection
    Zapp, Eduardo
    Brondani, Daniela
    Silva, Tania Regina
    Girotto, Edivandro
    Gallardo, Hugo
    Vieira, Iolanda Cruz
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [3] Gold nanoparticles mediated label-free capacitance detection of cardiac troponin I
    Bhalla, Vijayender
    Carrara, Sandro
    Sharma, Priyanka
    Nangia, Yogesh
    Suri, C. Raman
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 761 - 768
  • [4] A label-free electrochemical immunosensor for the detection of cardiac marker using graphene quantum dots (GQDs)
    Tuteja, Satish K.
    Chen, Rui
    Kukkar, Manil
    Song, Chung Kil
    Mutreja, Ruchi
    Singh, Suman
    Paul, Ashok K.
    Lee, Haiwon
    Kim, Ki-Hyun
    Deep, Akash
    Suri, C. Raman
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 548 - 556
  • [5] A label-free electrochemical immunosensor based on gold nanoparticles for detection of paraoxon
    Hu, SQ
    Xie, JW
    Xu, QH
    Rong, KT
    Shen, GL
    Yu, RQ
    TALANTA, 2003, 61 (06) : 769 - 777
  • [6] Label-free Electrochemical Immunosensor for Cardiac Troponin T Based on Exfoliated Graphite Nanoplatelets Decorated with Gold Nanoparticles
    Zanato, Nicole
    Talamini, Lucas
    Zapp, Eduardo
    Brondani, Daniela
    Vieira, Iolanda Cruz
    ELECTROANALYSIS, 2017, 29 (07) : 1820 - 1827
  • [7] Porous graphene oxide nanostructure as an excellent scaffold for label-free electrochemical biosensor: Detection of cardiac troponin I
    Kazemi, Sayed Habib
    Ghodsi, Elham
    Abdollahi, Siamak
    Nadri, Samad
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 447 - 452
  • [8] Label-free electrochemiluminescence immunosensor for cardiac troponin I using luminol functionalized gold nanoparticles as a sensing platform
    Li, Fang
    Yu, Yuqi
    Cui, Hua
    Yang, Di
    Bian, Zhiping
    ANALYST, 2013, 138 (06) : 1844 - 1850
  • [9] A label-free electrochemical immunosensor based on an ionic organic molecule and chitosan-stabilized gold nanoparticles for the detection of cardiac troponin T
    Brondani, Daniela
    Piovesan, Jamille Valeria
    Westphal, Eduard
    Gallardo, Hugo
    Dutra, Rosa Amalia Fireman
    Spinelli, Almir
    Vieira, Iolanda Cruz
    ANALYST, 2014, 139 (20) : 5200 - 5208
  • [10] A label-free electrochemical immunosensor based on gold nanoparticles for direct detection of atrazine
    Liu, Xia
    Li, Wen-Jin
    Li, Lei
    Yang, Yang
    Mao, Lu-Gang
    Peng, Zhang
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 408 - 414