Fabrication and Testing of a Gold Nanoparticle-loaded Tissue-mimicking Phantom for Validation of Gold L-shell X-ray Fluorescence Imaging Results

被引:0
|
作者
Jayarathna, Sandun [1 ]
Ahmed, Md Foiez [1 ]
Cho, Sang Hyun [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
Gold Nanoparticles; X-ray Fluorescence Imaging; Silicon Drift Detector; Gold L-shell X-ray Fluorescence;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We previously reported the development of direct x-ray fluorescence (XRF) imaging system for quantitative imaging of gold nanoparticles (GNPs) on a benchtop setting. This system is implemented with an ordinary polychromatic x-ray source and, by detecting gold L-shell XRF photons, is capable of detecting/imaging trace amounts of gold nanoparticles (GNPs), on the order of partsper-million (ppm), under the calibration conditions. For routine XRF imaging of biological samples (e.g., explanted tumors) containing ppm-level GNPs, this system needs to be tested further under more realistic imaging conditions. Thus, we developed a GNP-loaded tissue-mimicking phantom and performed a phantom imaging study using our benchtop XRF imaging system. For the tissue-mimicking phantom construction, the GNP-filled capillary tubes with known GNP concentrations were placed in an "E" shaped pattern and sandwiched between three layers of cheese. The results (i.e., XRF map) from the scanning of this phantom showed that the "E" shape of the phantom was well visible in the XRF map and all three arms and the stem of "E" were spatially resolved within similar to 2 mm. The measured GNP concentrations were in good agreement with the known GNP concentrations.
引用
收藏
页码:22 / 25
页数:4
相关论文
共 46 条
  • [1] Fabrication and Testing of a Gold Nanoparticle-loaded Tissue-mimicking Phantom for Validation of Gold L-shell X-ray Fluorescence Imaging Results
    Jayarathna, Sandun
    Ahmed, Md Foiez
    Cho, Sang Hyun
    [J]. 2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019, : 92 - 92
  • [2] Validation of Direct Gold L-Shell X-Ray Fluorescence Imaging Results Using a Tissue-Mimicking Phantom Containing Gold Nanoparticles
    Jayarathna, S.
    Ahmed, M. F.
    Cho, S. H.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E192 - E192
  • [3] Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom
    Ren, Liqiang
    Wu, Di
    Li, Yuhua
    Wang, Ge
    Wu, Xizeng
    Liu, Hong
    [J]. MEDICAL PHYSICS, 2014, 41 (03)
  • [4] High-Sensitivity L-Shell X-Ray Fluorescence CT Imaging of Gold
    Bazalova-Carter, M.
    Ahmad, M.
    Xing, L.
    Fahrig, R.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3715 - 3716
  • [5] Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study
    Bazalova-Carter, Magdalena
    Ahmad, Moiz
    Xing, Lei
    Fahrig, Rebecca
    [J]. JOURNAL OF MEDICAL IMAGING, 2015, 2 (04)
  • [6] Development of An Effective Attenuation Correction Method for Gold L-Shell X-Ray Fluorescence Imaging
    Ahmed, M.
    Yasar, S.
    Jayarathna, S.
    Cho, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3290 - 3290
  • [7] Localization and Quantification of Gold Nanoparticles Using L-Shell Fluorescence Imaging with a Benchtop X-Ray Source
    Manohar, N.
    Reynoso, F.
    Cho, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [8] Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source
    Manohar, Nivedh
    Reynoso, Francisco J.
    Cho, Sang Hyun
    [J]. MEDICAL PHYSICS, 2013, 40 (08)
  • [9] Feasibility of Direct L-Shell Fluorescence Imaging of Gold Nanoparticles Using a Benchtop X-Ray Source
    Manohar, N.
    Reynoso, F.
    Cho, S.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3987 - 3988
  • [10] Preliminary Results On Benchtop X-Ray Fluorescence Computed Tomography (XFCT) Imaging of Gold Nanoparticle-Loaded Objects Using a Fully Spectroscopic Pixelated X-Ray Detector
    Ahmed, M. F.
    Jayarathna, S.
    O'Ryan, L.
    Cho, S. H.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E301 - E301