NEUROFIT: software for fitting Hodgkin-Huxley models to voltage-clamp data

被引:15
|
作者
Willms, AR [1 ]
机构
[1] Univ Canterbury, Biomath Res Ctr, Dept Math & Stat, Christchurch 1, New Zealand
关键词
Hodgkin-Huxley model fitting; computer software; voltage-clamp data; inactivating current;
D O I
10.1016/S0165-0270(02)00227-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
I introduce publicly available software for accurate fitting of Hodgkin-Huxley models to voltage-clamp data. I describe the model and non-linear fitting procedure employed by the software and compare its results with the usual method of fitting such models using potassium A-current data from a pyloric dilator cell of the lobster Panulirus interruptus and sodium current data from an electrocyte cell of the electric fish Sternopygus macrurus. The set of parameter values for the model determined by this software yield current traces that are substantially closer to the observed data than those determined from, the usual fitting method. This improvement is due to the fact that the software fits all of the parameters simultaneously utilizing all of the data rather than fitting steady-state and time constant parameters disjointly using peak currents and portions of the rising and falling phases. I analyze the convergence properties of the software's fitting algorithm using simulated data showing that accurate parameter values are obtained for most of the parameters using any reasonable initial values. The software also incorporates a linear pre-estimation procedure to help in determining reasonable initial values for the full non-linear algorithm. I illustrate and discuss some of the inadequacies of voltage-clamp data. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 150
页数:12
相关论文
共 50 条
  • [1] ON THE INTERPRETATION OF VOLTAGE-CLAMP DATA USING THE HODGKIN-HUXLEY MODEL
    BEAUMONT, J
    ROBERGE, FA
    LEON, LJ
    [J]. MATHEMATICAL BIOSCIENCES, 1993, 115 (01) : 65 - 101
  • [2] ESTIMATION OF THE STEADY-STATE CHARACTERISTICS OF THE HODGKIN-HUXLEY MODEL FROM VOLTAGE-CLAMP DATA
    BEAUMONT, J
    ROBERGE, FA
    LEMIEUX, DR
    [J]. MATHEMATICAL BIOSCIENCES, 1993, 115 (02) : 145 - 186
  • [3] SINUSOIDAL VOLTAGE CLAMP OF THE HODGKIN-HUXLEY MODEL
    FITZHUGH, R
    [J]. BIOPHYSICAL JOURNAL, 1983, 42 (01) : 11 - 16
  • [4] SIGNIFICANCE OF CONDUCTANCES IN HODGKIN-HUXLEY MODELS
    FOSTER, WR
    UNGAR, LH
    SCHWABER, JS
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 1993, 70 (06) : 2502 - 2518
  • [5] Alternative Models to Hodgkin-Huxley Equations
    Deng, Bo
    [J]. BULLETIN OF MATHEMATICAL BIOLOGY, 2017, 79 (06) : 1390 - 1411
  • [6] The impact of Hodgkin-Huxley models on dendritic research
    Petousakis, Konstantinos-Evangelos
    Apostolopoulou, Anthi A.
    Poirazi, Panayiota
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2023, 601 (15): : 3091 - 3102
  • [7] Evaluation of approximate stochastic Hodgkin-Huxley models
    Bruce, Ian C.
    [J]. 2007 3rd International IEEE/EMBS Conference on Neural Engineering, Vols 1 and 2, 2007, : 658 - 662
  • [8] Hodgkin-Huxley type ion channel characterization: An improved method of voltage clamp experiment parameter estimation
    Lee, Jack
    Smaill, Bruce
    Smith, Nicolas
    [J]. JOURNAL OF THEORETICAL BIOLOGY, 2006, 242 (01) : 123 - 134
  • [9] Hodgkin-Huxley and partially coupled inactivation models yield different voltage dependence of block
    Liu, SG
    Rasmusson, RL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (04): : H2013 - H2022
  • [10] An improved parameter estimation method for Hodgkin-Huxley models
    Willms, AR
    Baro, DJ
    Harris-Warrick, RM
    Guckenheimer, J
    [J]. JOURNAL OF COMPUTATIONAL NEUROSCIENCE, 1999, 6 (02) : 145 - 168