A method for calibrating the relative gamma-ray light yield of plastic scintillators

被引:2
|
作者
Mengesha, W. [1 ]
Feng, P. L. [1 ]
Cordaro, J. G. [1 ]
Anstey, M. R. [1 ,2 ]
Myllenbeck, N. R. [1 ]
Throckmorton, D. J. [1 ]
机构
[1] Sandia Natl Labs, 7011 East Ave, Livermore, CA 94550 USA
[2] Davidson Coll, Dept Chem, Davidson, NC 28035 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2017年 / 88卷 / 03期
关键词
ENERGY CALIBRATION; COMPTON EDGE; SPECTROSCOPY; DETECTORS; COUNTERS;
D O I
10.1063/1.4978288
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Currently we are investigating the inclusion of organotin compounds in new polystyrene scintillator materials to improve full gamma-ray energy sensitivity. Accurate calibration of the relative light yield from the newly developed scintillators is crucial to assess merits of compounds and chemical processes used in the scintillators' development. The full energy gamma-ray peak in a measured gamma-ray spectrum is commonly used in calibrating the relative light yield. However, the Compton continuum in the newly developed plastic scintillators is measured with much better efficiency and statistics and is found to be the best spectral feature that can be exploited for expeditious calibration of the relative light yield. In this study, we present a spectral gain matching of measured and simulated spectra, using a spectrum rebinning technique, to determine the Compton edge in a measured Compton continuum for accurate relative light yield calibration. The Compton edges determined using this technique were found to be within 1.2% of their theoretical estimates. Published by AIP Publishing.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] ABSOLUTE YIELD OF LUMINESCENCE OF PLASTIC SCINTILLATORS IN GAMMA-RAY EXCITATION
    ANDREESHCHEV, EA
    ROZMAN, IM
    [J]. OPTIKA I SPEKTROSKOPIYA, 1958, 5 (01): : 39 - 43
  • [2] GAMMA-RAY MEASUREMENTS WITH PLASTIC SCINTILLATORS
    HINE, GJ
    BURROWS, BA
    [J]. RADIATION RESEARCH, 1955, 3 (02) : 234 - 234
  • [3] Bismuth-loaded plastic scintillators for gamma-ray spectroscopy
    Rupert, B. L.
    Cherepy, N. J.
    Sturm, B. W.
    Sanner, R. D.
    Payne, S. A.
    [J]. EPL, 2012, 97 (02)
  • [4] Experimetal facility for studying the light yield of organic scintillators: results of experiment with a gamma-ray source
    Kulik, V. V.
    Gaganov, V. V.
    Dolgopolov, A., V
    Vershinin, I. S.
    Dolinskij, V. Y.
    Temenkov, V. S.
    [J]. JOURNAL OF INSTRUMENTATION, 2020, 15 (12):
  • [5] METHOD FOR DETECTING NONPROPORTIONALITY OF RESPONSE FOR GAMMA-RAY SCINTILLATORS
    PEELLE, RW
    LOVE, TA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1960, 31 (02): : 205 - 206
  • [6] Industrial gamma-ray computed tomography utilizing rod plastic scintillators
    Taheri, Ali
    Askari, Mojtaba
    Biganeh, Ali
    Kochakpour, Javad
    [J]. JOURNAL OF INSTRUMENTATION, 2023, 18 (09)
  • [7] GAMMA RAY MEASUREMENTS WITH PLASTIC SCINTILLATORS
    NARDI, E
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1971, 95 (02): : 229 - &
  • [8] GAMMA-RAY DOSIMETRY WITH ORGANIC SCINTILLATORS
    CARR, RT
    HINE, GJ
    [J]. NUCLEONICS, 1953, 11 (11): : 53 - &
  • [9] Performance of 3D printed plastic scintillators for gamma-ray detection
    Kim, Dong-geon
    Lee, Sangmin
    Park, Junesic
    Son, Jaebum
    Kim, Tae Hoon
    Kim, Yong Hyun
    Pak, Kihong
    Kim, Yong Kyun
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (12) : 2910 - 2917
  • [10] Gamma-ray energy spectrum unfolding of plastic scintillators using artificial neural network
    Heshmati, Khashayar
    Ghal-Eh, Nima
    Najafabadi, Reza Izadi
    Rene Vega-Carrillo, Hector
    [J]. APPLIED RADIATION AND ISOTOPES, 2022, 186