Treatment of subtrochanteric fractures.: A comparison of the Gamma nail and the dynamic hip screw:: short-term outcome in 58 patients

被引:45
|
作者
Saarenpaa, I. [1 ]
Heikkinen, T. [1 ]
Jalovaara, P. [1 ]
机构
[1] Univ Oulu, Dept Orthopaed & Trauma Surg, Oulu 90014, Finland
关键词
D O I
10.1007/s00264-006-0088-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this non-randomised prospective study was to evaluate the short-term outcome of Gamma nail and dynamic hip screw (DHS) fixation in the treatment of subtrochanteric hip fractures due to low-energy trauma in the elderly. All of the 1,624 femoral hip fractures in 1,511 patients of the Oulu Hospital, aged over 49 years, were prospectively registered from 1991-1999 using special forms. Seventy-three (4.5%) of the fractures were subtrochanteric. After exclusions, 58 patients constituted the final study group. Of these, 43 were treated with Gamma nails and 15 with DHS. Background factors before the fracture, complications, reoperations and functional parameters at 4 months were recorded using standardised forms. Intraoperative and hospital data were collected from patient records. The Seinsheimer fracture types IIIA, IIC and V were the most common fracture patterns when the Seinsheimer classification system was used, and Fielding II and AO 31A3.3, respectively, were the most common types in the Fielding and AO classification system. There were four (9%) intraoperative complications in the Gamma nail group as compared to none in the DHS group. On the other hand, postoperative complications were more common in the DHS group (27%) than in the Gamma nail group (7%). We recognised a correlation between certain fracture types and the likelihood of typical intra- or postoperative complications or difficulties with both devices: In Gamma nailing, difficulty in closed reduction as well as the rate of open reduction and the use of supplementary fixation were most frequent in the Seinsheimer IIC fractures. It is also noticeable that all of the postoperative device failures and fracture displacements of the DHS group occurred in the Seinsheimer type IIIA category. Detailed fracture classification is essential for the choice of the fixation device, and the present study confirms the presumption that, despite the perioperative problems associated with Gamma nailing, this technique may be preferable to plate fixation for specific fracture types with medial cortical comminution, such as Seinsheimer type IIIA.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 50 条
  • [1] Treatment of subtrochanteric fractures. A comparison of the Gamma nail and the dynamic hip screw: short-term outcome in 58 patients
    I. Saarenpää
    T. Heikkinen
    P. Jalovaara
    [J]. International Orthopaedics, 2007, 31 : 65 - 70
  • [2] Comparison of the Intramedullary Nail and Dynamic Hip Screw in the Treatment of Subtrochanteric Femoral Fractures
    Arshad, Z.
    Thahir, A.
    Rawal, J.
    Hull, P.
    Carrothers, A.
    Krkovic, M.
    Chou, D.
    [J]. BRITISH JOURNAL OF SURGERY, 2021, 108
  • [3] 657 Comparison of the Intramedullary Nail and Dynamic Hip Screw in the Treatment of Subtrochanteric Femoral Fractures
    Arshad, Z.
    Thahir, A.
    Rawal, J.
    Hull, P.
    Carrothers, A.
    Krkovic, M.
    Chou, D.
    [J]. BRITISH JOURNAL OF SURGERY, 2021, 108 (SUPPL 2)
  • [4] Comparison of the Intramedullary Nail and Dynamic Hip Screw in the Management of Subtrochanteric Femoral Fractures
    Arshad, Z.
    Thahir, A.
    Rawal, J.
    Hull, P.
    Carrothers, A.
    Krkovic, M.
    Chou, D. T. S.
    [J]. BRITISH JOURNAL OF SURGERY, 2021, 108
  • [5] Unstable subtrochanteric fractures - gamma nail versus dynamic condylar screw
    Pakuts, AJ
    [J]. INTERNATIONAL ORTHOPAEDICS, 2004, 28 (01) : 21 - 24
  • [6] Unstable subtrochanteric fractures—gamma nail versus dynamic condylar screw
    Andrés J. Pakuts
    [J]. International Orthopaedics, 2004, 28 : 21 - 24
  • [7] THE DYNAMIC HIP SCREW FOR THE TREATMENT OF PERTROCHANTERIC AND SUBTROCHANTERIC FRACTURES OF THE THIGH
    KWASNY, O
    FUCHS, M
    [J]. UNFALLCHIRURG, 1991, 94 (08): : 430 - 435
  • [8] Early mobilisation and long-term results of treatment of trochanteric fractures with the dynamic hip screw and the gamma nail
    Schick, CH
    Wolfel, R
    Walther, M
    Hennig, FF
    [J]. LANGENBECKS ARCHIV FUR CHIRURGIE, 1996, : 991 - 993
  • [9] Sliding hip screw versus IM nail in reverse oblique trochanteric and subtrochanteric fractures. A study of 2716 patients in the Norwegian Hip Fracture Register
    Matre, Kjell
    Havelin, Leif Ivar
    Gjertsen, Jan-Erik
    Vinje, Tarjei
    Espehaug, Birgitte
    Fevang, Jonas Meling
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (06): : 735 - 742
  • [10] Biomechanical comparison of dynamic hip screw and Gamma nail for the treatment of unstable trochanteric fractures: a finite element study
    Huang, Xiaowei
    Yu, Baoqing
    Gu, Yong
    Li, Zexiang
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (05): : 7867 - 7874