Leadless Permanent Pacing: A Single Centre Australian Experience

被引:4
|
作者
Denman, Russell A. [1 ]
Lee, Adam C. [1 ,2 ]
Mengel, Caleb [1 ,2 ]
Townsend, Simon [1 ]
Betts, John [1 ]
Bovey, Nicole [1 ]
Wright, Daniel [1 ]
Davison, Oscar [1 ]
Haqqani, Haris M. [1 ,2 ]
机构
[1] Prince Charles Hosp, Dept Cardiol, Brisbane, Qld, Australia
[2] Univ Queensland, Fac Med, Brisbane, Qld, Australia
来源
HEART LUNG AND CIRCULATION | 2019年 / 28卷 / 11期
关键词
Bradycardia; Heart block; Leadless pacemaker; Atrial fibrillation; PACEMAKER THERAPY; COMPLICATIONS; PERFORMANCE;
D O I
10.1016/j.hlc.2018.09.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background To describe the performance and clinical outcomes of consecutive patients having a leadless pacemaker (LP) implanted at a single institution. Methods Clinical data and device parameters were prospectively collected on all patients undergoing LP implantation from November 2015 to April 2018. Results A total of 79 patients (52 male), median age of 78 years, was included. Leadless pacemaker implantation was successful in 76 patients (96%). Implantation failed in two patients due to excessive venous tortuosity and due to inadequate sensing in another. Seventy-three (73) patients (96%) had chronic atrial fibrillation and all had a Class I or II indication for pacing. Procedure time was 29 minutes (IQR 21-43) and fluoroscopy time was 8 minutes (IQR 5-13). The median R wave at implant was 11.2 mV (IQR 6.9-15.0). The median capture threshold at 0.24 ms was 0.5 V (IQR 0.4-0.9) and impedance was 754 SZ (IQR 680-880). Intraprocedural acute dislodgement occurred in one patient following cutting of the tether but successful snaring and reimplantation was performed. During a median follow-up of 355 days (range 9-905), overall electrical performance has been excellent. No patients have been readmitted for device revision or complications. Five (5) patients (7%) died during follow-up from unrelated causes. Conclusions Leadless pacemakers can be implanted safely and effectively in the majority of patients. Device electrical performance was excellent over a median follow-up of 12 months.
引用
收藏
页码:1677 / 1682
页数:6
相关论文
共 50 条
  • [1] Leadless cardiac pacing: Results from a large single-centre experience
    Lenormand, Thibault
    Abou Khalil, Kassem
    Bodin, Alexandre
    Babuty, Dominique
    Bisson, Arnaud
    Clementy, Nicolas
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2023, 116 (6-7) : 316 - 323
  • [2] Permanent Leadless Cardiac Pacing Results of the LEADLESS Trial
    Reddy, Vivek Y.
    Knops, Reinoud E.
    Sperzel, Johannes
    Miller, Marc A.
    Petru, Jan
    Simon, Jaroslav
    Sediva, Lucie
    de Groot, Joris R.
    Tjong, Fleur V. Y.
    Jacobson, Peter
    Ostrosff, Alan
    Dukkipati, Srinivas R.
    Koruth, Jacob S.
    Wilde, Arthur A. M.
    Kautzner, Josef
    Neuzil, Petr
    CIRCULATION, 2014, 129 (14) : 1466 - 1471
  • [3] Safety and efficacy of leadless pacemaker implant: a single centre experience
    Chipa Casani, F.
    Trucco, M. E.
    Tolosana, J. M.
    Peralta, O.
    Masaferro, S.
    Domingo, R.
    Nunez, R.
    Borras, R.
    Linhart, M.
    Vassanelli, F.
    Arbelo, E.
    Guasch, E.
    Berruezo, A.
    Brugada, J.
    Mont, L.
    EUROPEAN HEART JOURNAL, 2017, 38 : 369 - 369
  • [4] Indications for permanent pacing and pacing mode prescription from 1989 to 2006. Experience of a single academic centre in northern Greece
    Styliadis, Ioannis H.
    Mantziari, Aggeliki P.
    Gouzoumas, Nikolaos I.
    Vassilikos, Vasilios P.
    Paraskevaidis, Stelios A.
    Mochlas, Sotirios T.
    Boufidou, Amalia I.
    Parcharidis, Georgios E.
    HELLENIC JOURNAL OF CARDIOLOGY, 2008, 49 (03) : 155 - 162
  • [5] Pacing parameters and success rates of permanent His-bundle pacing in patients with narrow QRS: a single-centre experience
    Su, Lan
    Wu, Shengjie
    Wang, Songjie
    Wang, Zhengxian
    Xiao, Fangyi
    Shan, Peiren
    Zhou, Hao
    Huang, Zhouqing
    Xu, Lei
    Huang, Weijian
    EUROPACE, 2019, 21 (05): : 763 - 770
  • [6] REAL WORLD EXPERIENCE WITH LEADLESS CARDIAC PACING
    Vaidya, Vaibhav
    Dai, Mingyan
    Asirvatham, Samuel
    Rea, Robert
    Thome, Trena
    Srivathsan, Komandoor
    Mulpuru, Siva
    Kusumoto, Fred
    Venkatachalam, K.
    Ryan, James D.
    Friedman, Paul
    Cha, Yong-Mei
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 482 - 482
  • [7] Pacing in children; Single centre experience of 77 cases
    Dawkins, KD
    Chase, R
    Morgan, JM
    Gnanapragasam, J
    Salmon, AP
    Keeton, BR
    HEART, 1996, 75 (05) : 75 - 75
  • [8] Epicardial pacing wires, a five year, single centre experience
    J Abbas
    K Toombs
    A Zaidi
    JA Hoschtitzky
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [9] 10-year single centre experience with VDD pacing
    Weinbacher, M
    Schaer, B
    Cron, T
    Osswald, S
    EUROPEAN HEART JOURNAL, 2003, 24 : 163 - 163
  • [10] Real-world experience with leadless cardiac pacing
    Vaidya, Vaibhav R.
    Dai, Mingyan
    Asirvatham, Samuel J.
    Rea, Robert F.
    Thome, Trena M.
    Srivathsan, Komandoor
    Mulpuru, Siva K.
    Kusumoto, Fred
    Venkatachalam, Kalpathi L.
    Ryan, James D.
    Friedman, Paul A.
    Cha, Yong-Mei
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (03): : 366 - 373