Direct electrochemistry of cytochrome c immobilized on titanium nitride/multi-walled carbon nanotube composite for amperometric nitrite biosensor

被引:99
|
作者
Haldorai, Yuvaraj [1 ,2 ]
Hwang, Seung-Kyu [3 ]
Gopalan, Anantha-Iyengar [4 ]
Huh, Yun Suk [3 ]
Han, Young-Kyu [2 ]
Voit, Walter [1 ,5 ]
Sai-Anand, Gopalan [6 ]
Lee, Kwang-Pill [7 ]
机构
[1] Univ Texas Dallas, Dept Mat Sci & Engn, Richardson, TX 75080 USA
[2] Dongguk Univ Seoul, Dept Energy & Mat Engn, Seoul 100715, South Korea
[3] Inha Univ, Biohybrid Syst Res Ctr BSRC, Dept Biol Engn, Inchon 402751, South Korea
[4] Kyungpook Natl Univ, Res Energy Inst Adv Technol, Daegu 702701, South Korea
[5] Univ Texas Dallas, Alan G MacDiarmid Nanotech Inst, Richardson, TX 75080 USA
[6] Kyungpook Natl Univ, Sch Elect Engn, Daegu 702701, South Korea
[7] Kyungpook Natl Univ, Dept Chem Educ, Daegu 702701, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Carbon nanotubes; Titanium nitride; Nanocomposite; Cytochrome c; Nitrite sensor; MODIFIED ELECTRODE; HYDROGEN-PEROXIDE; OXIDE; FILM; TIN; NANOCOMPOSITE; ELECTROCATALYST; FABRICATION; MYOGLOBIN; PROTEINS;
D O I
10.1016/j.bios.2015.12.054
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this report, titanium nitride (TiN) nanoparticles decorated multi-walled carbon nanotube (MWCNTs) nanocomposite is fabricated via a two-step process. These two steps involve the decoration of titanium dioxide nanoparticles onto the MWCNTs surface and a subsequent thermal nitridation. Transmission electron microscopy shows that TiN nanoparticles with a mean diameter of <= 20 nm are homogeneously dispersed onto the MWCNTs surface. Direct electrochemistry and electrocatalysis of cytochrome c immobilized on the MWCNTs-TiN composite modified on a glassy carbon electrode for nitrite sensing are investigated. Under optimum conditions, the current response is linear to its concentration from 1 PA to 2000 mu M with a sensitivity of 121.5 mu A mu M-1 cm(-2) and a low detection limit of 0.0014 mu M. The proposed electrode shows good reproducibility and long-term stability. The applicability of the as-prepared biosensor is validated by the successful detection of nitrite in tap and sea water samples. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:543 / 552
页数:10
相关论文
共 50 条
  • [1] Direct electrochemistry and electrocatalysis of myoglobin immobilized on zirconia/multi-walled carbon nanotube nanocomposite
    Liang, Ruping
    Deng, Minqiang
    Cui, Sanguan
    Chen, Hong
    Qiu, Jianding
    MATERIALS RESEARCH BULLETIN, 2010, 45 (12) : 1855 - 1860
  • [2] Fabrication and characterization of cytochrome c-immobilized polyaniline/ multi-walled carbon nanotube composite thin film layers for biosensor applications
    Aghamiri, Zahra Sadat
    Mohsennia, Mohsen
    Rafiee-Pour, Hossain-Ali
    THIN SOLID FILMS, 2018, 660 : 484 - 492
  • [3] Direct electrochemistry of cytochrome c and biosensing for hydrogen peroxide on polyaniline grafted multi-walled carbon nanotube electrode
    Lee, Kwang-Pill
    Gopalan, Anantha Iyengar
    Komathi, Shanmugasundaram
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (02) : 518 - 525
  • [4] A reagentless biosensor of nitric oxide based on direct electron transfer process of cytochrome C on multi-walled carbon nanotube
    Zhao, GC
    Yin, ZZ
    Wei, XW
    FRONTIERS IN BIOSCIENCE-LANDMARK, 2005, 10 : 2005 - 2010
  • [5] A novel amperometric biosensor for oxalate determination using multi-walled carbon nanotube-gold nanoparticle composite
    Pundir, C. S.
    Chauhan, Nidhi
    Rajneesh
    Verma, Manjeet
    Ravi
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02): : 796 - 803
  • [6] Immobilization of cytochrome c on polyaniline/polypyrrole/carboxylated multi-walled carbon nanotube/glassy carbon electrode: biosensor fabrication
    Zahra Sadat Aghamiri
    Mohsen Mohsennia
    Hossain-Ali Rafiee-Pour
    Journal of Solid State Electrochemistry, 2019, 23 : 2233 - 2242
  • [7] Immobilization of cytochrome c on polyaniline/polypyrrole/carboxylated multi-walled carbon nanotube/glassy carbon electrode: biosensor fabrication
    Aghamiri, Zahra Sadat
    Mohsennia, Mohsen
    Rafiee-Pour, Hossain-Ali
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2019, 23 (07) : 2233 - 2242
  • [8] Electroanalytical properties of cytochrome c by direct electrochemistry on multi-walled carbon nanotubes incorporated with DNA biocomposite film
    Shie, Jan-Wei
    Yogeswaran, Umasankar
    Chen, Shen-Ming
    TALANTA, 2008, 74 (05) : 1659 - 1669
  • [9] Direct electrochemistry of cytochrome c immobilized on a graphene oxide-carbon nanotube composite for picomolar detection of hydrogen peroxide
    Dinesh, Bose
    Mani, Veerappan
    Saraswathi, Ramiah
    Chen, Shen-Ming
    RSC ADVANCES, 2014, 4 (54) : 28229 - 28237
  • [10] Direct electrochemistry and voltammetric determination of midecamycin at a multi-walled carbon nanotube coated gold electrode
    Wan, Huijun
    Zhao, Faqiong
    Zeng, Baizhao
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 86 (01) : 247 - 250