Study on Stability of Detection System for the Foreign Matter on the Surface of Analgesic Pump Drug Capsule

被引:0
|
作者
Wang, Dongfeng [1 ,3 ]
Wang, Yongsheng [2 ]
Xu, Rui [3 ]
Su, Jianxiu [3 ]
机构
[1] Henan Tuoren Med Equipment Grp Co Ltd, Changyuan 453003, Peoples R China
[2] Zhumadian Technician Coll, Zhumadian 463000, Peoples R China
[3] Henan Inst Sci & Technol, Xinxiang 453003, Henan, Peoples R China
关键词
D O I
10.1088/1742-6596/1622/1/012058
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A tiny material point and foreign body on the storage bag of an analgesic pump will have a bad influence in clinical use. Therefore, in the production, the surface of the analgesic pump storage bag is tested and effectively removed. There are points and foreign objects are very important steps. In this paper, the stability of the foreign body detection system for the surface of 100 ML analgesic pump storage bag was studied. Experiments show that when N=8, 9, 11, that is, 100ML analgesic pump storage bag is connected with regular octagon, regular pentagonal, positive elliptical, the side length meets the design goal. However, since the time for detecting a single 100ML analgesic pump reservoir at N=8 was less than that for N=9, 11. Therefore, the detection of the 100ML analgesic pump storage bag by N=8 is in line with the production requirements. It provides an experimental reference for the efficiency and quality requirements of analgesia pumps in production.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Detection of Capsule Foreign Matter Defect Based on BP Neural Network
    Wang, Huanhuan
    Liu, Xiaoyu
    Chen, Yi
    2014 IEEE INTERNATIONAL CONFERENCE ON GRANULAR COMPUTING (GRC), 2014, : 325 - 328
  • [2] An Automatic Foreign Matter Detection and Sorting System for PVC Powder
    Chen, Ssu-Han
    Jang, Jer-Huan
    Chang, Yu-Ru
    Kang, Chih-Hsiang
    Chen, Hung-Yi
    Liu, Kevin Fong-Rey
    Lee, Fong-Lin
    Hsueh, Yang-Shen
    Youh, Meng-Jey
    APPLIED SCIENCES-BASEL, 2022, 12 (12):
  • [3] A Pulsed Thermographic Imaging System for Detection and Identification of Cotton Foreign Matter
    Kuzy, Jesse
    Li, Changying
    SENSORS, 2017, 17 (03)
  • [4] An fMRI study of an analgesic drug evaluation system using a Fibromyalgia rat model
    Terasawa, Hiroaki
    Yuzuriha, Naoya
    Takeda, Mitsuhiro
    Yoshinaga, Sosuke
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2017, 133 (03) : S41 - S41
  • [5] Preliminary study of an automatic detection capsule system for gastric occult blood
    Liu, Hongying
    Qiao, Panpan
    Wu, Xueli
    Zhu, Lan
    Pi, Xitian
    Zheng, Xiaolin
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2013, 13 (02) : 105 - 116
  • [6] Microscopic study of paprika (Capsicum annuum L.): detection of fraud and foreign matter
    de Pauli-Yamada, Lais Fernanda
    de Aquino, Cinthia Iara
    da Silva, Augusta Mendes
    Moraes Marciano, Maria Aparecida
    de Mattos, Elaine Cristina
    Nogueira, Marcia Dimov
    VIGILANCIA SANITARIA EM DEBATE-SOCIEDADE CIENCIA & TECNOLOGIA, 2021, 9 (01): : 123 - 128
  • [7] Study on the influence of indoor particulate matter based on orthogonal design in heat pump system
    Dong, Min
    2ND INTERNATIONAL CONFERENCE ON APPLIED MATHEMATICS, MODELLING, AND INTELLIGENT COMPUTING (CAMMIC 2022), 2022, 12259
  • [8] Study on Visual Detection of Foreign Matter in Groove of Zirconium Tube Based on Average Template Method
    Liu J.
    Dong L.
    Suo X.
    Liu, Jian (liujian@hnu.edu.cn), 2020, Hunan University (47): : 53 - 60
  • [9] Pharmacokinetic Study of a Capsule-based Chronomodulated Drug Delivery System of Salbutamol Sulphate in Rabbits
    Qureshi, Mohd Javed
    Ali, Javed
    Baboota, Sanjula
    Ahuja, Alka
    Mallikarjun, Chitneni
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2014, 13 (01) : 17 - 22
  • [10] Study on new condensation heat transfer surface for solar heat pump system
    Wang, Zhongzheng
    Guo, Xinchuan
    Gu, Cao
    Zhao, Zhennan
    Li, Rujun
    Wang, Yan
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 1994, 15 (01): : 57 - 61