Estimating the whole-body effective dose and health risks as well as introducing a new easy method for eye lens dosimetry in interventional cardiology procedures

被引:1
|
作者
Hatami, Alireza [1 ]
Bagheri, Mahmoud [2 ,3 ]
Falahati, Farzaneh [1 ]
Banaei, Amin [4 ]
Abedi-Firouzjah, Razzagh [5 ]
Zamani, Hamed [1 ]
Kiapour, Mohammad [6 ]
Momeni, Farideh [7 ]
机构
[1] Shahid Sadoughi Univ Med Sci, Dept Med Phys, Fac Med, Yazd, Iran
[2] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Fac Med, Sina Campus, Tehran, Iran
[4] Tarbiat Modares Univ, Dept Med Phys, Fac Med Sci, Tehran, Iran
[5] Yasuj Univ Med Sci, Cellular & Mol Res Ctr, Yasuj, Iran
[6] Babol Univ Med Sci, Sch Med, Dept Med Phys Radiobiol & Radiat Protect, Babol, Iran
[7] Shiraz Univ Med Sci, Sch Med, Med Phys & Med Engn Dept, Shiraz, Iran
关键词
Dose estimation; Eye lens dosimetry; Whole-body dose; Interventional Cardiology; Cancer risk; ACTIVE PERSONAL DOSIMETERS; RADIOLOGY; RADIATION; CALIBRATION; PHANTOM;
D O I
10.1016/j.mex.2020.101097
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to introduce a new method for eye lens thermo-luminescent dosimetry and also estimate the dose associated with induced cancer risk due to the ionizing radiation exposure received by physicians and other staff cooperating in interventional cardiology (IC) procedures. The measurements were performed with six TLDs (thermoluminescent dosimeters): four TLDs for eye lens dosimetry (2 positioned on respiratory/surgical mask under the eye region as the new method; and 2 near the outside border of the eye as the common method) and two TLDs for whole-body dosimetry. Whole-body doses were used to calculate the cancer risks induced by IC procedures. The results of the new proposed method for eye lens dosimetry were similar to common TLD positioning (mean differences <5%) and mask displacement had no significant effect on eye dose measurement in our new method. Our proposed method for eye lens dosimetry is simpler and more comfortable compared to the common method and it can be used as an alternative method without using TLD holders to monitor lens dose for IC workers wearing masks during the procedure. The estimated excess cancer incidence risk induced by IC procedures was 29.58 +/- 5.71 and 46.68 +/- 7.77 (per 100000 individuals) for men and women, respectively. (C) 2020 The Authors. Published by Elsevier B.V.
引用
收藏
页数:8
相关论文
共 5 条
  • [1] OCCUPATIONAL EYE LENS DOSE ESTIMATED USING WHOLE-BODY DOSEMETER IN INTERVENTIONAL CARDIOLOGY AND RADIOLOGY: A MONTE CARLO STUDY
    Bozovic, Predrag
    Ciraj-Bjelac, Olivera
    Petrovic, Jelena Stankovic
    [J]. RADIATION PROTECTION DOSIMETRY, 2019, 185 (02) : 135 - 142
  • [2] Ratios of Eye Lens and Hand Equivalent Doses with Whole-Body Effective Doses for Operators Performing Interventional Radiological Procedures
    Tsai, Wan-Chih
    Chu, Wei-Han
    Sheu, Rong-Jiun
    [J]. HEALTH PHYSICS, 2022, 123 (03): : 257 - 264
  • [3] Eye lens exposure of nuclear medicine technologists during PET/CT procedures: compliance with dose limits and eye lens vs whole-body dosimetry
    Ryser, M.
    Figueiredo, S.
    Medici, S.
    Prior, J. O.
    Cherbuin, N.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S151 - S151
  • [4] UTILIZING MONTE CARLO SIMULATIONS IN ESTIMATION OF OCCUPATIONAL EYE LENS DOSE BASED ON WHOLE BODY DOSIMETER IN INTERVENTIONAL CARDIOLOGY AND RADIOLOGY
    Bozovic, Predrag M.
    Ciraj-Bjelac, Olivera F.
    Stankovic Petrovic, Jelena S.
    Arandjic, Danijela D.
    Ceklic, Sandra M.
    [J]. NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2018, 33 (04): : 375 - 379
  • [5] Radiobiological risks in terms of effective dose and organ dose from 18F-FDG whole-body PET/CT procedures
    Alameen, Suhaib
    Tamam, Nissren
    Awadain, Sami
    Sulieman, Abdelmoneim
    Alkhaldi, Latifa
    Ben Hmed, Amira
    [J]. SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2021, 28 (10) : 5947 - 5951