How does performance of ultrasound tissue typing affect design of prostate IMRT dose-painting protocols?

被引:3
|
作者
Zhang, Pengpeng [1 ]
Osterman, K. Sunshine [1 ]
Liu, Tian [1 ]
Li, Xiang [1 ]
Kessel, Jack [1 ]
Wu, Leester [1 ]
Schiff, Peter [1 ]
Kutcher, Gerald J. [1 ]
机构
[1] Columbia Univ, Med Ctr, Dept Radiat Oncol, New York, NY 10032 USA
关键词
receiver operating characteristic; dose painting; radiation biologic model; treatment planning; prostate cancer;
D O I
10.1016/j.ijrobp.2006.08.061
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate how the performance characteristics of ultrasound tissue typing (UTT) affect the design of a population-based prostate dose-painting protocol. Methods and Materials: The performance of UTT is evaluated using the receiver operating characteristic curve. As the imager's sensitivity increases, more tumors are detected, but the specificity worsens, causing more false-positive results. The UTT tumor map, obtained with a specific sensitivity and specificity setup, was used with the patient's CT image to guide intensity-modulated radiotherapy (IMRT) planning. The optimal escalation dose to the UTT positive region, as well as the safe dose to the negative background, was obtained by maximizing the uncomplicated control (i.e., a combination of tumor control probability and weighted normal tissue complication probability). For high- and low-risk tumors, IMRT plans guided by conventional ultrasound or UTT with a one-dimensional or two-dimensional spectrum analysis technique were compared with an IMRT plan in which the whole prostate was dose escalated. Results: For all imaging modalities, the specificity of 0.9 was chosen to reduce complications resulting from high false-positive results. If the primary tumors were low risk, the IMRT plans guided by all imaging modalities achieved high tumor control probability and reduced the normal tissue complication probability significantly compared with the plan with whole gland dose escalation. However, if the primary tumors were high risk, the accuracy of the imaging modality was critical to maintain the tumor control probability and normal tissue complication probability at acceptable levels. Conclusion: The performance characteristics of an imager have important implications in dose painting and should be considered in the design of dose-painting protocols. (c) 2007 Elsevier Inc.
引用
收藏
页码:362 / 368
页数:7
相关论文
共 11 条
  • [1] How does the performance of ultrasound tissue typing affect the design of prostate IMRT dose painting protocols?
    Zhang, P
    Liu, T
    Osterman, S
    Li, X
    Kessel, J
    Leester, W
    Schiff, P
    Kutcher, GJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S141 - S142
  • [2] Incorporate the imager's performance characteristics into the design of prostate IMRT dose painting protocols
    Zhang, P
    Liu, T
    Osterman, K
    Li, X
    Schiff, P
    Kutcher, G
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1899 - 1899
  • [3] Does Rectal Distention Affect Interfractional Dose to Prostate and Rectum in Prostate IMRT Treatment?: Optimizing IGRT Techniques
    Zhung, J.
    Tien, C.
    Hiatt, J.
    DiPetrillo, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S721 - S721
  • [4] Prospective phase I/II trial of dose-painting prostate brachytherapy guided by cancer-specific ultrasound-based tissue-type imaging (TTI).
    Ennis, Ronald D.
    Trichter, Frieda
    Saigal, Kunal
    Quinn, Stuart A.
    Feleppa, Ernest J.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (04)
  • [5] Phase I/II prospective trial of cancer-specific imaging using ultrasound spectrum analysis tissue-type imaging to guide dose-painting prostate brachytherapy
    Ennis, Ronald D.
    Quinn, S. Aidan
    Trichter, Frieda
    Ryemon, Shannon
    Jain, Anudh
    Saigal, Kunal
    Chandrashekhar, Sarayu
    Romas, Nicholas A.
    Feleppa, Ernest J.
    [J]. BRACHYTHERAPY, 2015, 14 (06) : 801 - 808
  • [6] Determining patient eligibility for prostate IMRT dose painting protocols: The role of image resolution, margin requirements, and intraprostatic tumor volume
    Osterman, K
    Liu, T
    Zhang, P
    Mullokandov, E
    Ennis, R
    Kutcher, G
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1965 - 1965
  • [7] Composite IMRT Planning: How Does the Initial Plan Dose Distribution Affect the Boost Plan Optimization?
    Stathakis, S.
    Avila, G.
    Mavroidis, P.
    Ha, C.
    Eng, T.
    Shi, Z.
    Papanikolaou, P.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 365 - 365
  • [8] Does Helical Tomotherapy Improve Dose Conformity and Normal Tissue Sparing Compared to Conventional IMRT? A Dosimetric Comparison in High Risk Prostate Cancer
    Murthy, V.
    Mallik, S.
    Master, Z.
    Sharma, P. K.
    Mahantshetty, U.
    Shrivastava, S. K.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2011, 10 (02) : 179 - 185
  • [9] Does a delay in low dose rate (LDR) brachytherapy after tissue diagnosis affect outcome for men with low risk prostate cancer?
    Andrews, SF
    Horwitz, EM
    Feigenberg, SJ
    Eisenberg, DF
    Uzzo, RG
    Pollack, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S323 - S323
  • [10] Texture-Based Prostate Cancer Classification on MRI: How Does Inter-Class Size Mismatch Affect Measured System Performance?
    Alfano, R.
    Soetemans, D.
    Bauman, G. S.
    Gaed, M.
    Moussa, M.
    Gomez, J. A.
    Chin, J. L.
    Pautler, S.
    Ward, A. D.
    [J]. MEDICAL IMAGING 2019: COMPUTER-AIDED DIAGNOSIS, 2019, 10950