Spectral detector CT for cardiovascular applications

被引:59
|
作者
Rajiah, Prabhakar [1 ]
Abbara, Suhny [1 ]
Halliburton, Sandra Simon [2 ]
机构
[1] Southwestern Med Ctr, Dept Radiol, Dallas, TX 75390 USA
[2] Philips Healthcare, Cleveland, OH USA
关键词
DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; METAL ARTIFACTS; IMAGE QUALITY; IODINE LOAD; CARDIAC CT; ANGIOGRAPHY; VOLUME;
D O I
10.5152/dir.2016.16255
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spectral detector computed tomography (SDCT) is a novel technology that uses two layers of detectors to simultaneously collect low and high energy data. Spectral data is used to generate conventional polyenergetic images as well as dedicated spectral images including virtual monoenergetic and material composition (iodine-only, virtual unenhanced, effective atomic number) images. This paper provides an overview of SDCT technology and a description of some spectral image types. The potential utility of SDCT for cardiovascular imaging and the impact of this new technology on radiation and contrast dose are discussed through presentation of initial patient studies performed on a SDCT scanner. The value of SDCT for salvaging suboptimal studies including those with poor contrast-enhancement or beam hardening artifacts through retrospective reconstruction of spectral data is discussed. Additionally, examples of specific benefits for the evaluation of aortic disease, imaging before transcatheter aortic valve implantation, evaluation of pulmonary veins pre- and post-pulmonary radiofrequency ablation, evaluation of coronary artery lumen, assessment of myocardial perfusion, detection of pulmonary embolism, and characterization of incidental findings are presented.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 50 条
  • [1] Spectral detector CT applications in advanced liver imaging
    Majeed, Noor Fatima
    Amirfarzan, Marta Braschi
    Wald, Christoph
    Wortman, Jeremy R.
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1123):
  • [2] Abdominal Applications of a Novel Detector-Based Spectral CT
    Fulton, Nicholas
    Rajiah, Prabhakar
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2018, 47 (02) : 110 - 118
  • [3] SPECTRAL CT WITH A CDTE SEMICONDUCTOR DETECTOR
    Schulze, J.
    Koenig, T.
    Zuber, M.
    Zwerger, A.
    Fauler, A.
    Nill, S.
    Fiederle, M.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S436 - S436
  • [4] Detector-based spectral CT with a novel dual-layer technology: principles and applications
    Rassouli, Negin
    Etesami, Maryam
    Dhanantwari, Amar
    Rajiah, Prabhakar
    INSIGHTS INTO IMAGING, 2017, 8 (06): : 589 - 598
  • [5] Detector-based spectral CT with a novel dual-layer technology: principles and applications
    Negin Rassouli
    Maryam Etesami
    Amar Dhanantwari
    Prabhakar Rajiah
    Insights into Imaging, 2017, 8 : 589 - 598
  • [6] Wide Area Detector CT in Cardiovascular Imaging
    Rybicki, F.
    MEDICAL PHYSICS, 2010, 37 (06) : 3432 - +
  • [7] Spectral performance evaluation of a second-generation spectral detector CT
    Liu, Leening P.
    Shapira, Nadav
    Halliburton, Sandra S.
    Meyer, Sebastian
    Perkins, Amy
    Litt, Harold I.
    Kauczor, Hans Ulrich
    Leiner, Tim
    Stiller, Wolfram
    Noel, Peter B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (04):
  • [8] Spectral μCT with an energy resolving and interpolating pixel detector
    Lohse, L. M.
    Vassholz, M.
    Toepperwien, M.
    Jentschke, T.
    Bergamaschi, A.
    Chiriotti, S.
    Salditt, T.
    OPTICS EXPRESS, 2020, 28 (07) : 9842 - 9859
  • [9] Thoracic Applications of Spectral CT Scan
    Moore, Jonathan
    Remy, Jacques
    Altschul, Erica
    Chusid, Jesse
    Flohr, Thomas
    Raoof, Suhail
    Remy-Jardin, Martine
    CHEST, 2024, 165 (02) : 417 - 430
  • [10] Spectral CT: Current Liver Applications
    Borges, Ana P.
    Antunes, Celia
    Caseiro-Alves, Filipe
    DIAGNOSTICS, 2023, 13 (10)