Non-invasive imaging of cardiac electrophysiology in a cardiac resynchronization therapy defibrillator patient with a quadripolar left ventricular lead

被引:13
|
作者
Seger, Michael [1 ]
Hanser, Friedrich [1 ]
Dichtl, Wolfgang [2 ]
Stuehlinger, Markus [2 ]
Hintringer, Florian [2 ]
Trieb, Thomas [3 ]
Pfeifer, Bernhard [1 ]
Berger, Thomas [2 ,4 ]
机构
[1] Univ Hlth Sci Med Informat & Technol UMIT, Inst Elect Elect & Bioengn, A-6060 Hall In Tirol, Austria
[2] Med Univ Innsbruck, Div Cardiol, Dept Internal Med 3, A-6020 Innsbruck, Austria
[3] Med Univ Innsbruck, Dept Radiol 1, A-6020 Innsbruck, Austria
[4] SKA RZ Saalfelden, Ludwig Boltzmann Inst Rehabil Internal Dis, Dept Cardiol, A-5760 Saalfelden, Austria
来源
EUROPACE | 2014年 / 16卷 / 05期
基金
奥地利科学基金会;
关键词
Non-invasive imaging; Electroanatomical mapping; NICE; Cardiac resynchronization therapy; Ventricular activation; HEART-FAILURE; TRIAL; PREEXCITATION; PLACEMENT; MODEL;
D O I
10.1093/europace/euu045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The present study was aimed to assess epi- and endocardial ventricular electroanatomical activation during cardiac resynchronization therapy (CRT) by means of non-invasive imaging of cardiac electrophysiology (NICE) in a patient with a novel quadripolar LV lead. Non-invasive imaging of cardiac electrophysiology is a novel imaging tool which works by fusing data from high-resolution electrocardiogram (ECG) mapping with a model of the patient's individual cardiothoracic anatomy created from magnetic resonance imaging. This was performed in a cardiac resynchronization therapy defribrillator (CRT-D) patient with a quadripolar left ventricular (LV) lead. Beat-to-beat endocardial and epicardial ventricular activation sequences were computed using NICE during intrinsic conduction as well as during different pacing modes with different LV and biventricular (biV) pacing vectors. The spatial resolution of NICE enabled discrimination of the different pacing vectors during LV and biV pacing. Biventricular pacing resulted in a marked shortening of the total activation duration (TAD) of both ventricles when compared with intrinsic conduction and RV and LV pacing. Non-invasive imaging of cardiac electrophysiology facilitates non-invasive imaging of ventricular activation, which may be useful in CRT patients to locate the area of latest ventricular activation as the target area for LV lead placement. Moreover, especially in non-responders to CRT NICE may be further useful to determine the best electrical repositioning option.
引用
收藏
页码:743 / 749
页数:7
相关论文
共 50 条
  • [1] Results of patients with cardiac resynchronization therapy using a quadripolar left ventricular lead
    D'Ortencio, Alfredo
    Bevacqua, Raul J.
    INSUFICIENCIA CARDIACA, 2013, 8 (03) : 142 - 148
  • [2] Outcome of Patients Treated by Cardiac Resynchronization Therapy Using a Quadripolar Left Ventricular Lead
    Bencardino, Gianluigi
    Di Monaco, Antonio
    Russo, Eleonora
    Colizzi, Cristian
    Perna, Francesco
    Pelargonio, Gemma
    Narducci, Maria Lucia
    Gabrielli, Francesca Augusta
    Lanza, Gaetano Antonio
    Rebuzzi, Antonio Giuseppe
    Crea, Filippo
    CIRCULATION JOURNAL, 2016, 80 (03) : 613 - 618
  • [3] Comparison of conventional resynchronization therapy to multipoint pacing using two separate left ventricular leads by non-invasive imaging of cardiac electrophysiology
    Barbieri, Fabian
    Pfeifer, Bernhard
    Berger, Thomas
    Dichtl, Wolfgang
    EUROPEAN HEART JOURNAL, 2015, 36 (46) : 3237 - 3237
  • [4] Echocardiography and non-invasive imaging in cardiac resynchronization therapy
    Delgado, V.
    Mooyaart, E. A. Q.
    Ng, A. Ct
    Auger, D.
    Bertini, M.
    van Bommel, R. J.
    Yiu, K. H.
    Ewe, S. H.
    Witkowski, T. G.
    Marsan, N. Ajmone
    Schuijf, J. D.
    van der Wall, E. E.
    Schalij, M. J.
    Bax, J. J.
    MINERVA CARDIOANGIOLOGICA, 2010, 58 (03): : 313 - 332
  • [5] Non-invasive imaging of cardiac electrophysiology
    Pullan, A
    Paterson, D
    Greensite, F
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2001, 359 (1783): : 1277 - 1286
  • [6] Clinical Usefulness of the Active Fixation Quadripolar Left Ventricular Lead Compared With the Passive Fixation Quadripolar Lead in Cardiac Resynchronization Therapy
    Wakamiya, Akinori
    Ishibashi, Kohei
    Oka, Satoshi
    Miyazaki, Yuichiro
    Ueda, Nobuhiko
    Nakajima, Kenzaburo
    Kamakura, Tsukasa
    Wada, Mitsuru
    Inoue, Yuko
    Miyamoto, Koji
    Nagase, Satoshi
    Aiba, Takeshi
    Kusano, Kengo
    CIRCULATION JOURNAL, 2024, 88 (09) : 1425 - 1431
  • [7] Non-invasive hemodynamic analysis in cardiac resynchronization therapy patients wearing quadripolar left ventricular leads: the importance of pacing electrode selection
    Santini, L.
    Legramante, J. M.
    Condemi, F.
    Santucci, L. M.
    Panattoni, G.
    Crobeddu, P.
    Sergi, D.
    Forleo, G. B.
    Romeo, F.
    MINERVA CARDIOANGIOLOGICA, 2014, 62 (06): : 449 - 459
  • [8] Outcomes of cardiac resynchronization therapy using left ventricular quadripolar leads
    Yang, Mei
    Li, Xuping
    Liang, Jinjun
    Asirvatham, Samuel J.
    Espinosa, Raul
    Li, Yigang
    Friedman, Paul A.
    Cha, Yong-Mei
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (08): : 912 - 919
  • [9] Novel lead anchor technique using an active fixation quadripolar left ventricular lead in cardiac resynchronization therapy
    Inamura, Yukihiro
    Inaba, Osamu
    Sato, Akira
    Nitta, Junichi
    Goya, Masahiko
    Sasano, Tetsuo
    CLINICAL CASE REPORTS, 2022, 10 (02):
  • [10] Ventricular lead position in response to cardiac resynchronization therapy: ECG and non-invasive electrophysiological mapping
    Lubimceva, T.
    Lebedeva, V.
    Zubarev, S.
    Chmelevskiy, M.
    Budanova, M.
    Trukshina, M.
    Lebedev, D.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1173 - 1174