A Comparative Study of Chromium(III) Ion-Selective Electrodes Based on N,N-Bis(salicylidene)-o-phenylenediaminatechromium(III)

被引:19
|
作者
Abu-Shawish, H. M. [1 ]
Saadeh, S. M. [2 ]
Hartani, K. [1 ]
Dalloul, H. M. [1 ]
机构
[1] Al Aqsa Univ, Fac Sci, Dept Chem, Gaza, Israel
[2] Islam Univ Gaza, Coll Sci, Dept Chem, Gaza, Israel
关键词
Chromium sensor; Potentiometry; Carbon paste electrode; N; N-Bis(salicylidene)-o-phenylenediaminatechromium(III); MODIFIED CARBON-PASTE; POTENTIOMETRIC MEMBRANE SENSOR; CHELATING IONOPHORES; DETECTION LIMITS; TRACE AMOUNTS; SCHIFFS BASE; CR(III); SAMPLES;
D O I
10.1007/BF03246163
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A comparative study was made between three types of Cr(III) ion-selective electrodes: PVC membrane electrode, silver coated electrode and modified carbon paste electrode based on N,N-bis(salicylidene)-o-phenylenediaminatechromium(III) complex (Crsalophen). As anticipated, electrodes with a solid contact, rather than a traditional liquid inner contact, give lower detection limits because of diminished ion fluxes. Often, however, ill-defined solid contact gives rise to instabilities and interferences by oxygen gas. The carbon paste electrode provides a more sensitive and stable device than that afforded by PVC and coated electrodes. The best performance was obtained by an electrode based on the paste containing 3.5 wt% Cr-complex, 48.5% graphite plasticized with a mixture of 24.0 wt% tris(2-ethylhexyl) phosphate (DOPh) + 24.0 wt% dioctyl sebacate (DOS). The sensor has a linear dynamic range of 7.5 x 10(-6) to 1.0 x 10(-2) M, with a Nernstian slope of 20.1 +/- 0.6 mV decade(-1), and a detection limit of 1.8 x 10(-6). It has a short response time of a bout 8 s and is applicable in a pH range of 4.5-7.7. It was successfully used as an indicator electrode in potentiometric titration of Cr(III) with EDTA and in determination of Cr(III) in water samples and chromium in (Crsalophen).
引用
收藏
页码:729 / 737
页数:9
相关论文
共 50 条
  • [1] A comparative study of chromium(III) ion-selective electrodes based on N,N-bis(salicylidene)-o-phenylenediaminatechromium(III)
    H. M. Abu-Shawish
    S. M. Saadeh
    K. Hartani
    H. M. Dalloul
    Journal of the Iranian Chemical Society, 2009, 6 : 729 - 737
  • [2] Holmium(III)-selective fluorimetric optode based on N,N-bis (salicylidene)-naphthylene-1,8-diamine as a neutral fluorogenic ionophore
    Ganjali, Mohammad Reza
    Hosseini, Morteza
    Karimi, Anahita
    Haji-Hashemi, Hedieh
    Salavati-Niasari, Masoud
    Norouzi, Parviz
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 121 : 224 - 229
  • [3] Coated wire chromium(III) ion-selective electrode based on azamacrocycles
    Sil, A
    Ijeri, VS
    Srivastava, AK
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (06) : 1666 - 1669
  • [4] Coated wire chromium(III) ion-selective electrode based on azamacrocycles
    Aparna Sil
    Vijaykumar S. Ijeri
    Ashwini K. Srivastava
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1666 - 1669
  • [5] Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene
    Abbaspour, A
    Izadyar, A
    TALANTA, 2001, 53 (05) : 1009 - 1013
  • [6] An iron(III) ion-selective sensor based on a μ-bis(tridentate) ligand
    Gupta, Vinod K.
    Jain, A. K.
    Agarwal, Shiva
    Maheshwari, Gaurav
    TALANTA, 2007, 71 (05) : 1964 - 1968
  • [7] A novel Al(III)-selective electrochemical sensor based on N,N′-bis(salicylidene)-1,2-phenylenediamine complexes
    Gholivand, M. B.
    Ahmadi, F.
    Rafiee, E.
    ELECTROANALYSIS, 2006, 18 (16) : 1620 - 1626
  • [8] Potentiometric behavior of N,N,N′,N′-tetrabenzylmethylenediamine-based hydrogen ion-selective electrodes
    Cho, DH
    Chung, KC
    Jeong, SS
    Park, MY
    TALANTA, 2000, 51 (04) : 761 - 767
  • [9] INVESTIGATION OF ION-SELECTIVE ELECTRODES BASED ON QUATERNARY PHOSPHONIUM SALTS .2. A TETRACHLOROTHALLATE(III) ION-SELECTIVE ELECTRODE
    KOPYTIN, AV
    GABORKLATSMANYI, P
    IZVEKOV, VP
    PUNGOR, E
    YAGODIN, GA
    ANALYTICA CHIMICA ACTA, 1984, 162 (AUG) : 123 - 132
  • [10] Kinetics and mechanism of the reaction of ranitidine hydrochloride with trans-(diaqua)(N,N′-ethylene-bis-salicylamide) chromium(III) and hexa-aquachromium(III) ion - a comparative study
    Dash, S. C.
    Das, N. N.
    Mohanty, P.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2011, 18 (02) : 132 - 136